期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
深空天线组阵相关合成算法的Simulink仿真与分析 被引量:5
1
作者 赵晓明 偶晓娟 +2 位作者 陈学军 李晶 魏瑞利 《电讯技术》 北大核心 2015年第5期509-515,共7页
为对深空网天线组阵中几种相关合成算法进行分析比较,构建了一种新的Simulink仿真模型。将其应用于某测控站天线组阵试验数据,验证了模型的可行性。在此仿真模型下,对Simple、Sumple和Matrix-free算法进行了频标同源/频标不同源、弱信号... 为对深空网天线组阵中几种相关合成算法进行分析比较,构建了一种新的Simulink仿真模型。将其应用于某测控站天线组阵试验数据,验证了模型的可行性。在此仿真模型下,对Simple、Sumple和Matrix-free算法进行了频标同源/频标不同源、弱信号/强信号、2/3/6个天线等组阵情况下的仿真分析。三种算法在频标同源情况下的合成效率均优于不同源的情况;强信号组阵情况下,三种算法的信噪比合成性能基本相当;Simple算法在6天线情况下,信噪比合成性能下降;Sumple算法在组阵的天线数目很少时,合成信噪比较低且不稳定,在天线数目较多时性能良好;Matrix-free算法性能稳健,合成效率始终大于95%。该Simulink仿真模型对于进行天线组阵信号相关算法的分析具有一定的价值。 展开更多
关键词 深空网 测控 天线组阵 信号相关算法 SIMULINK仿真 合成效率
下载PDF
Transverse flowmetry of carbon particles based on photoacoustic Doppler standard deviation using an auto-correlation method
2
作者 卢涛 孙丽君 《Optoelectronics Letters》 EI 2015年第3期226-228,共3页
In order to measure the flow velocity of carbon particle suspension perpendicular to the receiving axis of ultrasound transducer, the standard deviation of photoacoustic Doppler frequency spectrum is used to estimate ... In order to measure the flow velocity of carbon particle suspension perpendicular to the receiving axis of ultrasound transducer, the standard deviation of photoacoustic Doppler frequency spectrum is used to estimate the bandwidth broadening, and the spectrum standard deviation is calculated by an auto-correlation method. A 532 nm pulsed laser with the repetition rate of 20 Hz is used as a pumping source to generate photoacoustic signal. The photoacoustic signals are detected using a focused PZT ultrasound transducer with the central frequency of 10 MHz. The suspension of carbon particles is driven by a syringe pump. The complex photoacoustic signal is calculated by Hilbert transformation from time domain signal before auto-correlation. The standard deviation of the Doppler bandwidth broadening is calculated by averaging the auto-correlation results of several individual A scans. The feasibility of the proposed method is demonstrated by measuring the spectrum standard deviation of the transversal carbon particle flow from 5.0 mm/s to 8.4 mrn/s. The experimental results show that the auto-correlation result is approximately linearly distributed within the measuring range. 展开更多
关键词 BANDWIDTH Carbon Correlation methods Flow velocity Mathematical transformations Optical pumping Pumping (laser) STATISTICS Time domain analysis Transducers Ultrasonic propagation Ultrasonic scattering Ultrasonic transducers
原文传递
上一页 1 下一页 到第