期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Sysmex CHEMIX-180全自动临床生化分析仪
1
《常规医疗装备》 2004年第3期28-28,共1页
关键词 SYSMEX CHEMIX-180全自动临床生化分析仪 程序设计 数据管理 试剂
下载PDF
如何选购全自动生化分析仪
2
作者 侯卫红 《新疆医学》 2011年第11期53-54,共2页
全自动生化分析仪(简称ACA)已广泛应用于各级医院中。临床生化自动分析仪的规格型号很多,生产厂也很多,随着技术的革新和应用的要求,在性能和结构上都有了很大改进和发展。不同等级的医院因临床需要和科研任务不同。
关键词 自动生化分析仪 临床生化自动分析仪 选购 生产厂 医院 应用
下载PDF
全自动生化分析仪的部分故障分析与排除 被引量:3
3
作者 周敏 《中国卫生检验杂志》 CAS 2010年第9期2351-2351,共1页
关键词 自动临床生化分析仪 报警
原文传递
Two clinically relevant pressures of carbon dioxide pneumoperitoneum cause hepatic injury in a rabbit model 被引量:10
4
作者 Jun Li Ying-Hai Liu +3 位作者 Zhan-Yong Ye He-Nian Liu Shan Ou Fu-Zhou Tian 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第31期3652-3658,共7页
AIM:To observe the hepatic injury induced by carbon dioxide pneumoperitoneum(CDP) in rabbits,compare the eects olow-and high-pressure pneumoperitoneum,and to determine the degree o hepatic injury induced by these two ... AIM:To observe the hepatic injury induced by carbon dioxide pneumoperitoneum(CDP) in rabbits,compare the eects olow-and high-pressure pneumoperitoneum,and to determine the degree o hepatic injury induced by these two clinically relevant CDP pressures.METHODS:Thirty healthy male New Zealand rabbits weighing 3.0 to 3.5 kg were randomly divided into three groups(n = 10 for each group) and subjected to the ollowing to CDP pressures:no gas control,10 mmHg,or 15 mmHg.Histological changes in liver tissues were observed with hematoxylin and eosin staining and transmission electron microscopy.Liver unction was evaluated using an automatic biochemical analyzer.Adenine nucleotide translocator(ANT) activity in liver tissue was detected with the atractyloside-inhibitor stop technique.Bax and Bcl-2 expression levels were detected bywestern blotting.RESULTS:Liver Functions in the 10 mmHg and 15 mmHg experimental groups were significantly disturbed compared with the control group.After CDP,the levels or alanine transaminase and aspartate transaminase were 77.3 ± 14.5 IU/L and 60.1 ± 11.4 IU/L,respectively,in the 10 mmHg experimental group and 165.1 ± 19.4 IU/L and 103.8 ± 12.3 IU/L,respectively,in the 15 mmHg experimental group,which were all higher than those of the control group(p < 0.05).There was no difference in pre-albumin concentration between the 10 mmHg experimental group and the control group,but the prealbumin level of the 15 mmHg experimental group was significantly lower than that of the control group(p < 0.05).No significant differences were observed in the levels of total bilirubin or albumin among the three groups.After 30 and 60 min of CDP,pH was reduced(p < 0.05) and fa CO2 was elevated(p < 0.05) in the 10 mmHg group compared with controls,and these changes were more pronounced in the 15 mmHg group.Hematoxylin and eosin staining showed no significant change in liver morphology,except for mild hyperemia in the two experimental groups.Transmission electron microscopy showed mild mitochondrial swelling in hepatocytes of the 10 mmHg group,and this was more pronounced in the 15 mmHg group.No significant difference in ANT levels was found between the control and 10 mmHg groups.However,ANT concentration was significantly lower in the 15 mmHg group compared with the control group.The expression of hepatic Bax was significantly increased in the two experimental groups compared with the controls,but there were no differences in Bcl-2 levels among the three groups.Twelve hours after CDP induction,the expression of hepatic Bax was more significant in the 15 mmHg group than in the 10 mmHg group.CONCLUSION:A CDP pressure of 15 mmHg caused more substantial hepatic injury,such as increased levels of acidosis,mitochondrial damage,and apoptosis;therefore,10 mmHg CDP is preferable for laparoscopic operations. 展开更多
关键词 Carbon dioxide pneumoperitoneum Hepatic injury RABBIT MITOCHONDRIA APOPTOSIS
下载PDF
血清ALT紫外监测法试剂盒的研制和应用
5
作者 沈伽弟 《军事医学》 CAS CSCD 北大核心 1989年第4期277-281,共5页
作者采用国产原料研制成功适用于在临床生化自动分析仪或紫外分光光度计上测定血清ALT(GPT)活性的ALT紫外监测法试剂盒.在Impact400型生化仪上所作的试剂盒性能质量评价实验证明,酶促反应的延迟时间短(<20s),批内变异系数1.1~6.5%,... 作者采用国产原料研制成功适用于在临床生化自动分析仪或紫外分光光度计上测定血清ALT(GPT)活性的ALT紫外监测法试剂盒.在Impact400型生化仪上所作的试剂盒性能质量评价实验证明,酶促反应的延迟时间短(<20s),批内变异系数1.1~6.5%,血清ALT活性线性可达1000u/L(37℃),与进口同类试剂盒对比测定结果一致,呈非常显著相关.自制ALT试剂盒4~8℃存放可稳定6个月.81名健康成人血清ALT活性为26.91±8.91u/L(37℃). 展开更多
关键词 丙氨酸氨基移换酶(谷丙转氨酶) 紫外监测法 临床生化自动分析仪 试剂盒
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部