The reliability and maintainability of electrical system of drum shearer at Parvade. 1 Coal Mine in central Iran was analyzed. The maintenance and failure data were collected during 19 months of shearer operation. Acc...The reliability and maintainability of electrical system of drum shearer at Parvade. 1 Coal Mine in central Iran was analyzed. The maintenance and failure data were collected during 19 months of shearer operation. According to trend and serial correlation tests, the data were independent and identically distributed (iid) and therefore the statistical techniques were used for modeling. The data analysis show that the time between failures (TBF) and time to repair (TTR) data obey the lognormal and Weibull 3 parameters distribution respectively. Reliability-based preventive maintenance time intervals for electrical system of the drum shearer were calculated with regard to reliability plot. The reliability-based maintenance intervals for 90%, 80%, 70% and 50% reliability level are respectively 9.91, 17.96, 27.56 and 56.1 h. Also the calculations show that time to repair (TTR) of this system varies in range 0.17-4 h with 1.002 h as mean time to repair (MTTR). There is a 80% chance that the electrical system of shearer of Parvade. 1 mine repair will be accomplished within 1.45 h.展开更多
The increasing number of pathological occurrences is found in reinforced concrete structures, so does the demand for inspection and maintenance services in residential communities in the state of Pernambuco, which aim...The increasing number of pathological occurrences is found in reinforced concrete structures, so does the demand for inspection and maintenance services in residential communities in the state of Pernambuco, which aim to detect damage to the structure in a timely manner to minimize repair costs, thus applying preventive maintenance in order to guarantee the estimated useful life of the project for the building. However, it is observed that the practice of periodic inspections is not yet part of the culture of a certain segment of the population that does not have economic means and knowledge of the importance of maintenance to ensure the integrity of the structure. It was used in this work an inspection script with use of tests and methodology to quantify damage and to check the state of degradation of two residential buildings with more than 20 years and built near the seafront where environmental aggression is strong. The deterioration found in each of the buildings has been differentiated due to different corrective maintenance performed at every building. The last maintenance, performed in Building A, was performed by corrective hand of unskilled labour guided by the community itself, which has no expertise in the field of civil engineering. In Building B, the situation is similar, compounded by the opinion of some tenants that there is no need for this routine, even the structure being in critical condition, as was confirmed with the application of the methodology employ. There should be a legislation that governs the execution of inspections and maintenance programs in addition to the existing technical standards. The methodologies presented suitable for checking the degree of degradation of the structures and performed tests confirmed the diagnosis obtained by visual inspection and quantification of damage.展开更多
文摘The reliability and maintainability of electrical system of drum shearer at Parvade. 1 Coal Mine in central Iran was analyzed. The maintenance and failure data were collected during 19 months of shearer operation. According to trend and serial correlation tests, the data were independent and identically distributed (iid) and therefore the statistical techniques were used for modeling. The data analysis show that the time between failures (TBF) and time to repair (TTR) data obey the lognormal and Weibull 3 parameters distribution respectively. Reliability-based preventive maintenance time intervals for electrical system of the drum shearer were calculated with regard to reliability plot. The reliability-based maintenance intervals for 90%, 80%, 70% and 50% reliability level are respectively 9.91, 17.96, 27.56 and 56.1 h. Also the calculations show that time to repair (TTR) of this system varies in range 0.17-4 h with 1.002 h as mean time to repair (MTTR). There is a 80% chance that the electrical system of shearer of Parvade. 1 mine repair will be accomplished within 1.45 h.
文摘The increasing number of pathological occurrences is found in reinforced concrete structures, so does the demand for inspection and maintenance services in residential communities in the state of Pernambuco, which aim to detect damage to the structure in a timely manner to minimize repair costs, thus applying preventive maintenance in order to guarantee the estimated useful life of the project for the building. However, it is observed that the practice of periodic inspections is not yet part of the culture of a certain segment of the population that does not have economic means and knowledge of the importance of maintenance to ensure the integrity of the structure. It was used in this work an inspection script with use of tests and methodology to quantify damage and to check the state of degradation of two residential buildings with more than 20 years and built near the seafront where environmental aggression is strong. The deterioration found in each of the buildings has been differentiated due to different corrective maintenance performed at every building. The last maintenance, performed in Building A, was performed by corrective hand of unskilled labour guided by the community itself, which has no expertise in the field of civil engineering. In Building B, the situation is similar, compounded by the opinion of some tenants that there is no need for this routine, even the structure being in critical condition, as was confirmed with the application of the methodology employ. There should be a legislation that governs the execution of inspections and maintenance programs in addition to the existing technical standards. The methodologies presented suitable for checking the degree of degradation of the structures and performed tests confirmed the diagnosis obtained by visual inspection and quantification of damage.