The harsh space radiation environment compromises the reliability of an on-board switching fabric by leading to cross-point and switching element(SE)faults.Different from traditional faulttolerant switching fabrics on...The harsh space radiation environment compromises the reliability of an on-board switching fabric by leading to cross-point and switching element(SE)faults.Different from traditional faulttolerant switching fabrics only taking crosspoint faults into account,a novel Input and Output Parallel Clos network,referred to as the(p_1,p_2)-IOPClos,is proposed to tolerate both cross-point and SE faults.In the(p_1,p_2)-IOPClos,there are p_1 and p_2 expanded parallel switching planes in the input and output stages,respectively.The multiple input/output switching planes are interconnected through the middle stage to provide multiple paths in each stage by which the network throughput can be increased remarkably.Furthermore,the network reliability of the(p_1,p_2)-IOPClos under the above both kinds of faults is analyzed.The corresponding implementation cost is also presented along with the network size.Both theoretical analysis and numerical results indicate that the(p_1,p_2)-IOPClos outperforms traditional Clos-type networks at reliability,while has less implementation cost than the multi-plane Clos network.展开更多
基金supported by the National Natural Science Foundation of China(91338108,91438206)
文摘The harsh space radiation environment compromises the reliability of an on-board switching fabric by leading to cross-point and switching element(SE)faults.Different from traditional faulttolerant switching fabrics only taking crosspoint faults into account,a novel Input and Output Parallel Clos network,referred to as the(p_1,p_2)-IOPClos,is proposed to tolerate both cross-point and SE faults.In the(p_1,p_2)-IOPClos,there are p_1 and p_2 expanded parallel switching planes in the input and output stages,respectively.The multiple input/output switching planes are interconnected through the middle stage to provide multiple paths in each stage by which the network throughput can be increased remarkably.Furthermore,the network reliability of the(p_1,p_2)-IOPClos under the above both kinds of faults is analyzed.The corresponding implementation cost is also presented along with the network size.Both theoretical analysis and numerical results indicate that the(p_1,p_2)-IOPClos outperforms traditional Clos-type networks at reliability,while has less implementation cost than the multi-plane Clos network.