A new HPLC MS method to determine loratadine in human plasma was established. The method involved extracting drug with organic solvent under basic conditions. The samples were seperated by ODS column and determined ...A new HPLC MS method to determine loratadine in human plasma was established. The method involved extracting drug with organic solvent under basic conditions. The samples were seperated by ODS column and determined by mass detector. The calibration curve of loratadine was linear within the range of 0.4~100 ng·mL -1 with r=0.9995 . The recovery of this method was within 95%~104%, within day and between day RSD were less than 12%. To study the pharmacokinetics and relative bioavailability of loratadine tablets, two formulations of loratadine tablets were given to 18 healthy male volunteers according to a randomized 2 way cross over design. The C max , AUC 0 t and T max values of the two formulations were 51.89±20.18 ng·mL -1 and 52.48±22.35 ng·mL -1 ; 140.75±88.42 ng·h·mL -1 and 147.24±92.33 ng·h·mL -1 ; 0.81±0.35 h and 0.81±0.27 h respectively. Results from statistic analysis showed that there were no significant difference between the C max , AUC 0-t and T max values of the two formulations. The relative bioavailability of tablets I with respect to tablets II was 97%±13% from the AUC 0 t measurement. Bioequivalance was observed between the two tablets.展开更多
Aim To establish a sensitive and specific liquid chromatography-mass spectrometry (HPLC-MS) method for measuring lovastatin level in human plasma and the relative bioavailability. Methods Lovastatin in the plasma was ...Aim To establish a sensitive and specific liquid chromatography-mass spectrometry (HPLC-MS) method for measuring lovastatin level in human plasma and the relative bioavailability. Methods Lovastatin in the plasma was extracted with acetoacetate. Simvastatin was added as internal standard (IS). Samples were separated on a C_ 18 column with a mobile phase consisting of methanol and 50 mmol·L~ -1 sodium acetate (88 ∶ 12). The flow rate was 1 mL·min~ -1 . Sample was detected using an electrospray ionization (ES...展开更多
文摘A new HPLC MS method to determine loratadine in human plasma was established. The method involved extracting drug with organic solvent under basic conditions. The samples were seperated by ODS column and determined by mass detector. The calibration curve of loratadine was linear within the range of 0.4~100 ng·mL -1 with r=0.9995 . The recovery of this method was within 95%~104%, within day and between day RSD were less than 12%. To study the pharmacokinetics and relative bioavailability of loratadine tablets, two formulations of loratadine tablets were given to 18 healthy male volunteers according to a randomized 2 way cross over design. The C max , AUC 0 t and T max values of the two formulations were 51.89±20.18 ng·mL -1 and 52.48±22.35 ng·mL -1 ; 140.75±88.42 ng·h·mL -1 and 147.24±92.33 ng·h·mL -1 ; 0.81±0.35 h and 0.81±0.27 h respectively. Results from statistic analysis showed that there were no significant difference between the C max , AUC 0-t and T max values of the two formulations. The relative bioavailability of tablets I with respect to tablets II was 97%±13% from the AUC 0 t measurement. Bioequivalance was observed between the two tablets.
文摘Aim To establish a sensitive and specific liquid chromatography-mass spectrometry (HPLC-MS) method for measuring lovastatin level in human plasma and the relative bioavailability. Methods Lovastatin in the plasma was extracted with acetoacetate. Simvastatin was added as internal standard (IS). Samples were separated on a C_ 18 column with a mobile phase consisting of methanol and 50 mmol·L~ -1 sodium acetate (88 ∶ 12). The flow rate was 1 mL·min~ -1 . Sample was detected using an electrospray ionization (ES...