Methods and procedures of three-dimensional (3D) characterization of the pore structure features in the packed ore particle bed are focused. X-ray computed tomography was applied to deriving the cross-sectional imag...Methods and procedures of three-dimensional (3D) characterization of the pore structure features in the packed ore particle bed are focused. X-ray computed tomography was applied to deriving the cross-sectional images of specimens with single particle size of 1-2, 2-3, 3-4, 4-5, 5-6, 6-7, 7-8, 8-9, 9-10 ram. Based on the in-house developed 3D image analysis programs using Matlab, the volume porosity, pore size distribution and degree of connectivity were calculated and analyzed in detail. The results indicate that the volume porosity, the mean diameter of pores and the effective pore size (d50) increase with the increasing of particle size. Lognormal distribution or Gauss distribution is mostly suitable to model the pore size distribution. The degree of connectivity investigated on the basis of cluster-labeling algorithm also increases with increasing the particle size approximately.展开更多
Objective: To study the accuracy between CT and MRI in delineating gross tumor volume (GTV) of nasopharyngeal carcinoma (NPC) in making radiotherapy plan. Methods: The clinical data of 39 cases pathologically proven a...Objective: To study the accuracy between CT and MRI in delineating gross tumor volume (GTV) of nasopharyngeal carcinoma (NPC) in making radiotherapy plan. Methods: The clinical data of 39 cases pathologically proven as nasopharyngeal carcinoma selected from April 2003 to September 2004 were retrospectively analyzed. All were subjected to CT and MR examination one week before treatment. CT scanning was performed with GE Light speed 16, and axial scan was parallel to the OM line routinely from soft palate to the suprasellar cistern. MR scanning was performed by GE Signa super-conducting magnetic resonance imaging system (1.5 Tesla). The standard quadrature head coil was used. Routine axial, sagittal and coronal image with SE sequence were obtained, and FLAIR was used in 10 of 21 cases. Scanned field ranged from the soft palate to the suprasellar cistern. Part of all cases underwent enhanced scanned with Ultravist in CT group or/and GD-DTPA in MR group. All data were analyzed by using the paired-samples t test. Results: The media primary tumor volume (cm3) in CT group and MR group was 32.49±19.91, 29.06±18.75, respectively, and the difference between the two groups were significant (t=5.268, P=0.000). There was significant difference between the two groups in early stage (T1+T2) and advanced stage (T3+T4) by Fuzhou Staging System (t=5.677, P=0.000; t=3.310, P=0.005, respectively). There was significant difference in stage T1, T2, T3 (P=0.005, P=0.001, P=0.004, respectively), and not in stage T4 (P=0.146) between the two groups. Conclusion: MR was more accurate than CT in delineating GTV of NPC, so, is more valuable in making radiotherapy plan.展开更多
Objective To measure volume and other parameters of normal adrenal glands in Chinese adults with 64-slice multidetector CT, to evaluate the relationship of volume result with age, sex and body size, and to explore the...Objective To measure volume and other parameters of normal adrenal glands in Chinese adults with 64-slice multidetector CT, to evaluate the relationship of volume result with age, sex and body size, and to explore the correlations between adrenal volume and other measurements. Methods This study was based on 125 acquired contrast-enhanced upper abdominal CT scans performed with a 64-slice CT. The final study group consisted of 81 patients (49 males, 32 females). Portal venous phase images were studied for the measurements. Both the reconstruction interval and thickness were 1.5 mm. Each adrenal gland was outlined manually with computer-assistant technology to calculate its volume. The maximal sectional area, length, width and thickness of each adrenal gland were also measured. Results The mean age of total population was 47.9±13.0 (range: 20-76) years. The left, right, and total adrenal gland volumes were 4.23±0.74 (range: 2.85-5.83) cm 3 , 4.26±0.86 (2.59-6.56) cm 3 , and 8.50±1.40 (5.80-11.39) cm 3 , respectively. These volumes increased with weight (r=0.381, 0.389, and 0.437 respectively, all P<0.001), height (r=0.386, P<0.001; r=0.297, P=0.007; r=0.384, P<0.001) and body surface area (r=0.406, 0.392, and 0.452, all P<0.001). There was no significant difference in left, right or total adrenal volume with regard to sex after applying General Linear Model procedure to reduce the impact of weight (F=1.304, 0.064, and 0.597, all P>0.05), nor did volume change significantly with age (r=-0.033, -0.014, and -0.026, all P>0.05). Nearly all descriptors of bilateral adrenal glands correlated with ipsilateral volume except thickness (r=-0.027, P=0.814) and width (r=0.166, P=0.138) in the left side. Among these parameters, length had a stronger correlation with volume than others in the both left (r=0.412, P<0.001) and right (r=0.516, P<0.001) adrenal glands. Conclusion Our study has defined the volume distribution and other parameters of normal adrenal glands in Chinese adults, which provide a baseline for future studies.展开更多
We reported a special case of a locally advanced squamous cell carcinoma of the left lung. Due to pulmonary tuberculosis, the patient had underwent a complete right-side pulmonary lobectomy 20 years ago. Left lung sup...We reported a special case of a locally advanced squamous cell carcinoma of the left lung. Due to pulmonary tuberculosis, the patient had underwent a complete right-side pulmonary lobectomy 20 years ago. Left lung supports his life, he is unable to carry on an operation treatment, so he accepted radiotherapy. Firstly, we defined gross tumor volume (GTV1) by CT simulation location, three-dimensional conformal radiotherapy (3D-CRT) was used until tumor dose reached 50 Gy/25 f. Secondly, by repeating the planning CT scan, defined GTV2, continued to radiotherapy by 2.5 Gy/f until the dose was 65 Gy/31 f. Using the same method for third CT scan, defined GTV3, continued to radiotherapy by 3 Gy/f until the total dose was 74 Gy/34 f. After radiotherapy, the patient acquired complete response and he had no obvious side-effect of radiotherapy. There has been no recurrence for 5 years now.展开更多
基金Projects(50934002,51074013,51304076,51104100)supported by the National Natural Science Foundation of ChinaProject(IRT0950)supported by the Program for Changjiang Scholars Innovative Research Team in Universities,ChinaProject(2012M510007)supported by China Postdoctoral Science Foundation
文摘Methods and procedures of three-dimensional (3D) characterization of the pore structure features in the packed ore particle bed are focused. X-ray computed tomography was applied to deriving the cross-sectional images of specimens with single particle size of 1-2, 2-3, 3-4, 4-5, 5-6, 6-7, 7-8, 8-9, 9-10 ram. Based on the in-house developed 3D image analysis programs using Matlab, the volume porosity, pore size distribution and degree of connectivity were calculated and analyzed in detail. The results indicate that the volume porosity, the mean diameter of pores and the effective pore size (d50) increase with the increasing of particle size. Lognormal distribution or Gauss distribution is mostly suitable to model the pore size distribution. The degree of connectivity investigated on the basis of cluster-labeling algorithm also increases with increasing the particle size approximately.
