期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
口腔科污染源调查及防治措施探讨 被引量:4
1
作者 罗志勇 杨捷 陈刚 《生物医学工程学进展》 CAS 2016年第1期30-33,共4页
目的口腔门诊作为医院内感染的高发区,一直受到医护人员的广泛关注。在日常的牙科治疗中,口腔治疗台释出的水、气被大量的致病微生物和非致病微生物严重污染。多数传染病可以通过口腔就诊过程传播。污染微生物除来源于供给治疗台的气源... 目的口腔门诊作为医院内感染的高发区,一直受到医护人员的广泛关注。在日常的牙科治疗中,口腔治疗台释出的水、气被大量的致病微生物和非致病微生物严重污染。多数传染病可以通过口腔就诊过程传播。污染微生物除来源于供给治疗台的气源和水源外,还来源于牙钻手机在患者口腔内停转时的回吸作用。该文通过对口腔综合治疗台水路及气路系统等污染情况的调查,探讨改善口腔综合治疗台污染状况的方法,为临床上口腔科预防感染的管理提供依据。 展开更多
关键词 口腔科 供气系统污染 供水系统污染 感染控制
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
2
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the po... The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2) and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling) demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamilv residential buildings. 展开更多
关键词 Combined cooling heating and power (CCHP) Air-cooled microturbines Distributed energy generation Water for energy production Net metering
下载PDF
上一页 1 下一页 到第