As one of the most important geometric parameters for a PC-type fiber connector end face, apex offset can contribute to high insertion loss and high back-reflection reading. A novel measurement method for the paramete...As one of the most important geometric parameters for a PC-type fiber connector end face, apex offset can contribute to high insertion loss and high back-reflection reading. A novel measurement method for the parameter, connector rotating-π method, is proposed. With the method, the apex offset of a common connector end face is measured. The result is compared with that measured by a Norland 3000 fiber connector end face interferometer. It is found that the difference between two results is 1.8μm. Meantime, the influences of relevant error resources on apex offset measurement under rotating-π method and apex-core method are respectively analyzed, and two error equations are derived. The analytical result shows that, compared with apex-core method, if two additional sub-tilts of axis within and in the direction perpendicular to principal plane caused by its rotation are not bigger than the original axis tilt angle, the max. measurement error will then be reduced by at least 22.5% with rotating-π method. The practicability of the method is confirmed by the experiments.展开更多
[Objective]The aim was to find a way to measure the cholesterol content in deserted oil.[Method]Dual-wavelength spectrophotometry method was used for the determination of cholesterol in edible oil.630 nm and 720 nm we...[Objective]The aim was to find a way to measure the cholesterol content in deserted oil.[Method]Dual-wavelength spectrophotometry method was used for the determination of cholesterol in edible oil.630 nm and 720 nm were set as target band and reference band in this method,respectively.The result was compared to liquid chromatography method.[Result]The relative standard deviation(RSD)was at 1.26% and recovery was between 101.9% and 110.7%.Linear range was 8.0-40.0 μg/ml.The tested result was close to the result of liquid chromatography.[Conclusion]It was proved that this method was easy,fast and accurate.The disturbance of sitosterol was eliminated without isolation.It can be used for fast identification of the authenticity of waste fat.展开更多
基金Research Projects of Nanjing University of Science and Technology
文摘As one of the most important geometric parameters for a PC-type fiber connector end face, apex offset can contribute to high insertion loss and high back-reflection reading. A novel measurement method for the parameter, connector rotating-π method, is proposed. With the method, the apex offset of a common connector end face is measured. The result is compared with that measured by a Norland 3000 fiber connector end face interferometer. It is found that the difference between two results is 1.8μm. Meantime, the influences of relevant error resources on apex offset measurement under rotating-π method and apex-core method are respectively analyzed, and two error equations are derived. The analytical result shows that, compared with apex-core method, if two additional sub-tilts of axis within and in the direction perpendicular to principal plane caused by its rotation are not bigger than the original axis tilt angle, the max. measurement error will then be reduced by at least 22.5% with rotating-π method. The practicability of the method is confirmed by the experiments.
基金Supported by National Quality Inspection Bureau(KJ092102,2009QK146)
文摘[Objective]The aim was to find a way to measure the cholesterol content in deserted oil.[Method]Dual-wavelength spectrophotometry method was used for the determination of cholesterol in edible oil.630 nm and 720 nm were set as target band and reference band in this method,respectively.The result was compared to liquid chromatography method.[Result]The relative standard deviation(RSD)was at 1.26% and recovery was between 101.9% and 110.7%.Linear range was 8.0-40.0 μg/ml.The tested result was close to the result of liquid chromatography.[Conclusion]It was proved that this method was easy,fast and accurate.The disturbance of sitosterol was eliminated without isolation.It can be used for fast identification of the authenticity of waste fat.