To gain a deep insight into the hot drawing process of aluminum alloy sheet, simulations of cylindrical cup drawing at elevated temperatures were carried out with experimental validation. The influence of four importa...To gain a deep insight into the hot drawing process of aluminum alloy sheet, simulations of cylindrical cup drawing at elevated temperatures were carried out with experimental validation. The influence of four important process parameters, namely,punch velocity, blank holder force(BHF), friction coefficient and initial forming temperature of blank on drawing characteristics(i.e.minimum thickness and thickness deviation) was investigated with the help of design of experiments(DOE), analysis of variance(ANOVA) and analysis of mean(ANOM). Based on the results of ANOVA, it is shown that the blank holder force has the greatest influence on minimum thickness. The importance of punch velocity for thickness deviation is 44.35% followed by BHF of 24.88%,friction coefficient of 15.77% and initial forming temperature of blank of 14.995%. After determining the significance of each factor on forming characteristics, how the individual parameter affects characteristics was further analyzed by ANOM.展开更多
Controlling the biogas fermentation process is the key for maintaining stable operation of biogas system and increasing gas yield. Aiming at features of biogas fermentation process and difficulties of control, a pract...Controlling the biogas fermentation process is the key for maintaining stable operation of biogas system and increasing gas yield. Aiming at features of biogas fermentation process and difficulties of control, a practical control scheme is proposed combining the abundant experience of biogas experts. And it discussed the structural design and hardware configuration of the expert control system, established the database and role base, and designed the control strategy of production system inference. The design scheme with ZigBee and PDA technology as core is employed so as to solve problems of environmental factor detection and data transfer management. The test result shows that the deviation of temperature is controlled within ± 0.9℃, the deviation of pH is controlled within ±0.3, the deviation of oxidation-reduction potential is controlled within ±30mV, the deviation of gas production is controlled within ± 9mL and that of methane concentration is controlled within ±4.5%. This system is easily expandable and applicable to biogas engineering at various scales.展开更多
A new kinetic spectrophotometric method has been developed for the determination of trace Ni (Ⅱ in natural water. The method is based on the catalytic effect of Ni (Ⅱ) on the oxidation of weak acid brilliant blue...A new kinetic spectrophotometric method has been developed for the determination of trace Ni (Ⅱ in natural water. The method is based on the catalytic effect of Ni (Ⅱ) on the oxidation of weak acid brilliant blue dye (RAWL) by KIO4 in acid medium. The concentration of nickel (Ⅱ) can be determined spectrophotometrically by measuring the decrease of absorbance of RAWL at λ = 626 nm using the fix-time method. The influencing factors are investigated by the orthogonal experimental design. The obtained optimum analytical conditions are: pH = 2.00, CRAWL = 5.00×10^-5 mol·L^-1, c KlO4 = 2.00× 10^-5 mol·L^-1, the reaction time t= 10min and the temperature T = 25 ℃. Under the optimum conditions, the developed method allows the measurement of Ni (Ⅱ) in a range of 0 - 40.0ngmL1. The standard deviation of eleven independent measurements of blank reaction is S = 3.08× 10^-3 and the limit of detection is 2.20ng·mL^-1. The relative standard deviations (RSDs) in six replicate determinations of 5 ngmL-1 and 8 ngmL1 Ni (Ⅱ) are 2.87% and 1.11%, respectively. Moreover, the experiments show few cations and anions can interfere with the measurement of Ni (Ⅱ). The recovery efficiencies of this method are in a range of 97.0%-102.5% in freshwater samples. But there is a decreasing effect, which is about 0.2 times the added Ni (Ⅱ) in seawater medium. After reasonable calibration this processing method is used for the determination of Ni (Ⅱ) in seawater samples successfully. The results show this developed method has high accuracy and precision, high sensitivity, large range of linearity and high speed. The method can, therefore, be employed at room temperature.展开更多
基金Project(2009ZX04014-074)supported by the National High Technology Research and Development Program of ChinaProject(20120006110017)supported by Doctoral Fund Program of Ministry of Education of ChinaProject(P2014-15)supported by State Key Laboratory of Materials Processing and Die & Mould Technology(Huazhong University of Science and Technology),China
文摘To gain a deep insight into the hot drawing process of aluminum alloy sheet, simulations of cylindrical cup drawing at elevated temperatures were carried out with experimental validation. The influence of four important process parameters, namely,punch velocity, blank holder force(BHF), friction coefficient and initial forming temperature of blank on drawing characteristics(i.e.minimum thickness and thickness deviation) was investigated with the help of design of experiments(DOE), analysis of variance(ANOVA) and analysis of mean(ANOM). Based on the results of ANOVA, it is shown that the blank holder force has the greatest influence on minimum thickness. The importance of punch velocity for thickness deviation is 44.35% followed by BHF of 24.88%,friction coefficient of 15.77% and initial forming temperature of blank of 14.995%. After determining the significance of each factor on forming characteristics, how the individual parameter affects characteristics was further analyzed by ANOM.
文摘Controlling the biogas fermentation process is the key for maintaining stable operation of biogas system and increasing gas yield. Aiming at features of biogas fermentation process and difficulties of control, a practical control scheme is proposed combining the abundant experience of biogas experts. And it discussed the structural design and hardware configuration of the expert control system, established the database and role base, and designed the control strategy of production system inference. The design scheme with ZigBee and PDA technology as core is employed so as to solve problems of environmental factor detection and data transfer management. The test result shows that the deviation of temperature is controlled within ± 0.9℃, the deviation of pH is controlled within ±0.3, the deviation of oxidation-reduction potential is controlled within ±30mV, the deviation of gas production is controlled within ± 9mL and that of methane concentration is controlled within ±4.5%. This system is easily expandable and applicable to biogas engineering at various scales.
文摘A new kinetic spectrophotometric method has been developed for the determination of trace Ni (Ⅱ in natural water. The method is based on the catalytic effect of Ni (Ⅱ) on the oxidation of weak acid brilliant blue dye (RAWL) by KIO4 in acid medium. The concentration of nickel (Ⅱ) can be determined spectrophotometrically by measuring the decrease of absorbance of RAWL at λ = 626 nm using the fix-time method. The influencing factors are investigated by the orthogonal experimental design. The obtained optimum analytical conditions are: pH = 2.00, CRAWL = 5.00×10^-5 mol·L^-1, c KlO4 = 2.00× 10^-5 mol·L^-1, the reaction time t= 10min and the temperature T = 25 ℃. Under the optimum conditions, the developed method allows the measurement of Ni (Ⅱ) in a range of 0 - 40.0ngmL1. The standard deviation of eleven independent measurements of blank reaction is S = 3.08× 10^-3 and the limit of detection is 2.20ng·mL^-1. The relative standard deviations (RSDs) in six replicate determinations of 5 ngmL-1 and 8 ngmL1 Ni (Ⅱ) are 2.87% and 1.11%, respectively. Moreover, the experiments show few cations and anions can interfere with the measurement of Ni (Ⅱ). The recovery efficiencies of this method are in a range of 97.0%-102.5% in freshwater samples. But there is a decreasing effect, which is about 0.2 times the added Ni (Ⅱ) in seawater medium. After reasonable calibration this processing method is used for the determination of Ni (Ⅱ) in seawater samples successfully. The results show this developed method has high accuracy and precision, high sensitivity, large range of linearity and high speed. The method can, therefore, be employed at room temperature.