This paper presents the studies of the refining of IKONOS-2 RPC, the transform of the datum, the mode of the control point distribution and the method of IKONOS stereo triangulation, so that IKONOS imagery can be used...This paper presents the studies of the refining of IKONOS-2 RPC, the transform of the datum, the mode of the control point distribution and the method of IKONOS stereo triangulation, so that IKONOS imagery can be used to collect the precise geospatial data and produce the large scale map.The transform between the IKONOS-2 image space and the national coordinate system based on the RPC have been developed, and the results of block adjustment with various control schemes in a practical project near Himalayas have been examined and analysed. The encouraging results of high positioning accuracy have been obtained.展开更多
Research indicates that high levels of sedentary behavior(sitting or lying with low energy expenditure) are adversely associated with health. A key factor in improving our understanding of the impact of sedentary beha...Research indicates that high levels of sedentary behavior(sitting or lying with low energy expenditure) are adversely associated with health. A key factor in improving our understanding of the impact of sedentary behavior(and patterns of sedentary time accumulation) on health is the use of objective measurement tools that collect date and time-stamped activity information. One such tool is the activP AL monitor. This thigh-worn device uses accelerometer-derived information about thigh position to determine the start and end of each period spent sitting/lying, standing, and stepping, as well as stepping speed, step counts, and postural transitions. The activP AL is increasingly being used within field-based research for its ability to measure sitting/lying via posture. We summarise key issues to consider when using the activP AL in physical activity and sedentary behavior field-based research with adult populations. It is intended that the findings and discussion points be informative for researchers who are currently using activP AL monitors or are intending to use them. Pre-data collection decisions, monitor preparation and distribution, data collection considerations, and manual and automated data processing possibilities are presented using examples from current literature and experiences from 2 research groups from the UK and Australia.展开更多
Quantitative security metrics are desirable for measuring the performance of information security controls. Security metrics help to make functional and business decisions for improving the performance and cost of the...Quantitative security metrics are desirable for measuring the performance of information security controls. Security metrics help to make functional and business decisions for improving the performance and cost of the security controls. However, defining enterprise-level security metrics has already been listed as one of the hard problems in the Info Sec Research Council's hard problems list. Almost all the efforts in defining absolute security metrics for the enterprise security have not been proved fruitful. At the same time, with the maturity of the security industry, there has been a continuous emphasis from the regulatory bodies on establishing measurable security metrics. This paper addresses this need and proposes a relative security metric model that derives three quantitative security metrics named Attack Resiliency Measure(ARM), Performance Improvement Factor(PIF), and Cost/Benefit Measure(CBM) for measuring the performance of the security controls. For the effectiveness evaluation of the proposed security metrics, we took the secure virtual machine(VM) migration protocol as the target of assessment. The virtual-ization technologies are rapidly changing the landscape of the computing world. Devising security metrics for virtualized environment is even more challenging. As secure virtual machine migration is an evolving area and no standard protocol is available specifically for secure VM migration. This paper took the secure virtual machine migration protocol as the target of assessment and applied the proposed relative security metric model for measuring the Attack Resiliency Measure, Performance Improvement Factor, and Cost/Benefit Measure of the secure VM migration protocol.展开更多
In this study, we analyzed the swing motions of more experienced practitioner and new practitioner of iaido players by using tri-axial acceleration sensor and gyro sensor. Iaido is a modern Japanese martial art/sport....In this study, we analyzed the swing motions of more experienced practitioner and new practitioner of iaido players by using tri-axial acceleration sensor and gyro sensor. Iaido is a modern Japanese martial art/sport. In this way, the acceleration and gyro sensor measurement enabled detailed motion information at the installation points to be displayed in a short time, thus making it possible to easily extract the objective problems. Although it was not possible to confirm by the acceleration and angular velocity measurements the detailed motion of the entire body as obtained in the 2D motion analysis with a high-speed camera, it was confirmed that the acceleration and gyro sensor is an evaluation means that can be installed easily and can provide the exercise information in a short time as an objective index.展开更多
基金Funded by the Western Region Transport Development Science and Technology Program (No.2002 318 0050).