基金This work was supported by a grant from the National Natural Science Foundation of China (No. 30470525).
文摘Objective: To study the accuracy between CT and MRI in delineating gross tumor volume (GTV) of nasopharyngeal carcinoma (NPC) in making radiotherapy plan. Methods: The clinical data of 39 cases pathologically proven as nasopharyngeal carcinoma selected from April 2003 to September 2004 were retrospectively analyzed. All were subjected to CT and MR examination one week before treatment. CT scanning was performed with GE Light speed 16, and axial scan was parallel to the OM line routinely from soft palate to the suprasellar cistern. MR scanning was performed by GE Signa super-conducting magnetic resonance imaging system (1.5 Tesla). The standard quadrature head coil was used. Routine axial, sagittal and coronal image with SE sequence were obtained, and FLAIR was used in 10 of 21 cases. Scanned field ranged from the soft palate to the suprasellar cistern. Part of all cases underwent enhanced scanned with Ultravist in CT group or/and GD-DTPA in MR group. All data were analyzed by using the paired-samples t test. Results: The media primary tumor volume (cm3) in CT group and MR group was 32.49±19.91, 29.06±18.75, respectively, and the difference between the two groups were significant (t=5.268, P=0.000). There was significant difference between the two groups in early stage (T1+T2) and advanced stage (T3+T4) by Fuzhou Staging System (t=5.677, P=0.000; t=3.310, P=0.005, respectively). There was significant difference in stage T1, T2, T3 (P=0.005, P=0.001, P=0.004, respectively), and not in stage T4 (P=0.146) between the two groups. Conclusion: MR was more accurate than CT in delineating GTV of NPC, so, is more valuable in making radiotherapy plan.
文摘Objective To measure volume and other parameters of normal adrenal glands in Chinese adults with 64-slice multidetector CT, to evaluate the relationship of volume result with age, sex and body size, and to explore the correlations between adrenal volume and other measurements. Methods This study was based on 125 acquired contrast-enhanced upper abdominal CT scans performed with a 64-slice CT. The final study group consisted of 81 patients (49 males, 32 females). Portal venous phase images were studied for the measurements. Both the reconstruction interval and thickness were 1.5 mm. Each adrenal gland was outlined manually with computer-assistant technology to calculate its volume. The maximal sectional area, length, width and thickness of each adrenal gland were also measured. Results The mean age of total population was 47.9±13.0 (range: 20-76) years. The left, right, and total adrenal gland volumes were 4.23±0.74 (range: 2.85-5.83) cm 3 , 4.26±0.86 (2.59-6.56) cm 3 , and 8.50±1.40 (5.80-11.39) cm 3 , respectively. These volumes increased with weight (r=0.381, 0.389, and 0.437 respectively, all P<0.001), height (r=0.386, P<0.001; r=0.297, P=0.007; r=0.384, P<0.001) and body surface area (r=0.406, 0.392, and 0.452, all P<0.001). There was no significant difference in left, right or total adrenal volume with regard to sex after applying General Linear Model procedure to reduce the impact of weight (F=1.304, 0.064, and 0.597, all P>0.05), nor did volume change significantly with age (r=-0.033, -0.014, and -0.026, all P>0.05). Nearly all descriptors of bilateral adrenal glands correlated with ipsilateral volume except thickness (r=-0.027, P=0.814) and width (r=0.166, P=0.138) in the left side. Among these parameters, length had a stronger correlation with volume than others in the both left (r=0.412, P<0.001) and right (r=0.516, P<0.001) adrenal glands. Conclusion Our study has defined the volume distribution and other parameters of normal adrenal glands in Chinese adults, which provide a baseline for future studies.
文摘We reported a special case of a locally advanced squamous cell carcinoma of the left lung. Due to pulmonary tuberculosis, the patient had underwent a complete right-side pulmonary lobectomy 20 years ago. Left lung supports his life, he is unable to carry on an operation treatment, so he accepted radiotherapy. Firstly, we defined gross tumor volume (GTV1) by CT simulation location, three-dimensional conformal radiotherapy (3D-CRT) was used until tumor dose reached 50 Gy/25 f. Secondly, by repeating the planning CT scan, defined GTV2, continued to radiotherapy by 2.5 Gy/f until the dose was 65 Gy/31 f. Using the same method for third CT scan, defined GTV3, continued to radiotherapy by 3 Gy/f until the total dose was 74 Gy/34 f. After radiotherapy, the patient acquired complete response and he had no obvious side-effect of radiotherapy. There has been no recurrence for 5 years now.