The latitude-altitude distributions of radiative fluxes and heating rates are investigated by utilizing CloudSat satellite data over China during summer. The Tibetan Plateau causes the downward shortwave fluxes of the...The latitude-altitude distributions of radiative fluxes and heating rates are investigated by utilizing CloudSat satellite data over China during summer. The Tibetan Plateau causes the downward shortwave fluxes of the lower atmosphere over central China to be smaller than the fluxes over southern and northern China by generating more clouds. The existence of a larger quantity of clouds over central China reflects a greater amount of solar radiation back into space. The vertical gradients of upward shortwave radiative fluxes in the atmosphere below 8 km are greater than those above 8 km. The latitudinal-altitude distributions of downward longwave radiative fluxes show a slantwise decreasing trend from low latitudes to high latitudes that gradually weaken in the downward direction. The upward longwave radiative fluxes also weaken in the upward direction but with larger gradients. The maximum heating rates by solar radiation and cooling rates by longwave infrared radiation are located over 28 40°N at 7 8 km mean sea level (MSL), and they are larger than the rates in the northern and southern regions. The heating and cooling rates match well both vertically and geographically.展开更多
Cavitation is one of the major problems in the development of rocket engines. There have been few experimental studies to visualize cryogenic foil cavitation. Therefore a new cryogenic cavitation tunnel of blowdown ty...Cavitation is one of the major problems in the development of rocket engines. There have been few experimental studies to visualize cryogenic foil cavitation. Therefore a new cryogenic cavitation tunnel of blowdown type was built. The foil shape is “piano-convex”. This profile was chosen because of simplicity, but also of being similar to the one for a rocket inducer impeller. Working fluids were water at room temperature, hot water and liquid nitrogen. In case of Angle of Attack (AOA)=8°, periodical cavity departure was observed in the experiments of both water at 90℃ and nitrogen at -190℃ under the same velocity 10 m/sec and the same cavitation number 0.7. The frequencies were observed to be 110 and 90 Hz, respectively, and almost coincided with those of vortex shedding from the foil. Temperature depression due to the thermodynamic effect was confirmed in both experiment and simulation especially in the cryogenic cavitation.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.40875084and40705012)the National Key Technologies R&D Program of China(Grant No.2008BAC40B00)
文摘The latitude-altitude distributions of radiative fluxes and heating rates are investigated by utilizing CloudSat satellite data over China during summer. The Tibetan Plateau causes the downward shortwave fluxes of the lower atmosphere over central China to be smaller than the fluxes over southern and northern China by generating more clouds. The existence of a larger quantity of clouds over central China reflects a greater amount of solar radiation back into space. The vertical gradients of upward shortwave radiative fluxes in the atmosphere below 8 km are greater than those above 8 km. The latitudinal-altitude distributions of downward longwave radiative fluxes show a slantwise decreasing trend from low latitudes to high latitudes that gradually weaken in the downward direction. The upward longwave radiative fluxes also weaken in the upward direction but with larger gradients. The maximum heating rates by solar radiation and cooling rates by longwave infrared radiation are located over 28 40°N at 7 8 km mean sea level (MSL), and they are larger than the rates in the northern and southern regions. The heating and cooling rates match well both vertically and geographically.
文摘Cavitation is one of the major problems in the development of rocket engines. There have been few experimental studies to visualize cryogenic foil cavitation. Therefore a new cryogenic cavitation tunnel of blowdown type was built. The foil shape is “piano-convex”. This profile was chosen because of simplicity, but also of being similar to the one for a rocket inducer impeller. Working fluids were water at room temperature, hot water and liquid nitrogen. In case of Angle of Attack (AOA)=8°, periodical cavity departure was observed in the experiments of both water at 90℃ and nitrogen at -190℃ under the same velocity 10 m/sec and the same cavitation number 0.7. The frequencies were observed to be 110 and 90 Hz, respectively, and almost coincided with those of vortex shedding from the foil. Temperature depression due to the thermodynamic effect was confirmed in both experiment and simulation especially in the cryogenic cavitation.