To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current i...To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current inverter to generate compensating currents and injecting the currents directly into the DC side of the system,the grid-side currents of the rectifier can be approximated to sine wave.Using zigzag autotransformer as phase-shifting transformer can block the zero sequence current components and reduce the equivalent capacity of the rectifying system.The study on harmonic distortion rate of grid-side currents with the variation of the load shows that the harmonic content of the compensated rectifier decreases significantly under various load conditions.The harmonic content of the grid-side currents of the proposed active injection rectifier is only 1.17%,and the equivalent capacity of the rectifier is calculated.The results show that the rectifier can not only suppress the harmonic currents,but also have a lower equivalent capacity.展开更多
基金National Natural Science Foundation of China(No.51767013)Science and Technology Research and Development Plan of China Railway Corporation(No.2017J012-A)Lanzhou City Science and Technology Program for Innovation and Entrepreneurship of Talents(No.2017-RC-51)。
文摘To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current inverter to generate compensating currents and injecting the currents directly into the DC side of the system,the grid-side currents of the rectifier can be approximated to sine wave.Using zigzag autotransformer as phase-shifting transformer can block the zero sequence current components and reduce the equivalent capacity of the rectifying system.The study on harmonic distortion rate of grid-side currents with the variation of the load shows that the harmonic content of the compensated rectifier decreases significantly under various load conditions.The harmonic content of the grid-side currents of the proposed active injection rectifier is only 1.17%,and the equivalent capacity of the rectifier is calculated.The results show that the rectifier can not only suppress the harmonic currents,but also have a lower equivalent capacity.