文摘This paper presents the studies of the refining of IKONOS-2 RPC, the transform of the datum, the mode of the control point distribution and the method of IKONOS stereo triangulation, so that IKONOS imagery can be used to collect the precise geospatial data and produce the large scale map.The transform between the IKONOS-2 image space and the national coordinate system based on the RPC have been developed, and the results of block adjustment with various control schemes in a practical project near Himalayas have been examined and analysed. The encouraging results of high positioning accuracy have been obtained.
基金supported by the National Institute for Health Researsch (NIHR) DietLifestyle & Physical Activity Biomedical Research Unit based at University Hospitals of Leicester and Loughborough University+5 种基金the National Institute for Health Research Collaboration for Leadership in Applied Health Research and Care-East Midlands (NIHR CLAHRC- EM)the Leicester Clinical Trials Unitsupported by a National Health and Medical Research Council (NHMRC) Centre for Research Excellence Grant on Sitting Time and Chronic Disease Prevention-Measurement, Mechanisms and Interventions (APP1057608)supported by a Heart Foundation Postdoctoral (PH 12B 7054)NHMRC Career Development (#1086029) Fellowshipsupported by an Australian Research Council Future Fellowship (FTE 100100918)
文摘Research indicates that high levels of sedentary behavior(sitting or lying with low energy expenditure) are adversely associated with health. A key factor in improving our understanding of the impact of sedentary behavior(and patterns of sedentary time accumulation) on health is the use of objective measurement tools that collect date and time-stamped activity information. One such tool is the activP AL monitor. This thigh-worn device uses accelerometer-derived information about thigh position to determine the start and end of each period spent sitting/lying, standing, and stepping, as well as stepping speed, step counts, and postural transitions. The activP AL is increasingly being used within field-based research for its ability to measure sitting/lying via posture. We summarise key issues to consider when using the activP AL in physical activity and sedentary behavior field-based research with adult populations. It is intended that the findings and discussion points be informative for researchers who are currently using activP AL monitors or are intending to use them. Pre-data collection decisions, monitor preparation and distribution, data collection considerations, and manual and automated data processing possibilities are presented using examples from current literature and experiences from 2 research groups from the UK and Australia.
文摘Quantitative security metrics are desirable for measuring the performance of information security controls. Security metrics help to make functional and business decisions for improving the performance and cost of the security controls. However, defining enterprise-level security metrics has already been listed as one of the hard problems in the Info Sec Research Council's hard problems list. Almost all the efforts in defining absolute security metrics for the enterprise security have not been proved fruitful. At the same time, with the maturity of the security industry, there has been a continuous emphasis from the regulatory bodies on establishing measurable security metrics. This paper addresses this need and proposes a relative security metric model that derives three quantitative security metrics named Attack Resiliency Measure(ARM), Performance Improvement Factor(PIF), and Cost/Benefit Measure(CBM) for measuring the performance of the security controls. For the effectiveness evaluation of the proposed security metrics, we took the secure virtual machine(VM) migration protocol as the target of assessment. The virtual-ization technologies are rapidly changing the landscape of the computing world. Devising security metrics for virtualized environment is even more challenging. As secure virtual machine migration is an evolving area and no standard protocol is available specifically for secure VM migration. This paper took the secure virtual machine migration protocol as the target of assessment and applied the proposed relative security metric model for measuring the Attack Resiliency Measure, Performance Improvement Factor, and Cost/Benefit Measure of the secure VM migration protocol.
文摘In this study, we analyzed the swing motions of more experienced practitioner and new practitioner of iaido players by using tri-axial acceleration sensor and gyro sensor. Iaido is a modern Japanese martial art/sport. In this way, the acceleration and gyro sensor measurement enabled detailed motion information at the installation points to be displayed in a short time, thus making it possible to easily extract the objective problems. Although it was not possible to confirm by the acceleration and angular velocity measurements the detailed motion of the entire body as obtained in the 2D motion analysis with a high-speed camera, it was confirmed that the acceleration and gyro sensor is an evaluation means that can be installed easily and can provide the exercise information in a short time as an objective index.