This paper describes the transmission capability of Tian-Guang AC and DC hybrid system, as well as various operational effects on the transmission capability, such as HVDC modulation, AC voltage level and generating r...This paper describes the transmission capability of Tian-Guang AC and DC hybrid system, as well as various operational effects on the transmission capability, such as HVDC modulation, AC voltage level and generating reserves. The study has shown that when both AC and DC systems operated in parallel, this system has higher transmission capability than operated separately, thus it satisfies stability criterion after the project put into operation.展开更多
The transfer function of the optical splitting system of the acousto-optic tunable filter (AOTF) is deduced to be a reference to optical design. The characteristic matrix ( transfer function) of AOTF is used to de...The transfer function of the optical splitting system of the acousto-optic tunable filter (AOTF) is deduced to be a reference to optical design. The characteristic matrix ( transfer function) of AOTF is used to describe quantitatively the characters of polarization elements in the orthogonal polarizing system. According to the characteristic matrix, the included angle of polarizer's transmission direction and polarization analyzer's transmission direction should be 90°. As a result the signal to noise ratio increased about 20 times though the light intensity was reduced to 54.3%,because both the transmittances of polarizer and polarization analyzer are 0. 74, which is an intrinsic character. The orthogonal polarizing method is an effective method to get rid of the influence of zero order light and improve the spectrum resolution and signal-to-noise ratio.展开更多
In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be r...In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be recharged in high efficiency.With equal heat transfer capabilities of exhaust-air coil and borehole collector,the system provides a maximum overall efficiency.However,due to ground infinite capacity,the optimum brine flow rate is different from conventional two-exchanger system.The recharging system provides two peak overall efficiencies when the capacity ratio Cr=5 for laminar flow and Cr=15 for turbulent flow respectively.The overall efficiency is independent of exhaust-air temperature and undisturbed ground temperature,although the fluid properties depend on temperature.In practical system lower ethyl percentage brine should be chosen if the freezing point meets the system request,which can provide a higher overall efficiency.展开更多
To analyze the influence of _+400 kV Q^nghai-Tibet HVDC transmission system on transmission- line protections in Qjnghai AG power system, a closed-loop simulation system was constructed by combing HyperSim system wit...To analyze the influence of _+400 kV Q^nghai-Tibet HVDC transmission system on transmission- line protections in Qjnghai AG power system, a closed-loop simulation system was constructed by combing HyperSim system with HVDG control protection devices. Various faults on double-circuit 750 kV and multi- circuit 330 kV AC transmission lines in Qjnghai power system were simulated. The impedance characteristics and harmonic components at Qjnghai side of Qjng-Tibet DG transmission line were analyzed. The harmonic proportion in voltages and currents were studied for faults that took place at different locations near the DG system. The inflence of Qing-Tibet DG system on the directional components of protections, differential protections and distance protections of AC transmission lines was discussed and drew the conclusions that the DC sytem had little influence on differential protections, while had great inflence on directional components and distance protection. The conclusions can provide reference for studying the interaction between AC and DG systems.展开更多
文摘This paper describes the transmission capability of Tian-Guang AC and DC hybrid system, as well as various operational effects on the transmission capability, such as HVDC modulation, AC voltage level and generating reserves. The study has shown that when both AC and DC systems operated in parallel, this system has higher transmission capability than operated separately, thus it satisfies stability criterion after the project put into operation.
文摘The transfer function of the optical splitting system of the acousto-optic tunable filter (AOTF) is deduced to be a reference to optical design. The characteristic matrix ( transfer function) of AOTF is used to describe quantitatively the characters of polarization elements in the orthogonal polarizing system. According to the characteristic matrix, the included angle of polarizer's transmission direction and polarization analyzer's transmission direction should be 90°. As a result the signal to noise ratio increased about 20 times though the light intensity was reduced to 54.3%,because both the transmittances of polarizer and polarization analyzer are 0. 74, which is an intrinsic character. The orthogonal polarizing method is an effective method to get rid of the influence of zero order light and improve the spectrum resolution and signal-to-noise ratio.
文摘In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be recharged in high efficiency.With equal heat transfer capabilities of exhaust-air coil and borehole collector,the system provides a maximum overall efficiency.However,due to ground infinite capacity,the optimum brine flow rate is different from conventional two-exchanger system.The recharging system provides two peak overall efficiencies when the capacity ratio Cr=5 for laminar flow and Cr=15 for turbulent flow respectively.The overall efficiency is independent of exhaust-air temperature and undisturbed ground temperature,although the fluid properties depend on temperature.In practical system lower ethyl percentage brine should be chosen if the freezing point meets the system request,which can provide a higher overall efficiency.
文摘To analyze the influence of _+400 kV Q^nghai-Tibet HVDC transmission system on transmission- line protections in Qjnghai AG power system, a closed-loop simulation system was constructed by combing HyperSim system with HVDG control protection devices. Various faults on double-circuit 750 kV and multi- circuit 330 kV AC transmission lines in Qjnghai power system were simulated. The impedance characteristics and harmonic components at Qjnghai side of Qjng-Tibet DG transmission line were analyzed. The harmonic proportion in voltages and currents were studied for faults that took place at different locations near the DG system. The inflence of Qing-Tibet DG system on the directional components of protections, differential protections and distance protections of AC transmission lines was discussed and drew the conclusions that the DC sytem had little influence on differential protections, while had great inflence on directional components and distance protection. The conclusions can provide reference for studying the interaction between AC and DG systems.