Separate type heat pipe heat exchangers are often used for large-scale heat exchanging. The arrangement of such a heat exchanger conveniently allows heat input to and output from the heat exchanger at remote locations...Separate type heat pipe heat exchangers are often used for large-scale heat exchanging. The arrangement of such a heat exchanger conveniently allows heat input to and output from the heat exchanger at remote locations. The traditional method of designing an ordinary HPHE (heat pipe heat exchanger) is commonly applied in the separate type exchanger design, but the calculations have to be carried out separately, which makes it very complicated. In this work, the ε-NTU (effectiveness-Number of Transfer Units) method was applied for optimization analysis of single- or multi-level separate type heat pipe heat exchangers. An optimizing formula for single-level separate type heat pipe heat exchangers was obtained. The optimizing principles of effec- tiveness-NTU and heat transfer rate by the equal distribution method for multi-level separate type heat pipe heat exchanger are presented. The design of separate type heat pipe heat exchangers by the optimizing method is more convenient and faster than by the traditional method.展开更多
Li Fe PO4/C was prepared via solid state reaction and characterized with X-ray powder diffraction and charge–discharge test. As-prepared Li Fe PO4/C has a triphylite structure and exhibits an excellent rate capabilit...Li Fe PO4/C was prepared via solid state reaction and characterized with X-ray powder diffraction and charge–discharge test. As-prepared Li Fe PO4/C has a triphylite structure and exhibits an excellent rate capability and capacity retention. Electrochemical impedance spectroscopy(EIS) was applied to investigate LixFe PO4/C(0<x<1) electrode on temperature variation. The valid equivalent circuit for EIS fitting was determined which contains an intercalation capacitance for Li+ ion accumulation and consumption in the electrode reaction. The surface layer impedance needs to be included in the equivalent circuit when Li Fe PO4/C is deeply delithiated at a relatively high temperature. EIS examination indicates that a temperature rise leads to a better reversibility, lower charge transfer resistance, higher exchange current density J0 and greater Li+ ion diffusion coefficient for the LixFe PO4/C electrode process. The Li+ ion concentration in LixFe PO4/C is potential to impact the Li+ ion diffusion coefficient, and a decrease in the former results in an increase in the latter.展开更多
A heat transfer model for three-fluid separated heat pipe exchanger was analyzed,and the temperature transfer matrix for general three-fluid separated heat exchanger working in parallel-flow or counter-flow mode was o...A heat transfer model for three-fluid separated heat pipe exchanger was analyzed,and the temperature transfer matrix for general three-fluid separated heat exchanger working in parallel-flow or counter-flow mode was obtained.It was found that the forms of temperature transfer matrix are similar for heat pipe rows with equal or different heat transfer surface area.Furthermore,by using the temperature transfer matrix of the heat pipe exchanger,the relationship between heat transfer effectiveness θ 1,θ 2 and M,NTU,U,Δt i were derived for the exchanger operating in parallel-flow or counter-flow mode,and a simple special example was adopted to demonstrate the correctness of these relationships.展开更多
In this paper, a characterization of all pentavalent arc-transitive graphs is given. It is shown that each pentavalent arc-transitive covering graph F is a regular simple or elementary abelian covering graph. In parti...In this paper, a characterization of all pentavalent arc-transitive graphs is given. It is shown that each pentavalent arc-transitive covering graph F is a regular simple or elementary abelian covering graph. In particular, the elementary abelian covering groups are Z3,Z5or a subgroup of Z2^5.展开更多
Time dependent carbon transfer coefficients are estimated using ecosystem exchange databy minimizing over variable observational intervals,Kalman filter,and variational minimization techniques.Transfer coefficients ar...Time dependent carbon transfer coefficients are estimated using ecosystem exchange databy minimizing over variable observational intervals,Kalman filter,and variational minimization techniques.Transfer coefficients are determined by application of estimation procedures to subintervalsfrom a partition of the observational time period,minimizing the variance of analyzed errors withoutthe imposition of a priori transfer coefficient models in Kalman filters,and minimization with respectto transfer coefficients in variational fit-to-data functionals.Results are compared between methodsand seasonal variability is observed in the transfer coefficients.展开更多
