期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
双DC-DC调压器芯片MC33680的原理及应用
1
作者 许国君 张德营 +1 位作者 曾洁 吴作好 《电子元器件应用》 2009年第3期4-6,9,共4页
介绍了美国MOTOROLA公司生产的一种用于嵌入式手持电子产品的双DC-DC调节器MC33680的主要特性、引脚功能和工作原理,给出了MC33680双DC-DC调压芯片中各功能的应用与设计方法。
关键词 双DC—DC 调压器 传导模式 低电检测 MC33680
下载PDF
Low leakage 3×VDD-tolerant ESD detection circuit without deep N-well in a standard 90-nm low-voltage CMOS process 被引量:3
2
作者 YANG ZhaoNian LIU HongXia WANG ShuLong 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第8期2046-2051,共6页
A new low leakage 3×VDD-tolerant electrostatic discharge(ESD)detection circuit using only low-voltage device without deep N-well is proposed in a standard 90-nm 1.2-V CMOS process.Stacked-transistors technique is... A new low leakage 3×VDD-tolerant electrostatic discharge(ESD)detection circuit using only low-voltage device without deep N-well is proposed in a standard 90-nm 1.2-V CMOS process.Stacked-transistors technique is adopted to sustain high-voltage stress and reduce leakage current.No NMOSFET operates in high voltage range and it is unnecessary to use any deep N-well.The proposed detection circuit can generate a 38 mA current to turn on the substrate triggered silicon-controlled rectifier(STSCR)under the ESD stress.Under normal operating conditions,all the devices are free from over-stress voltage threat.The leakage current is 88 nA under 3×VDD bias at 25°C.The simulation result shows the circuit can be successfully used for 3×VDD-tolerant I/O buffer. 展开更多
关键词 detection circuit electrostatic discharge(ESD) leakage current over-stress voltage stacked-transistors
原文传递
Integration of microfluidic injection analysis with carbon nanomaterials/gold nanowire arrays-based biosensors for glucose detection 被引量:1
3
作者 Yongqiang Qin Jiewu Cui +6 位作者 Yong Zhang Yan Wang Xinyi Zhang Hongmei Zheng Xia Shu Bowen Fu Yucheng Wu 《Science Bulletin》 SCIE EI CAS CSCD 2016年第6期473-480,共8页
Carbon nanotubes(CNTs) and reduced graphene oxide(r GO) nanosheets were utilized to construct glucose biosensors in combination with gold nanowire arrays(Au NWAs), and microfluidic injection analysis driven by gravity... Carbon nanotubes(CNTs) and reduced graphene oxide(r GO) nanosheets were utilized to construct glucose biosensors in combination with gold nanowire arrays(Au NWAs), and microfluidic injection analysis driven by gravity force was used to investigate the performances of as-prepared glucose biosensors. The results demonstrated glucose biosensors based on carbon nanomaterials/Au NWAs presented excellent performance at low working potential of-0.2 V versus Ag/Ag Cl(3 mol/L KCl), such as high sensitivity, good anti-interference ability and high throughput(45 h^(-1)). The glucose biosensor based on glucose oxidase(GOx)–CNT–Au NWAs showed a wide linear range from 100 to 3,000 lmol/L with a sensitivity of 4.12 l A/cm^2 mmol/L. Furthermore, the linear range and sensitivity of GOx–r GO–Au NWAs-based glucose biosensor were 50–4,000 lmol/L and 8.59 l A/(cm^2 mmol/L), respectively, which were better than those of glucose biosensor based on GOx–CNT–Au NWAs,suggesting r GO nanosheets in combination with Au NWAs being a good platform for the construction of glucose biosensors. 展开更多
关键词 Carbon nanotube Reduced graphene oxide Gold nanowire array Microfluidics injection analysis GLUCOSE
原文传递