The corrosion causes of rebar in concrete under corrosive environment are analyzed and discussed. It is mainly suffered from the penetration of corrosive species from environment in to the surface of rebar. Corrosio...The corrosion causes of rebar in concrete under corrosive environment are analyzed and discussed. It is mainly suffered from the penetration of corrosive species from environment in to the surface of rebar. Corrosion is initiated by penetration of chlorides and breakdown of passivation, and then propagated by crack of concrete induced by st ress from volume expansion of corrosion product of rebar in succession. Some eff ective countermeasures for corrosion prevention for reinforced concrete are brie fly specified and discussed. Finally, some important techniques commonly used or to be developed are also suggested.展开更多
The complete splitting process of steel fiber reinforced concrete (SFRC) at intermediate strain rate was studied by experiment. The basic information of a self-developed SFRC dynamic test system matching with lnstro...The complete splitting process of steel fiber reinforced concrete (SFRC) at intermediate strain rate was studied by experiment. The basic information of a self-developed SFRC dynamic test system matching with lnstron 1342 materials testing machine was given, and the experiment principle and the loading mode of cubic split specimen were introduced. During the experiment, 30 cubes of 150 mm×150 mm×150 mm and 36 cubes of 100 mm×100 mm×100 mm, designed and prepared according to C20 class SFRC with different volume fractions of steel fiber (0, 1%, 2%, 3%, 4%) were tested and analyzed. At the same time, the size effect of SFRC at intermediate strain rate was investigated. The experimental study indicates that SFRC size effect is not influenced by the loading speed or strain rate. When the steel fiber content increases from 0 to 4%, the splitting strength of SFRC increases from 100% to 261%, i.e. increasing by 161% compared with that of the common concrete. The loading rate increases from 1.33 kN/s to 80.00 kN/s, and the splitting tensile strength increases by 43.55%.展开更多
A review of the current status and progress of steel arch bridges in China is presented in this paper. The existing steel arch bridges in China were analyzed in terms of steel material, span, structure type, main arch...A review of the current status and progress of steel arch bridges in China is presented in this paper. The existing steel arch bridges in China were analyzed in terms of steel material, span, structure type, main arch rib form and construction method. The comparison with CFST arch bridges and RC arch bridges is also conducted. It is shown that steel arch bridge has gain rapid development in China since 2000, characterized by long main spans. As for the span, most of the steel arch bridges have a span less than 250 m, while when the span exceeds 350 m, steel arch bridges are strongly competitive against CFST or RC arch bridges. Over 80% of the bridges are through and half-through bridge types, and the arch ribs are hingeless structures. The rise-to-span ratios of the arches are mainly between 1:4 and 1: 5. Most of the arches use solid box ribs, and a small portion of arches use truss ribs in which box sections are mostly adopted for the truss members. The cantilever method and scaffolding method are the two main construction methods used, but some other construction methods have also been developed.展开更多
文摘The corrosion causes of rebar in concrete under corrosive environment are analyzed and discussed. It is mainly suffered from the penetration of corrosive species from environment in to the surface of rebar. Corrosion is initiated by penetration of chlorides and breakdown of passivation, and then propagated by crack of concrete induced by st ress from volume expansion of corrosion product of rebar in succession. Some eff ective countermeasures for corrosion prevention for reinforced concrete are brie fly specified and discussed. Finally, some important techniques commonly used or to be developed are also suggested.
文摘The complete splitting process of steel fiber reinforced concrete (SFRC) at intermediate strain rate was studied by experiment. The basic information of a self-developed SFRC dynamic test system matching with lnstron 1342 materials testing machine was given, and the experiment principle and the loading mode of cubic split specimen were introduced. During the experiment, 30 cubes of 150 mm×150 mm×150 mm and 36 cubes of 100 mm×100 mm×100 mm, designed and prepared according to C20 class SFRC with different volume fractions of steel fiber (0, 1%, 2%, 3%, 4%) were tested and analyzed. At the same time, the size effect of SFRC at intermediate strain rate was investigated. The experimental study indicates that SFRC size effect is not influenced by the loading speed or strain rate. When the steel fiber content increases from 0 to 4%, the splitting strength of SFRC increases from 100% to 261%, i.e. increasing by 161% compared with that of the common concrete. The loading rate increases from 1.33 kN/s to 80.00 kN/s, and the splitting tensile strength increases by 43.55%.
文摘A review of the current status and progress of steel arch bridges in China is presented in this paper. The existing steel arch bridges in China were analyzed in terms of steel material, span, structure type, main arch rib form and construction method. The comparison with CFST arch bridges and RC arch bridges is also conducted. It is shown that steel arch bridge has gain rapid development in China since 2000, characterized by long main spans. As for the span, most of the steel arch bridges have a span less than 250 m, while when the span exceeds 350 m, steel arch bridges are strongly competitive against CFST or RC arch bridges. Over 80% of the bridges are through and half-through bridge types, and the arch ribs are hingeless structures. The rise-to-span ratios of the arches are mainly between 1:4 and 1: 5. Most of the arches use solid box ribs, and a small portion of arches use truss ribs in which box sections are mostly adopted for the truss members. The cantilever method and scaffolding method are the two main construction methods used, but some other construction methods have also been developed.