期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
甲状腺、乳腺重复癌1例
1
作者 马友龙 丁双剑 祁海艳 《山东医药》 CAS 北大核心 2011年第28期106-106,共1页
患者女,49岁,因发现颈前肿物6个月于2010年12月13日入院。入院查体:意识清,精神好,巩膜无黄染,颈软无抵抗,颈动脉搏动正常,肝颈静脉回流征阴性。右侧颈部可及一约5.0 cm×4.0 cm肿物,表面光滑、边界清、随吞咽上下运动,左侧未触及... 患者女,49岁,因发现颈前肿物6个月于2010年12月13日入院。入院查体:意识清,精神好,巩膜无黄染,颈软无抵抗,颈动脉搏动正常,肝颈静脉回流征阴性。右侧颈部可及一约5.0 cm×4.0 cm肿物,表面光滑、边界清、随吞咽上下运动,左侧未触及肿物。颈部无肿大淋巴结,气管居中。颈部彩超检查示右侧甲状腺体积增大, 展开更多
关键词 甲状腺体积 乳腺重复癌 肝颈静脉回流 入院查体 肿大淋巴结 动脉搏动 表面光滑 上下运动
下载PDF
乳腺重复癌五例报告
2
作者 亓建 汤绪珍 《肿瘤防治杂志》 2002年第5期456-456,共1页
关键词 乳腺重复癌 诊断 病例报告 治疗
下载PDF
Long Term Reproducibility Check of a Full Field Digital Mammography System
3
作者 Francesca Pietrobon Salvatore Panarello +2 位作者 Orazio De Toffol Marco Toigo Elena Bellan 《Journal of Physical Science and Application》 2016年第5期42-53,共12页
In this study different types of customized phantoms were used to examine a long term reproducibility check of a full field digital mammography system. These phantoms can be distinguished into three types: a PMMA (p... In this study different types of customized phantoms were used to examine a long term reproducibility check of a full field digital mammography system. These phantoms can be distinguished into three types: a PMMA (polimethylmethacrylate) object for an easy signal-to-noise ratio measurement in a defined region, a phantom with particular details of various dimensions (TORMAS) and a phantom for a contrast-detail analysis (CDMAM). In our center the ARTINIS ANALYZER software has been used since 2011 to weekly perform a CDMAM phantom analysis. This soitware is based on the original CDCOM algorithm suggested by the EUREF, the European Reference Organization for assured quality breast screening and diagnostic services. However the CDMAM phantom is a contrast-detail object designed for image quality type tests and not for long term reproducibility control. Since 2013, as suggested by the guidelines of Veneto region, a TORMAS weekly acquisition and analysis of data has also been performed. The purpose of this study is to discuss the data obtained by using the two different detail phantoms, CDMAM and TORMAS. These results can provide some correlations among the analyzed parameters comparing them with the ones emerging from the PMMA phantom analysis. The study reveals that the basic PMMA phantom is the object that provides the necessary information about the stability of the exposure parameters and the reproducibility of a mammographic equipment in terms of image quality indexes. 展开更多
关键词 Contrast-detail phantoms digital mammography long-term reproducibility.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部