双能X射线骨密度仪测定技术研究 被引量:7
1
作者 秦林林 陈金标 +3 位作者 张卫 马海波 葛崇华 肖艳霞 《原子能科学技术》 EI CAS CSCD 北大核心 1996年第3期230-235,共6页
以Lunar公司DPX-L型双能X射线骨密度仪为例,研究引起测量误差的主要因素并提出质控措施。用自检模块、腰椎体模评定仪器的体外测量精度好于1%。对10位志愿者重复2次测量,体内精度对腰椎,MPD(平均百分差)为0.... 以Lunar公司DPX-L型双能X射线骨密度仪为例,研究引起测量误差的主要因素并提出质控措施。用自检模块、腰椎体模评定仪器的体外测量精度好于1%。对10位志愿者重复2次测量,体内精度对腰椎,MPD(平均百分差)为0.46,CV变异系数)为0.75;对股骨颈,MPD为1.26、CV为0.47;Ward’s三角区MPD为2.01、CV为1.14;大转子MPD为1.66、CV为0.72。扫描图像由2位技术人员分析比由同1人分析时的误差大。测量对象体位重复和分析技术的规范化,是减小测量误差的2个重要的技术保障。为满足数据比对的需要,建议建立我国自己的体模标准。 展开更多
关键词 骨密度 双能X线吸收术 体外精度 体内精度
下载PDF
Evaluation of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification
2
作者 Ahmed Shawky Shawata Tarek El Nimr +1 位作者 Reda Ahmed Morsy Khaled M. Elshahat 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第7期343-349,共7页
Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent do... Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent dosimeters (TLD) is performed in many radiotherapy departments to verify the dose delivered during treatment. A total of 40 TLD divided into two batches (one of 20 and other of 20 TLD) were used. Different doses of Co6~ beam were delivered to the TLD chips at different depths. Diodes were irradiated at different depths in a (30 x 30 x 30) cm3 water slab phantom with various conditions of Field sizes, monitor units and SSDs. Results: The limitation of the in-vivo dosimetry technique is that dose can only be in system readout difficulty and type of readout (TLD system and diode) as the patient dose is directly measured. Several authors have investigated the measurements was 1.3%, with a standard deviation of 2.6%. Results were normally distributed around a mean as -0.39 and 0.34 respectively. After the evaluation of in vivo dosimetry brain case as an example, the mean doses for both eyes were 1.8%, with a standard deviation of 2.7%. These results are similar to studies conducted with diodes and TLD's. Conclusion: The diode is superior to TLD, since the diode measurements can be obtained on line and allows an immediate check. Other advantages of diodes include high sensitivity, good spatial resolution, and small size, simplicity of used. 展开更多
关键词 In vivo dosimetry uncertainty in experimental measurements calibration TLD dosimetry semi-conductor (di-ode) dosimetry
下载PDF