期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
低电位疗法治疗失眠及头痛患者的临床效果分析
1
作者 赵祖谦 李彦杰 《中外医药研究》 2023年第1期48-50,共3页
目的:分析低电位治疗仪对失眠及头痛患者的治疗价值。方法:选取2019年6月—2021年6月新乡市中心医院收治的失眠患者74例及头痛患者52例为研究对象。患者均采取低电位治疗仪治疗,观察患者治疗情况、不良反应及安全性评价。结果:治疗后,... 目的:分析低电位治疗仪对失眠及头痛患者的治疗价值。方法:选取2019年6月—2021年6月新乡市中心医院收治的失眠患者74例及头痛患者52例为研究对象。患者均采取低电位治疗仪治疗,观察患者治疗情况、不良反应及安全性评价。结果:治疗后,失眠患者匹兹堡睡眠质量指数评分低于治疗前,差异有统计学意义(P=0.004);治疗后,头痛患者疼痛视觉模拟评分法评分低于治疗前,差异有统计学意义(P=0.007);失眠患者治疗总有效率为79.73%,头痛患者治疗总有效率为78.85%;受试者均未出现不良反应,接触部位皮肤外观无异常改变、无触电等不良反应,治疗后检测血常规、尿常规、心电图特征,未出现有临床意义的改变。结论:低电位治疗仪在失眠及头痛患者治疗中效果显著,可改善失眠患者睡眠状态,降低头痛患者疼痛程度,无不良反应发生。 展开更多
关键词 低电位治疗 失眠 头痛
下载PDF
Experience of valve replacement under mild hypothermia on pump-beating heart: an analysis of 800 cases
2
作者 陈柏成 肖颖彬 +4 位作者 陈林 钟前进 王学 周骐 易广兵 《Journal of Medical Colleges of PLA(China)》 CAS 2004年第4期247-252,共6页
Objective: To assess the outcome of valve replacement under mild hypothermia on pump-beating heart and to discuss the risk factors of cardiac valve surgery. Methods: In the period from November 1997 to May 2003, a tot... Objective: To assess the outcome of valve replacement under mild hypothermia on pump-beating heart and to discuss the risk factors of cardiac valve surgery. Methods: In the period from November 1997 to May 2003, a total of 800 cases of valve replacement were carried out in our institute. The clinical data were reviewed and the technique of mild hypothermia and pump-beating heart to replace cardiac valve was described in detail. Results: 800 patients, 308 male and 492 female, with age range from 8 to 66 years, weighing 19 to 88 kg, underwent operation. The average cardiopulmonary bypass time was (109.38± 40.64) min, the average clamping time of the vena cava was (77.87±27.99) min and the average mechanical ventilation time was (17.78±12.21) h. There were 17 patients died in the early postoperative stage with an early mortality rate of 2.13%. The causes of death were failure in the weaning of extracorporeal circulation in 2 cases, severe low output syndrome in 3 cases, ventricular fibrillation in 3 cases, obstruction of coronary ostium of mechanical prosthetic valve in 1 case, hepatic failure in 2 cases, pulmonary failure in 1 case, multiorgan failure in 4 cases, and prosthetic valve dysfunction in 1 case. Severe postopertive complications occurred in 51 cases (6.375%), which included reexploration because of excessive bleeding in 16 cases (2.0%), lavage of poststernal infection in 2 cases (0.25%), postoperative strike in 7 cases (0.875%), pulmonary failure in 5 cases (0.625%), hepatic failure in 4 cases (0.5%), multiorgan failure in 11 cases (1.375%), ventricular arrhythmia in 5 cases (0.625%) and peripheral circulation failure in 1 case (0.125%). Conclusion: Mild hypothermia and pump-beating heart result in satisfying clinical outcome in patients undergoing valve replacement. The integrated sequenced deairing procedure ensures the avoidance of air embolism during operation. Pump-beating heart technique offers a safe and practical option especially in patients with severe critical valvular disorder. 展开更多
关键词 valve replacement integrated sequenced deairing procedure pump-beating heart postoperative complication
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部