期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Carbon dioxide insufflation during colonoscopy in deeply sedated patients 被引量:4
1
作者 Rajvinder Singh Eu Nice Neo +8 位作者 Nazree Nordeen Ganesananthan Shanmuganathan Angelie Ashby Sharon Drummond Garry Nind Elizabeth Murphy Andrew Luck Graeme Tucker William Tam 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第25期3250-3253,共4页
AIM:To compare the impact of carbon dioxide(CO2) and air insufflation on patient tolerance/safety in deeply sedated patients undergoing colonoscopy.METHODS:Patients referred for colonoscopy were randomized to receive ... AIM:To compare the impact of carbon dioxide(CO2) and air insufflation on patient tolerance/safety in deeply sedated patients undergoing colonoscopy.METHODS:Patients referred for colonoscopy were randomized to receive either CO2 or air insufflation during the procedure.Both the colonoscopist and patient were blinded to the type of gas used.During the procedure,insertion and withdrawal times,caecal intubationrates,total sedation given and capnography readings were recorded.The level of sedation and magnitude of patient discomfort during the procedure was assessed by a nurse using a visual analogue scale(VAS)(0-3).Patients then graded their level of discomfort and abdominal bloating using a similar VAS.Complications during and after the procedure were recorded.RESULTS:A total of 142 patients were randomized with 72 in the air arm and 70 in the CO2 arm.Mean age between the two study groups were similar.Insertion time to the caecum was quicker in the CO2 group at 7.3 min vs 9.9 min with air(P = 0.0083).The average withdrawal times were not significantly different between the two groups.Caecal intubation rates were 94.4% and 100% in the air and CO2 groups respectively(P = 0.012).The level of discomfort assessed by the nurse was 0.69(air) and 0.39(CO2)(P = 0.0155) and by the patient 0.82(air) and 0.46(CO2)(P = 0.0228).The level of abdominal bloating was 0.97(air) and 0.36(CO2)(P = 0.001).Capnography readings trended to be higher in the CO2 group at the commencement,caecal intubation,and conclusion of the procedure,even though this was not significantly different when compared to readings obtained during air insufflation.There were no complications in both arms.CONCLUSION:CO2 insufflation during colonoscopy is more efficacious than air,allowing quicker and better cecal intubation rates.Abdominal discomfort and bloating were significantly less with CO2 insufflation. 展开更多
关键词 COLONOSCOPY Carbon dioxide Air Insuffla-tions Patient tolerance Safety Efficacy
下载PDF
生活慢下来,发展快起来
2
作者 胡佳 鄂慧萱 《中国老区建设》 2020年第4期49-51,共3页
老促会是个什么样的组织?他们始终"围绕中心、服务大局",他们"提笔能写、对筒能讲",他们日常是践行初心的宣传队、调研队,走出去又是善于担当的扶贫队、抗"疫"队。湖北省扶贫基金会理事长刘建新说,自从... 老促会是个什么样的组织?他们始终"围绕中心、服务大局",他们"提笔能写、对筒能讲",他们日常是践行初心的宣传队、调研队,走出去又是善于担当的扶贫队、抗"疫"队。湖北省扶贫基金会理事长刘建新说,自从来了老促会,须臾不敢忘记的责任让他又增加了"转危为机"的种种"特技"。刘建新,是湖北省老促会系统的一个代表,刘建新的故事,是全国老促会系统的一个缩影。 展开更多
关键词 老促会 刘建新 疫情防控 扶贫基金会 二程镇 湖北省
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部