Based on the transmission theory, the mechanism of the generation of the motor terminal over voltage caused by the long line transmission of PWM pulses in the PWM variable frequency driving system is studied. This p...Based on the transmission theory, the mechanism of the generation of the motor terminal over voltage caused by the long line transmission of PWM pulses in the PWM variable frequency driving system is studied. This paper focuses on the effects of the variant length and characteristic impedance of cables on the over voltage by large numbers of experiment results. In terms of the impedance matching method, a network fixed at motor terminal is designed to reduce the over voltage. The utility of this network is testified by the experiments.展开更多
The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV)...The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV) transmission lines in China and UHV transmission lines in Russia and Japan, the methods to suppress the internal overvoltage in UHV transmission lines by protection and control strategies are discussed. Through the cooperation among the recloser, shunt reactor, tripping and closing resistance, and metal oxide varistor(MOV), the overvoltage can be restrained within an acceptable level.展开更多
Coal mining monitoring system has been enforcing tests for the immunity of Electromagnetic Compatibility(EMC) since 2006.However,not all monitoring substations can pass the Electrical Fast Transient/Burst(EFT/B) immun...Coal mining monitoring system has been enforcing tests for the immunity of Electromagnetic Compatibility(EMC) since 2006.However,not all monitoring substations can pass the Electrical Fast Transient/Burst(EFT/B) immunity test and the explosion-proof test simultaneously.In order to enhance EMC,the EFT/B interfere transmission model was presented at the substation power port,after the EFT/B test method was used to analyze the monitoring substation power ports.Hence,a low-pass filter was designed by using the simulation software PIPICE and an anti-jamming method was proposed by way of a parallel connection of the discharge interfere circuit and the low-pass filter.The improved complex EMI filter was made up of an interference discharge device and a filter.The dynamic equivalent circuit was proposed for the EFT/B immunity test.As a result,the monitoring substation has passed the EFT/B immunity and explosion-proof tests with the complex filter.It is concluded that the complex EMI filter has significantly enhanced the immunity of the coal mining monitoring system.展开更多
In this paper,we propose a securityoriented transmission scheme with the help of multiple relays in Cognitive Radio(CR).To maximise the Secrecy Capacity(SC)of the source-destination link in CR,both beamforming and coo...In this paper,we propose a securityoriented transmission scheme with the help of multiple relays in Cognitive Radio(CR).To maximise the Secrecy Capacity(SC)of the source-destination link in CR,both beamforming and cooperative jamming technologies are used to improve the performance of the Secondary User(SU)and protect the Primary User(PU).The effectiveness of the proposed scheme is demonstrated using extensive simulation.Both theoretical analyses and simulation results reveal that the proposed scheme contributes to the secure transmission of the SU with acceptable attenuation of the Signal-to-Noise Ratio(SNR)at the PU receiver,and the upper bound of the SC at the SU receiver is able to exploit the power allocation strategy.展开更多
文摘Based on the transmission theory, the mechanism of the generation of the motor terminal over voltage caused by the long line transmission of PWM pulses in the PWM variable frequency driving system is studied. This paper focuses on the effects of the variant length and characteristic impedance of cables on the over voltage by large numbers of experiment results. In terms of the impedance matching method, a network fixed at motor terminal is designed to reduce the over voltage. The utility of this network is testified by the experiments.
基金ABB (China) Research Ltd. and National Natural Science Foundation of China(No.50477037)
文摘The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV) transmission lines in China and UHV transmission lines in Russia and Japan, the methods to suppress the internal overvoltage in UHV transmission lines by protection and control strategies are discussed. Through the cooperation among the recloser, shunt reactor, tripping and closing resistance, and metal oxide varistor(MOV), the overvoltage can be restrained within an acceptable level.
基金supported by the National Natural Science Foundation of China (No.50674093)the Pingdingshan Coal Co.Ltd. The EMI distribution measurements were obtained from several coal mines of the Pingdingshan Coal Co.
文摘Coal mining monitoring system has been enforcing tests for the immunity of Electromagnetic Compatibility(EMC) since 2006.However,not all monitoring substations can pass the Electrical Fast Transient/Burst(EFT/B) immunity test and the explosion-proof test simultaneously.In order to enhance EMC,the EFT/B interfere transmission model was presented at the substation power port,after the EFT/B test method was used to analyze the monitoring substation power ports.Hence,a low-pass filter was designed by using the simulation software PIPICE and an anti-jamming method was proposed by way of a parallel connection of the discharge interfere circuit and the low-pass filter.The improved complex EMI filter was made up of an interference discharge device and a filter.The dynamic equivalent circuit was proposed for the EFT/B immunity test.As a result,the monitoring substation has passed the EFT/B immunity and explosion-proof tests with the complex filter.It is concluded that the complex EMI filter has significantly enhanced the immunity of the coal mining monitoring system.
基金supported by the National Natural Science Foundation of China under Grants No. 61201150, No. 61171097the Fundamental Research Funds for the Central Universities of BUPT under Grant No. 2013RC0202the State Major Science and Technology Special Projects under Grant No. 2012ZX03004001
文摘In this paper,we propose a securityoriented transmission scheme with the help of multiple relays in Cognitive Radio(CR).To maximise the Secrecy Capacity(SC)of the source-destination link in CR,both beamforming and cooperative jamming technologies are used to improve the performance of the Secondary User(SU)and protect the Primary User(PU).The effectiveness of the proposed scheme is demonstrated using extensive simulation.Both theoretical analyses and simulation results reveal that the proposed scheme contributes to the secure transmission of the SU with acceptable attenuation of the Signal-to-Noise Ratio(SNR)at the PU receiver,and the upper bound of the SC at the SU receiver is able to exploit the power allocation strategy.