期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
关于拓扑空间紧性的研究 被引量:2
1
作者 赵秀恒 白占立 《河北师范大学学报(自然科学版)》 CAS 1999年第1期27-29,32,共4页
论述了拓扑空间各种紧性的定义及其相互关系,分析了紧性对空间性质的影响.讨论了拓扑空间局部紧。
关键词 拓扑空间 致性 局部 信紧
下载PDF
Usefulness of dynamic contrast-enhanced MR imaging in the evaluation of pulmonary isolated lesions 被引量:3
2
作者 Zhiyong Li Tingting Zhang Jianlin Wu Wei Liu Qiang Wei Bin Xu Rui Han 《The Chinese-German Journal of Clinical Oncology》 CAS 2010年第6期334-336,共3页
Objective: The aim of our study was to investigate the value of dynamic contrast-enhanced MRI for evaluating differential diagnosis of pulmonary isolated lesions. Methods: Twenty-nine consecutive patients enrolled i... Objective: The aim of our study was to investigate the value of dynamic contrast-enhanced MRI for evaluating differential diagnosis of pulmonary isolated lesions. Methods: Twenty-nine consecutive patients enrolled in this study, all of whom underwent DCE-MRI examinations and received a histologic and clinical diagnosis. Among these, lung tuberculoma 7 cases, harmatoma 3 cases, peripheral lung cancer 19 cases. DCE-MRI was acquired with 3D LAVA technique, total 18 phases were acquired, scanner time of per phase was 5-7″. After contrasting agent, twice successive scanning was acquired at 10″ and 50″. Then 1′30″, 2′, 2′30″, 3′, 3′30″, 4′, 5′, 6′, 7′, 8′, 9′, 10′, 11′, 12′ performed scanning. Region of interest was placed on the Maximum level in the tumors. According to Schaefer's standard, four types of time signal intensity curve (TIC) were classified, which were A, B, C and D. Compared the dynamic parameters between benign and malignant nodules. Results: Lung tuberculoma may display three curves: A type 1 case, ring-shaped enhancement 4 cases (periphery ring A type, central region D type), D type 2 cases. Harmatoma may display three curves: A type 1 case, C type 2 case. Peripheral lung cancer may display A type. Except 2 cases D type lung tuberculoma, we compared curve data of 8 cases benign nodules (including tuberculoma Atype and periphery ring Atype, harmatoma Atype and C type) and lung cancer. SlEP%: benign nodules 0.7885 ±0.5543, lung cancer 1.2623 ±0.3059, P 〈 0.05; MER: benign nodules 1.0007 ± 0.4251, lung cancer 1.3694 ±0.2740, P 〈 0.05; washout: P 〉 0.05. Conclusion: Lung MR imaging is helpful to diagnosis and differential diagnosis of isolated benign and malignant nodules. SIEP% and MER could offer valuable information. The evolution of global tuberculosis may be from A type to ring-shaped ennoblement to D type. It was easy to do right diagnosis to lung tuberculoma with ring-shaped ennoblement and D type. Peripheral lung cancer commonly displayed A type and needed identification with acute inflammation. So, it is important to anti-inflammatory follow-up for a few A type nodules. 展开更多
关键词 non-small cell lung carcinoma dynamic contrast-enhanced MRI time signal intensity curve diagnosis
下载PDF
COMPACT SUPPORT THIN PLATE SPLINE ALGORITHM 被引量:1
3
作者 Li Jing Yang Xuan Yu Jianping 《Journal of Electronics(China)》 2007年第4期515-522,共8页
Common tools based on landmarks in medical image elastic registration are Thin Plate Spline (TPS) and Compact Support Radial Basis Function (CSRBF). TPS forces the corresponding landmarks to exactly match each other a... Common tools based on landmarks in medical image elastic registration are Thin Plate Spline (TPS) and Compact Support Radial Basis Function (CSRBF). TPS forces the corresponding landmarks to exactly match each other and minimizes the bending energy of the whole image. However, in real application, such scheme would deform the image globally when deformation is only local. CSRBF needs manually determine the support size, although its deformation is limited local. Therefore, to limit the effect of the deformation, new Compact Support Thin Plate Spline algorithm (CSTPS) is approached, analyzed and applied. Such new approach gains optimal mutual information, which shows its registration result satisfactory. The experiments also show it can apply in both local and global elastic registration. 展开更多
关键词 Thin Plate Spline (TPS) Image registration Mutual information Compact support
下载PDF
Design of 4.25 Gbps Small Form-factor Pluggable(SFP) Transceiver 被引量:1
4
作者 HU Wei WANG Li LIU Bi-Chen 《Semiconductor Photonics and Technology》 CAS 2009年第1期56-62,共7页
Compact, hot-pluggable, and data-agnostic, SFP modules bring up to 4.25 Gbps to a flexible new form factor. The SFP transceiver which is the core device of optical communication is always the research focus in the fie... Compact, hot-pluggable, and data-agnostic, SFP modules bring up to 4.25 Gbps to a flexible new form factor. The SFP transceiver which is the core device of optical communication is always the research focus in the field of optical communication for both telecommunication and data communication applications. The working principles of SFP including the transmitter components, the receiver components and the microcontroller are discussed in detail. The basic theory of high-speed signal and the concept of high - speed circuit, high-speed board design techniques are presented. A new design of high performance, cost effective SFP transceiver and PCB layout are also presented. The performance of the transceiver is analyzed and the characteristics of the sample are coincident with the expected ones. The status of the transceiver can be monitored and controlled by F C bus through the interface in real time. This transceiver can meet the requirement of SFF-8472. 展开更多
关键词 SFP digital diagnostic monitoring high-speed digital circuit IZC bus
下载PDF
Design of EPS Testing System Based on LabVIEW2012
5
作者 LIU Fang-gang LIU Xi 《International English Education Research》 2014年第5期62-64,共3页
