Distortion is a technical indicator in the field of voice signal processing. The design is a portable distortion degree tester, based on Field-Progranmmble Gate Array (FleA, EP2C20) as the cote, using harmonic analy...Distortion is a technical indicator in the field of voice signal processing. The design is a portable distortion degree tester, based on Field-Progranmmble Gate Array (FleA, EP2C20) as the cote, using harmonic analysis method which better solve the distortion problem of acctwacy. It can achieve the signal transformation from the time-domain to the frequency-donkain, and is widely used for signal spectrum analysis. All the componets used in the design are low power, high perf-, low drift and industrial grade compionents. The reference voltage sources of ADC and DAC have identical performance of high stability, high precision. The dtr.k is the precise stable clock with FPGA temperature compensation. This project can get the cost-effective, high-precision, low power and portable design goals.展开更多
Fluorescent light-up probes comprising a tetraphenylethene unit with aggregation-induced emission(AIE)characteristics and a water-soluble peptide have been designed and synthesized which provide cell membrane and nucl...Fluorescent light-up probes comprising a tetraphenylethene unit with aggregation-induced emission(AIE)characteristics and a water-soluble peptide have been designed and synthesized which provide cell membrane and nuclear permeability to live cells.This strategy has offered new opportunities for the development of probes with light-up ability and good signal-to-noise ratio.The selectivity or targeting specificity is determined by the peptide sequence,i.e.a nuclear localization signal that leads to nucleus imaging and a cell biomarker targeting peptide that offers specific light-up imaging of HT-29 cells.展开更多
文摘Distortion is a technical indicator in the field of voice signal processing. The design is a portable distortion degree tester, based on Field-Progranmmble Gate Array (FleA, EP2C20) as the cote, using harmonic analysis method which better solve the distortion problem of acctwacy. It can achieve the signal transformation from the time-domain to the frequency-donkain, and is widely used for signal spectrum analysis. All the componets used in the design are low power, high perf-, low drift and industrial grade compionents. The reference voltage sources of ADC and DAC have identical performance of high stability, high precision. The dtr.k is the precise stable clock with FPGA temperature compensation. This project can get the cost-effective, high-precision, low power and portable design goals.
基金the Singapore National Research Foundation(R279-000-444-281)the Singapore-MIT Alliance for Research and Technology(R279-000-378-592)the Economic Development Board(Singapore-Peking-Oxford Research Enterprise,COY-15EWI-RCFSA/N197-1)
文摘Fluorescent light-up probes comprising a tetraphenylethene unit with aggregation-induced emission(AIE)characteristics and a water-soluble peptide have been designed and synthesized which provide cell membrane and nuclear permeability to live cells.This strategy has offered new opportunities for the development of probes with light-up ability and good signal-to-noise ratio.The selectivity or targeting specificity is determined by the peptide sequence,i.e.a nuclear localization signal that leads to nucleus imaging and a cell biomarker targeting peptide that offers specific light-up imaging of HT-29 cells.