基金the Foundations of the Natural Science ofShaanxi, China (2001Sl04 2004A19)+1 种基金Specialized Scientific Research of Education Department of Shaanxi,China(02JK191)Key Scientific research of Weinan Teachers University, China(08YKF014)
文摘Separate type heat pipe heat exchangers are often used for large-scale heat exchanging. The arrangement of such a heat exchanger conveniently allows heat input to and output from the heat exchanger at remote locations. The traditional method of designing an ordinary HPHE (heat pipe heat exchanger) is commonly applied in the separate type exchanger design, but the calculations have to be carried out separately, which makes it very complicated. In this work, the ε-NTU (effectiveness-Number of Transfer Units) method was applied for optimization analysis of single- or multi-level separate type heat pipe heat exchangers. An optimizing formula for single-level separate type heat pipe heat exchangers was obtained. The optimizing principles of effec- tiveness-NTU and heat transfer rate by the equal distribution method for multi-level separate type heat pipe heat exchanger are presented. The design of separate type heat pipe heat exchangers by the optimizing method is more convenient and faster than by the traditional method.
基金Project(2010ZC051)supported by the Natural Science Foundation of Yunnan Province,ChinaProject(20140439)supported by Analysis and Testing Foundation from Kunming University of Science and Technology,ChinaProject(14118245)supported by Starting Research Fund from Kunming University of Science and Technology,China
文摘Li Fe PO4/C was prepared via solid state reaction and characterized with X-ray powder diffraction and charge–discharge test. As-prepared Li Fe PO4/C has a triphylite structure and exhibits an excellent rate capability and capacity retention. Electrochemical impedance spectroscopy(EIS) was applied to investigate LixFe PO4/C(0<x<1) electrode on temperature variation. The valid equivalent circuit for EIS fitting was determined which contains an intercalation capacitance for Li+ ion accumulation and consumption in the electrode reaction. The surface layer impedance needs to be included in the equivalent circuit when Li Fe PO4/C is deeply delithiated at a relatively high temperature. EIS examination indicates that a temperature rise leads to a better reversibility, lower charge transfer resistance, higher exchange current density J0 and greater Li+ ion diffusion coefficient for the LixFe PO4/C electrode process. The Li+ ion concentration in LixFe PO4/C is potential to impact the Li+ ion diffusion coefficient, and a decrease in the former results in an increase in the latter.
文摘A heat transfer model for three-fluid separated heat pipe exchanger was analyzed,and the temperature transfer matrix for general three-fluid separated heat exchanger working in parallel-flow or counter-flow mode was obtained.It was found that the forms of temperature transfer matrix are similar for heat pipe rows with equal or different heat transfer surface area.Furthermore,by using the temperature transfer matrix of the heat pipe exchanger,the relationship between heat transfer effectiveness θ 1,θ 2 and M,NTU,U,Δt i were derived for the exchanger operating in parallel-flow or counter-flow mode,and a simple special example was adopted to demonstrate the correctness of these relationships.
文摘In this paper, a characterization of all pentavalent arc-transitive graphs is given. It is shown that each pentavalent arc-transitive covering graph F is a regular simple or elementary abelian covering graph. In particular, the elementary abelian covering groups are Z3,Z5or a subgroup of Z2^5.
文摘Time dependent carbon transfer coefficients are estimated using ecosystem exchange databy minimizing over variable observational intervals,Kalman filter,and variational minimization techniques.Transfer coefficients are determined by application of estimation procedures to subintervalsfrom a partition of the observational time period,minimizing the variance of analyzed errors withoutthe imposition of a priori transfer coefficient models in Kalman filters,and minimization with respectto transfer coefficients in variational fit-to-data functionals.Results are compared between methodsand seasonal variability is observed in the transfer coefficients.