The article designed a set of automatic test system of automobiles EPS based on LabVIEW, which can collect current signal and torque signal when emergency braking. It consists of two parts: hardware and software. Har... The article designed a set of automatic test system of automobiles EPS based on LabVIEW, which can collect current signal and torque signal when emergency braking. It consists of two parts: hardware and software. Hardware includes sensors,condition circuits, data acquisition card and your computer. Software-related programs, including an analysis of acquisition signal processing and storage display.The system is stable and reliable by contrast verification. 展开更多
关键词 signal acquisition EPS TEST SYSTEM LABVIEW
下载PDF
Feasibility investigation on deep ocean compact autonomous Raman spectrometer developed for in-situ detection of acid radical ions 被引量:10
6
作者 杜增丰 李颖 +2 位作者 陈靓 郭金家 郑荣儿 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2015年第2期545-550,共6页
A newly developed Deep Ocean Compact Autonomous Raman Spectrometer (DOCARS) system is introduced and used for in-situ detection of acid radical ions in this paper. To evaluate the feasibility and capability of DOCAR... A newly developed Deep Ocean Compact Autonomous Raman Spectrometer (DOCARS) system is introduced and used for in-situ detection of acid radical ions in this paper. To evaluate the feasibility and capability of DOCARS for quantitative analysis of the acid radical ions in the deep ocean, extensive investigations have been carried out both in laboratory and sea trials during the development phase. In the laboratory investigations, Raman spectra of the prepared samples (acid radical ions solutions) were obtained, and analyzed using the method of internal standard normalization in data processing. The Raman signal of acid radical ions was normalized by that of water molecules. The calibration curve showed that the normalized Raman signal intensity of SO4^2-, NO3^-, and HCO^-3 increases linearly as the concentration rises with correlation coefficient R^2 of 0.99, 0.99, and 0.98 respectively. The linear function obtained from the calibration curve was then used for the analysis of the spectra ,data acquired in the sea trial under a simulating chemical field in the deep-sea environment. It was found that the detected concentration of NO3 according to the linear function can reflect the concentration changes of NO~ after the sample was released, and the detection accuracy of the DOCARS system for SO^2-_4 is 8%. All the results showed that the DOCARS system has great potential in quantitative detection of acid radical ions under the deep-sea environment, while the sensitivity of the DOCARS system is expected to be improved. 展开更多
关键词 laser Raman spectroscopy Deep Ocean Compact Autonomous Raman Spectrometer (DOCARS) acid radical ions
下载PDF
ROLE OF CALCINEURIN IN ANGIOTENSIN II- INDUCED CARDIAC MYOCYTE HYPERTROPHY OF RATS 被引量:1
7
作者 符民桂 张继峰 +3 位作者 许松 庞永政 刘乃奎 唐朝枢 《Chinese Medical Sciences Journal》 CAS CSCD 2001年第1期1-4,共4页
The present study investigated the role of calcineurin in angiotensin II(AngII)- induced cardiac myocyte hypertrophy of rats. Method. The primary cardiac myocytes were cultured under the standard conditions. The calci... The present study investigated the role of calcineurin in angiotensin II(AngII)- induced cardiac myocyte hypertrophy of rats. Method. The primary cardiac myocytes were cultured under the standard conditions. The calcineurin activity in AngII- treated cardiomyocytes was tested by using PNPP;protein synethsis rate was assessed by 3H- leucine incorporation; atrial natriuretic factor(ANF) mRNA level was determined by Northern blot analysis. Cell viability was estimated by lactate dehydrogenase(LDH) levels in cultured medium and by dyed cell numbers. Result. After stimulation of 10,100 and 1 000nmol/L of AngII, calcineurin activities in the cardiomyocytes were increased by 13% ,57% (P Conclusion. During AngII- induced cardiac myocyte hypertrophy, calcineurin signal pathway is activated, and inhibition of the pathway can attenuate AngII- induced cardiac myocyte hypertrophy, which suggests that the calcineurin signal pathway may play an important role in AngII- induced myocardial hypertrophy of rats. 展开更多
关键词 CALCINEURIN angiotensin II cardiac hypertrophy signal transduction
下载PDF
SELF-ADAPTIVE CONTROLS OF A COMPLEX CELLULAR SIGNALING TRANSDUCTION SYSTEM 被引量:4
8
作者 LIHong ZHOUZhiyuan DAIRongyang LUOBo ZHENGXiaoli YANGWenli HETao WUMinglu 《Journal of Systems Science & Complexity》 SCIE EI CSCD 2004年第3期349-368,共20页
In cells, the interactions of distinct signaling transduction pathways originating from cross-talkings between signaling molecules give rise to the formation of signaling transduction networks, which contributes to th... In cells, the interactions of distinct signaling transduction pathways originating from cross-talkings between signaling molecules give rise to the formation of signaling transduction networks, which contributes to the changes (emergency) of kinetic behaviors of signaling system compared with single molecule or pathway. Depending on the known experimental data, we have constructed a model for complex cellular signaling transduction system, which is derived from signaling transduction of epidermal growth factor receptor in neuron. By the computational simulating methods, the self-adaptive controls of this system have been investigated. We find that this model exhibits a relatively stable selfadaptive system, especially to over-stimulation of agonist, and the amplitude and duration of signaling intermediates in it could be controlled by multiple self-adaptive effects, such as 'signal scattering', 'positive feedback', 'negative feedback' and 'B-Raf shunt'. Our results provide an approach to understanding the dynamic behaviors of complex biological systems. 展开更多
关键词 biological complexity self-adaptive system EMERGENCY computer simulation cellular signaling transduction
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部