For the next generation optical switching networks, the intelligent control plane is a key enabling technique. In this paper, we review our recent research activities related to Generalized Multi-Protocol Label Switch...For the next generation optical switching networks, the intelligent control plane is a key enabling technique. In this paper, we review our recent research activities related to Generalized Multi-Protocol Label Switching (GMPLS) and Open Flow-based control planes for both Wave length Switched Optical Networks (WSON) and Elastic Optical Networks (EON).展开更多
Ethernet Ring Protection (ERP) introduced by ITU-T G.8032 Recommendation is a new type of packet-switched network protection technology, which can provide ring automatic protection switch. However, the Filtering Datab...Ethernet Ring Protection (ERP) introduced by ITU-T G.8032 Recommendation is a new type of packet-switched network protection technology, which can provide ring automatic protection switch. However, the Filtering Database (FDB) flush method adopted in the current ERP standard has the drawback of introducing a large amount of transient traffic overshoot caused by flooded Ethernet frames right after protection switching. In this article, we propose a G.8032 ERP scheme that uses FDB flush based on area to resolve this issue and investigate how the proposed scheme deals with the traffic flooding problem. The theoretical analysis and simulation show that the proposed scheme can effectively improve the performance of the Ethernet ring by decreasing the unnecessary FDB flush in comparison with the existing approaches.展开更多
Conventional optical burst switching(OBS)technique adopts purely statistical multiplex mechanismso that the bursts collide with each other very easily.To address this problem,a novel proactive con-tention avoidance sc...Conventional optical burst switching(OBS)technique adopts purely statistical multiplex mechanismso that the bursts collide with each other very easily.To address this problem,a novel proactive con-tention avoidance scheme is proposed,which assigns dedicated wavelengths to each ingress node,then st-numbering algorithm is used to construct the traffic load balanced spanning trees .In this way,contentioncan be eliminated at ingress nodes,and the amount of bursts that could be accommodated by ingressnodes will be maximized.Further,those unused wavelengths left by traffic load balanced spanning treeare also organized as partial trees to carry bursts,thus the link utilization can be improved effectively.Simulation result shows that our scheme can improve the burst loss performance significantly without thewavelength converters or optical buffers comparing to other popular routing and wavelength assignment(RWA)algorithms.展开更多
A new superstructure model of heat exchanger networks (HEN) with streamsplits based on rangers of streams supply temperatures and heat capacity flow rates is presented.The simultaneous optimal mathematical model of fl...A new superstructure model of heat exchanger networks (HEN) with streamsplits based on rangers of streams supply temperatures and heat capacity flow rates is presented.The simultaneous optimal mathematical model of flexible HEN synthesis is established too. Firstly,the streams with rangers of supply temperatures and/or the streams with the rangers of heat capacityflow rates are pretreated; Secondly, several rules are proposed to establish the superstructuremodel of HEN with splits and the simultaneous optimal mathematical model of flexible HEN; Thirdly,the improving genetic algorithm is applied to solve the mathematical model established at the secondstep effectively, and the original optimal structure of HEN based on the maximum operation limitingcondition can be obtained easily; Finally, the rules of heat exchange unit merged and the heat loadof heat exchanger relaxed are presented, the flexible configuration of HEN satisfied the operationcondition between the upper and down bounds of supply temperature and heat capacity flow rates canbe obtained based on the original optimal structure of HEN by means of these rules. A case studydemonstrates the method presented in this paper is effective展开更多
文摘For the next generation optical switching networks, the intelligent control plane is a key enabling technique. In this paper, we review our recent research activities related to Generalized Multi-Protocol Label Switching (GMPLS) and Open Flow-based control planes for both Wave length Switched Optical Networks (WSON) and Elastic Optical Networks (EON).
基金supported partially by National Science and Technology Major Project of the Ministry of Science and Technology of China under Grant No.2011ZX03005-004-03 a Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions-Information and Communication Engineering,Natural Science Foundation of the Higher Education Institutions of Jiangsu Province,China under Grant No.10KJA510037+1 种基金 Open Research Fund of Key Lab of Broadband Wireless Communication and Sensor Network Technology(Nanjing University of Posts and Telecommunications),Ministry of Education under Grant No.NYKL201108 Natural Science Foundation of Nanjing University of Posts and Telecommunications under Grant No.NY209002
文摘Ethernet Ring Protection (ERP) introduced by ITU-T G.8032 Recommendation is a new type of packet-switched network protection technology, which can provide ring automatic protection switch. However, the Filtering Database (FDB) flush method adopted in the current ERP standard has the drawback of introducing a large amount of transient traffic overshoot caused by flooded Ethernet frames right after protection switching. In this article, we propose a G.8032 ERP scheme that uses FDB flush based on area to resolve this issue and investigate how the proposed scheme deals with the traffic flooding problem. The theoretical analysis and simulation show that the proposed scheme can effectively improve the performance of the Ethernet ring by decreasing the unnecessary FDB flush in comparison with the existing approaches.
基金supported by the National Natural Science Foundation of China(No.60572050)the National High Technology Research and Development Programme of China(No.2008AA01Z211)
文摘Conventional optical burst switching(OBS)technique adopts purely statistical multiplex mechanismso that the bursts collide with each other very easily.To address this problem,a novel proactive con-tention avoidance scheme is proposed,which assigns dedicated wavelengths to each ingress node,then st-numbering algorithm is used to construct the traffic load balanced spanning trees .In this way,contentioncan be eliminated at ingress nodes,and the amount of bursts that could be accommodated by ingressnodes will be maximized.Further,those unused wavelengths left by traffic load balanced spanning treeare also organized as partial trees to carry bursts,thus the link utilization can be improved effectively.Simulation result shows that our scheme can improve the burst loss performance significantly without thewavelength converters or optical buffers comparing to other popular routing and wavelength assignment(RWA)algorithms.
基金Supported by the State Major Basic Research Department Program of China (No. G20000263) and the Deutsche Forschungs- gemeinschaft(DFG)(No. RO294/9).
文摘A new superstructure model of heat exchanger networks (HEN) with streamsplits based on rangers of streams supply temperatures and heat capacity flow rates is presented.The simultaneous optimal mathematical model of flexible HEN synthesis is established too. Firstly,the streams with rangers of supply temperatures and/or the streams with the rangers of heat capacityflow rates are pretreated; Secondly, several rules are proposed to establish the superstructuremodel of HEN with splits and the simultaneous optimal mathematical model of flexible HEN; Thirdly,the improving genetic algorithm is applied to solve the mathematical model established at the secondstep effectively, and the original optimal structure of HEN based on the maximum operation limitingcondition can be obtained easily; Finally, the rules of heat exchange unit merged and the heat loadof heat exchanger relaxed are presented, the flexible configuration of HEN satisfied the operationcondition between the upper and down bounds of supply temperature and heat capacity flow rates canbe obtained based on the original optimal structure of HEN by means of these rules. A case studydemonstrates the method presented in this paper is effective