基于激光干涉法的谐振式高加速度振动传感器校准技术研究
1
作者 王红杰 蔡晨光 +3 位作者 刘志华 孔明 郭天太 赵焕兴 《激光杂志》 CAS 北大核心 2021年第2期10-15,共6页
校准是保证振动传感器测量结果准确和可靠的重要手段。针对传统中频校准装置无法提供高加速度振动激励以及高加速度振动量值无法溯源的问题,开展基于激光干涉法的谐振式高加速度振动传感器校准技术研究。基于谐振原理建立谐振式高加速... 校准是保证振动传感器测量结果准确和可靠的重要手段。针对传统中频校准装置无法提供高加速度振动激励以及高加速度振动量值无法溯源的问题,开展基于激光干涉法的谐振式高加速度振动传感器校准技术研究。基于谐振原理建立谐振式高加速度振动发生装置,实现高加速度振动发生;建立外差激光干涉法绝对振动校准系统,通过对外差激光干涉信号的直接采集和解调,实现了高加速度振动测量和校准。实验结果表明,该系统能够在140-2929 Hz频率范围、100-10000 m/s^(2)加速度范围内实现振动传感器的灵敏度幅值与相位的有效校准。 展开更多
关键词 振动校准 激光干涉法 高加速度 中频范围 量值溯源
下载PDF
Low impedance nature of 12 acupoints on the limbs,and the unexpected dependence on limb angle 被引量:1
2
作者 Xu Jingjing Yang Fan +4 位作者 Han Danhong Wang Zhenhai Hong Yuankai Han Hongbin Xu Shengyong 《Journal of Traditional Chinese Medicine》 SCIE CAS CSCD 2018年第2期287-298,共12页
OBJECTIVE: To better understand the working mechanism of acupuncture, we investigated the skin electrical impedance distribution around acupoints, and the impedance changes at 12 original acupoints bilaterally after b... OBJECTIVE: To better understand the working mechanism of acupuncture, we investigated the skin electrical impedance distribution around acupoints, and the impedance changes at 12 original acupoints bilaterally after bending the limbs.METHODS: We measured the skin electrical impedance in three study subjects in the frequency range of 40 to 10 k Hz using the four-electrode method with a sharp probe and a large reference electrode.A measurement matrix of 7 mm × 7 mm with spacing of 2.0(or 3.0) mm was measured to obtain 2 D impedance mapping of acupoints. The impedance spectra of 12 original acupoints were measured at the 0° position and the 90° position.RESULTS: The electrical impedance of some acupoints, such as Yangchi(TE 4), was 16 times lower than that of the surrounding area, showing a recognizable small central area of low impedance with a diameter of less than 4 mm. In contrast, other acupoints, such as Laogong(PC 8), had an electrical impedance that was not significantly different from that of the surrounding area. When the limb was bent from a straight position(0o) to a vertical position(90o), the electrical impedance of the 12 original acupoints showed varied trends, either increasing or decreasing by a factor of up to ten times, or remaining at the same level.CONCLUSION: Not all acupoints tested show the property of low impedance, which might be related to the varied depth of the openings of superficial collaterals. The unexpected dependence of acupoint impedance on limb angle is a novel discovery, which implies that the channel paths are located in interstitial structures in the limbs. It might be possible to determine an optimized limb position for each particular acupuncture treatment in clinical practice. 展开更多
关键词 Channel ACUPOINT Superficial collater-als Electric impedance LIMB
原文传递