Photoneutrons, emitted by means of photonuclear interactions when gas bremsstrahlung interacts with beamline components, can be another potential radiation source needed to be considered for shielding design and dose ...Photoneutrons, emitted by means of photonuclear interactions when gas bremsstrahlung interacts with beamline components, can be another potential radiation source needed to be considered for shielding design and dose assessment of beamline. In this paper, simulations and measurements of photoneutrons dose rate at beamline BL09 U are carried out when Shanghai Synchrotron Radiation Facility(SSRF) running at Top-up mode(3.5 GeV, 235 mA). A geometry model is constructed for the beamline BL09 U with considerations of the scattering process of the major optical components. The model is compiled into Monte Carlo simulation code FLUKA to calculate photoneutron dose distribution. Measurements of the photoneutrons dose rate were performed by using Environmental Neutron Monitor(ENM). Observation points were arranged uniformly along the inside and outside of the optical enclosure(OE) of BL09 U. The calculation results agree with experiments within the measurements uncertainties. It is verified that photoneutrons dose simulation is reliable. The simulation and measurement methods can be applied to evaluate the neutron dose level of other beamline stations, and provide references for the shielding design of the beamlines at SSRF in the near future.展开更多
Neutron energy, fluence rate, angular distributions and dose equivalent rate distributions around the thick Be, Cu, An targets bombarded by 50 MeV/u 18O-ion were measured using a threshold detector activation method. ...Neutron energy, fluence rate, angular distributions and dose equivalent rate distributions around the thick Be, Cu, An targets bombarded by 50 MeV/u 18O-ion were measured using a threshold detector activation method. At the same time,the neutron yields of 18O-ion and the neutron emission rates in the forward direction were obtained approximately.展开更多
文摘Photoneutrons, emitted by means of photonuclear interactions when gas bremsstrahlung interacts with beamline components, can be another potential radiation source needed to be considered for shielding design and dose assessment of beamline. In this paper, simulations and measurements of photoneutrons dose rate at beamline BL09 U are carried out when Shanghai Synchrotron Radiation Facility(SSRF) running at Top-up mode(3.5 GeV, 235 mA). A geometry model is constructed for the beamline BL09 U with considerations of the scattering process of the major optical components. The model is compiled into Monte Carlo simulation code FLUKA to calculate photoneutron dose distribution. Measurements of the photoneutrons dose rate were performed by using Environmental Neutron Monitor(ENM). Observation points were arranged uniformly along the inside and outside of the optical enclosure(OE) of BL09 U. The calculation results agree with experiments within the measurements uncertainties. It is verified that photoneutrons dose simulation is reliable. The simulation and measurement methods can be applied to evaluate the neutron dose level of other beamline stations, and provide references for the shielding design of the beamlines at SSRF in the near future.
文摘Neutron energy, fluence rate, angular distributions and dose equivalent rate distributions around the thick Be, Cu, An targets bombarded by 50 MeV/u 18O-ion were measured using a threshold detector activation method. At the same time,the neutron yields of 18O-ion and the neutron emission rates in the forward direction were obtained approximately.