This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient im...This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient impedance and dominant transient frequency. The Discrete Fourier Transform (DFT) method is used to determine the dominant transient frequency. The values of voltage and current earth modes are calculated in the period of the dominant transient frequency, then the transient impedance can be determined, from which we can calculate the earth capacitance. The calculated capacitance gives an indication about if the feeder is faulted or not. The algorithm is less dependent on the fault resistance and the faulted feeder parameters; it mainly depends on the background network. The network is simulated by ATP/EMTP program. Several different fault conditions are covered in the simulation process, different fault inception angles, fault locations and fault resistances.展开更多
This paper presents a novel transient current differential algorithm for earth fault detection in unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm uses the transien...This paper presents a novel transient current differential algorithm for earth fault detection in unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm uses the transient residual currents, which are very sensitive for earth faults detection. The transient values of residual currents are calculated for each feeder in the network and used as an earth fault indicator. The flow of residual currents is investigated. It is found that the residual current for the faulted feeder is equal to the summation of all residual currents for all other healthy feedersl Based on this investigation, a differential technique is proposed. A percentage restrain performance is proposed to ensure the selectivity and security of the algorithm. The transient algorithm is very sensitive for earth fault incidence. To apply the proposed algorithm, the residual currents can be measured easily by one sensor for each feeder with no need to voltage measurement. The proposed algorithm is less dependent on the fault resistance and the faulted feeder parameters. The network is simulated by ATP/EMTP program. Different fault conditions are covered in the simulation process: different fault inception angles, fault locations and fault resistances.展开更多
文摘This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient impedance and dominant transient frequency. The Discrete Fourier Transform (DFT) method is used to determine the dominant transient frequency. The values of voltage and current earth modes are calculated in the period of the dominant transient frequency, then the transient impedance can be determined, from which we can calculate the earth capacitance. The calculated capacitance gives an indication about if the feeder is faulted or not. The algorithm is less dependent on the fault resistance and the faulted feeder parameters; it mainly depends on the background network. The network is simulated by ATP/EMTP program. Several different fault conditions are covered in the simulation process, different fault inception angles, fault locations and fault resistances.
文摘This paper presents a novel transient current differential algorithm for earth fault detection in unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm uses the transient residual currents, which are very sensitive for earth faults detection. The transient values of residual currents are calculated for each feeder in the network and used as an earth fault indicator. The flow of residual currents is investigated. It is found that the residual current for the faulted feeder is equal to the summation of all residual currents for all other healthy feedersl Based on this investigation, a differential technique is proposed. A percentage restrain performance is proposed to ensure the selectivity and security of the algorithm. The transient algorithm is very sensitive for earth fault incidence. To apply the proposed algorithm, the residual currents can be measured easily by one sensor for each feeder with no need to voltage measurement. The proposed algorithm is less dependent on the fault resistance and the faulted feeder parameters. The network is simulated by ATP/EMTP program. Different fault conditions are covered in the simulation process: different fault inception angles, fault locations and fault resistances.