The vibration behavior of the ground and houses caused by monorail traffic is discussed in this paper. The environmental ground vibration problem discussed herein occurs in a residential area near a monorail used for ...The vibration behavior of the ground and houses caused by monorail traffic is discussed in this paper. The environmental ground vibration problem discussed herein occurs in a residential area near a monorail used for public transportation, Vibrations were measured on the ground at the side of monorail piers lacing the residential area and within the affected houses. Results indicate that the vibration level in the house was 60 dB or more, a level high enough to warrant complaints, Peculiar geological and geographical features are thought to contribute to the amplification of low frequency (-10 Hz) ground vibrations to irritable levels in these homes even though a distance of≥30 m separates the residential area and the monorail.展开更多
The rapid development of high-speed transportation infrastructure such as highway and high-speed railway has resulted in the advancement of soft soil improvement techniques. Vacuum preloading combined with vertical dr...The rapid development of high-speed transportation infrastructure such as highway and high-speed railway has resulted in the advancement of soft soil improvement techniques. Vacuum preloading combined with vertical drains has been proved to be an effective method in the treatment of soft foundation. A three-dimensional numerical analysis of the coupled methods was presented, in which the smear zone and the well resistance were taken into account. The variations of the basic soil parameters including the permeability coefficient and the coefficient of volume compressibility were considered in the numerical model. The result of the numerical model was then compared to the measured value. The results indicate that the decrease of coefficient of volume compressibility accelerates the consolidation of the soil while the influence of hydraulic conductivity is insignificant. A cube drain presents the closest result to the real situation compared to the other equivalent methods of prefabricated vertical drain (PVD). The case study indicates that the numerical model with variation of soil parameters is closer to the measured value than the numerical model without variation of soil parameters.展开更多
文摘The vibration behavior of the ground and houses caused by monorail traffic is discussed in this paper. The environmental ground vibration problem discussed herein occurs in a residential area near a monorail used for public transportation, Vibrations were measured on the ground at the side of monorail piers lacing the residential area and within the affected houses. Results indicate that the vibration level in the house was 60 dB or more, a level high enough to warrant complaints, Peculiar geological and geographical features are thought to contribute to the amplification of low frequency (-10 Hz) ground vibrations to irritable levels in these homes even though a distance of≥30 m separates the residential area and the monorail.
基金Project(2010THZ021)supported by Tsinghua University,ChinaProject(50978139)supported by the National Natural Science Foundation of ChinaProject(2012CB719804)supported by the National Basic Research Program of China
文摘The rapid development of high-speed transportation infrastructure such as highway and high-speed railway has resulted in the advancement of soft soil improvement techniques. Vacuum preloading combined with vertical drains has been proved to be an effective method in the treatment of soft foundation. A three-dimensional numerical analysis of the coupled methods was presented, in which the smear zone and the well resistance were taken into account. The variations of the basic soil parameters including the permeability coefficient and the coefficient of volume compressibility were considered in the numerical model. The result of the numerical model was then compared to the measured value. The results indicate that the decrease of coefficient of volume compressibility accelerates the consolidation of the soil while the influence of hydraulic conductivity is insignificant. A cube drain presents the closest result to the real situation compared to the other equivalent methods of prefabricated vertical drain (PVD). The case study indicates that the numerical model with variation of soil parameters is closer to the measured value than the numerical model without variation of soil parameters.