In this paper, the stability constants of the o Phdn Co complexes and oxygenated complexes were determined by pH potentiometry for the first time. The determined method was verified with the known o Phdn Cu system by ...In this paper, the stability constants of the o Phdn Co complexes and oxygenated complexes were determined by pH potentiometry for the first time. The determined method was verified with the known o Phdn Cu system by comprising the stability constants obtained from experiment results with those in literatures. The calculated results of oxygenated complexes were confirmed by spectrophotometry. All the results are agreed very well, which show the correctness of the determination.展开更多
The cadmium(Ⅱ)-glycine system was studied by the two experimental techniques, ion sensitive electrode (ISE) and differential pulse polarography (DPP), and the experimental data obtained were used by a unified m...The cadmium(Ⅱ)-glycine system was studied by the two experimental techniques, ion sensitive electrode (ISE) and differential pulse polarography (DPP), and the experimental data obtained were used by a unified mathematical treatment to calculate the complex stability constants. The combination of the two techniques is of many advantages as ISE can be performed at low [LT]:[MT] ratios and significantly higher [MT], whereas DPP could be used well at large [LT]:[MT] ratios and much smaller [MT]. This makes it possible to study a metal-ligand system in a relatively broader range of experimental conditions that, in turn, provides more information about the metakligand system of interest. Applying the unified mathematical treatment to the cadmium-glycine system, two new complexes MHL and ML2(OH) as well as three complexes ML, ML2 and ML3, reported in literatures, could be modeled and all their stability constants have been refined.展开更多
This paper makes use of the method of testing and measuring the human body tibia by using2-D moire interferometry of sticking film. hased on the J'--y direction moire patterns recorded synchronously by 2-D optical...This paper makes use of the method of testing and measuring the human body tibia by using2-D moire interferometry of sticking film. hased on the J'--y direction moire patterns recorded synchronously by 2-D optical path,the elastic constant,strain and displacement of the tibia are measured.Compared with the electric measuring method the error is samll and the sensitivity is high.展开更多
文摘In this paper, the stability constants of the o Phdn Co complexes and oxygenated complexes were determined by pH potentiometry for the first time. The determined method was verified with the known o Phdn Cu system by comprising the stability constants obtained from experiment results with those in literatures. The calculated results of oxygenated complexes were confirmed by spectrophotometry. All the results are agreed very well, which show the correctness of the determination.
文摘The cadmium(Ⅱ)-glycine system was studied by the two experimental techniques, ion sensitive electrode (ISE) and differential pulse polarography (DPP), and the experimental data obtained were used by a unified mathematical treatment to calculate the complex stability constants. The combination of the two techniques is of many advantages as ISE can be performed at low [LT]:[MT] ratios and significantly higher [MT], whereas DPP could be used well at large [LT]:[MT] ratios and much smaller [MT]. This makes it possible to study a metal-ligand system in a relatively broader range of experimental conditions that, in turn, provides more information about the metakligand system of interest. Applying the unified mathematical treatment to the cadmium-glycine system, two new complexes MHL and ML2(OH) as well as three complexes ML, ML2 and ML3, reported in literatures, could be modeled and all their stability constants have been refined.
文摘This paper makes use of the method of testing and measuring the human body tibia by using2-D moire interferometry of sticking film. hased on the J'--y direction moire patterns recorded synchronously by 2-D optical path,the elastic constant,strain and displacement of the tibia are measured.Compared with the electric measuring method the error is samll and the sensitivity is high.