Based on the data of China Statistical Yearbooks, the current situation and development trend of the energy consumption of residential hot-water was discussed in this paper. Two hundred and sixty eight apartments were...Based on the data of China Statistical Yearbooks, the current situation and development trend of the energy consumption of residential hot-water was discussed in this paper. Two hundred and sixty eight apartments were surveyed on the installation and operation situations of residential water heaters in five cities. Based on survey data, the proportion of pipeline heat loss was calculated in the energy consumption of a shower/bath. The influence factors of heat loss in residential hot-water pipeline network were discussed, and the measures were suggested for reducing the transport heat loss. The statistics and analysis conclusion have directive significance to reducing the transport heat loss.展开更多
Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Bas...Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Based on the field study result, by using the simulation sol, ware, THERB, the effectiveness of the crawlspace warm air heating system has been examined. The effect of the factors, such as the wind amount circulating between crawlspace and indoor space, foundation insulation condition, and heat amount into the crawlspace, on the indoor thermal environment has been analyzed. Based on these analyses, the measured crawlspace heating system can make the average temperature of the living room above 20℃. These two houses have excellent thermal environment. According to the simulating result, heat amount input into crawlspace, which can make comfortable indoor thermal environment, for every month in heating period has been roughly concluded, and they are 600 W in December and March and 800 W in February and January, respectively.展开更多
文摘Based on the data of China Statistical Yearbooks, the current situation and development trend of the energy consumption of residential hot-water was discussed in this paper. Two hundred and sixty eight apartments were surveyed on the installation and operation situations of residential water heaters in five cities. Based on survey data, the proportion of pipeline heat loss was calculated in the energy consumption of a shower/bath. The influence factors of heat loss in residential hot-water pipeline network were discussed, and the measures were suggested for reducing the transport heat loss. The statistics and analysis conclusion have directive significance to reducing the transport heat loss.
基金Project(10YZ156) supported by Innovation Program of Shanghai Municipal Education Commission, China Project(sdl09009) supported by Training Program for Outstanding Youth Teacher of Shanghai Municipal Education Commission, China Project(Z2010-103) supported by Shanghai Education Development Foundation, China
文摘Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Based on the field study result, by using the simulation sol, ware, THERB, the effectiveness of the crawlspace warm air heating system has been examined. The effect of the factors, such as the wind amount circulating between crawlspace and indoor space, foundation insulation condition, and heat amount into the crawlspace, on the indoor thermal environment has been analyzed. Based on these analyses, the measured crawlspace heating system can make the average temperature of the living room above 20℃. These two houses have excellent thermal environment. According to the simulating result, heat amount input into crawlspace, which can make comfortable indoor thermal environment, for every month in heating period has been roughly concluded, and they are 600 W in December and March and 800 W in February and January, respectively.