期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
射孔作业中管柱受力的有限元分析
1
作者 王哲 胡大裟 蒋玉明 《现代计算机》 2016年第7期6-8,共3页
随着人类对地下石油勘探与开采的需求日益强烈,石油行业对工作人员的技术水平要求越来越严格,而石油开采的环境恶劣、危险性高及其过程的不可预测性,导致进行现场培训可行性差。使用有限元对石油射孔受力系统进行建模分析,可以对射孔过... 随着人类对地下石油勘探与开采的需求日益强烈,石油行业对工作人员的技术水平要求越来越严格,而石油开采的环境恶劣、危险性高及其过程的不可预测性,导致进行现场培训可行性差。使用有限元对石油射孔受力系统进行建模分析,可以对射孔过程中管柱的形变和受力进行模拟,大大提高工程的安全性。 展开更多
关键词 石油射孔 中立点 有限元
下载PDF
An Estimate for Distance Between Adjacent Zeroes of Solutions of Neutral Equations 被引量:2
2
作者 周勇 《Chinese Quarterly Journal of Mathematics》 CSCD 1996年第4期38-43, ,共6页
In this paper, we establish a new estimate for the distance between adjacent zeroes of the solution of the first order neutral differential equation
关键词 neutral equation zeroes ESTIMATE
下载PDF
Oscillation in a Class of Neutral Differential Equations with Positive and Negative Coefficients
3
作者 单文锐 葛渭高 郭彦平 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期321-324,共4页
The oscillatory behavior of neutral differential equation with positive and negative coefficients is investigated by mathematics analysis technique and the fixed point principle. Some sufficient conditions for oscilla... The oscillatory behavior of neutral differential equation with positive and negative coefficients is investigated by mathematics analysis technique and the fixed point principle. Some sufficient conditions for oscillation of neutral differential equation with positive and negative coefficients are obtained. 展开更多
关键词 neutral differential equation OSCILLATION fixed point principle positive and negative coefficients
下载PDF
Application of fractal theory in detecting low current faults of power distribution system in coal mines 被引量:5
4
作者 LIU Jian-hua LIANG Rui WANG Chong-lin FAN Di-peng 《Mining Science and Technology》 EI CAS 2009年第3期321-325,共5页
Single-phase low current grounding faults areoften seen in power distribution system of coal mines.These faults are difficult to reliably identify.We propose a new method of single-phase ground fault protection based ... Single-phase low current grounding faults areoften seen in power distribution system of coal mines.These faults are difficult to reliably identify.We propose a new method of single-phase ground fault protection based upon a discernible matrix of the fractal dimension associated with line currents.The method builds on existing selective protection methods.Faulted feeders are distinguished using differences in the zero-sequence transient current fractal dimension.The current signals were first processed through a fast Fourier transform and then the characteristics of a faulted line were identified using a discernible matrix.The method of calculation is illustrated.The results show that the method involves simple calculations, is easy to do and is highly accurate.It is, therefore, suitable for distribution networks having different neutral grounding modes. 展开更多
关键词 low current faults zero sequence transient current fractal dimension discernible matrix selective protection
下载PDF
A Guide to the Influence of Ground Reaction on Ship Stability
5
作者 Ahmed Helmy Abouelfadl Essam Eldin Youssef Abdelraouf 《Journal of Shipping and Ocean Engineering》 2017年第6期262-273,共12页
Grounded ship faces up exceptionally different stability forces unlike in her normal operating condition. This critical situation must be corrected as soon as can minimize hull stress, the risk of pollution and stabil... Grounded ship faces up exceptionally different stability forces unlike in her normal operating condition. This critical situation must be corrected as soon as can minimize hull stress, the risk of pollution and stability failure. Re-floating the ship need full understanding of the impact of ground reaction (R) on the ship buoyancy and stability. Re-floating the ship has different phases and there are several immediate actions that should be taken by ship's crew; one of these phases is re-calculation of ship stability conditions. In this paper, a guide to understanding the effect of the ground reaction (R), determines the amount of ground pressure and its location. With consideration of the seabed form whether symmetric of asymmetric. Calculating the magnitude of the ground reaction (R) using different applicable methods, explaining the effect of using weight to re-float the ship by her own means, focusing on GM calculation after grounding. 展开更多
关键词 Ship grounding ground reaction (R) ground pressure (P) neutral loading point and ship re-floating.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部