针对中国石油化工股份有限公司广州分公司的1.5 Mt/a S Zorb装置,考察了影响装置长周期平稳运行的因素。采取使用国产高通量滤芯及在转剂线上使用耐磨管件,对再生取热盘管进行改造,对闭锁料斗程控阀进行预防性维修等措施解决了装置长周...针对中国石油化工股份有限公司广州分公司的1.5 Mt/a S Zorb装置,考察了影响装置长周期平稳运行的因素。采取使用国产高通量滤芯及在转剂线上使用耐磨管件,对再生取热盘管进行改造,对闭锁料斗程控阀进行预防性维修等措施解决了装置长周期运行瓶颈,实现了在95.06%设计负荷工况下连续平稳运行超过49个月的目标,关键设备反应器过滤器运行超过4 a,期间压差未超过30 kPa。展开更多
Reduction of sulfur content in FCC gasoline was studied in a fixed fluid bed (FFB) unit by using metal-modified LV-23 FCC catalyst. The results showed that the sulfur content in FCC gasoline could be reduced with LV-2...Reduction of sulfur content in FCC gasoline was studied in a fixed fluid bed (FFB) unit by using metal-modified LV-23 FCC catalyst. The results showed that the sulfur content in FCC gasoline could be reduced with LV-23 catalyst modified with zinc, palladium, zinc-palladium, zinc-cobalt, and zinc-nickel. Among these metals or metal combinations, palladium-containing catalyst was the most effective. Desulfurization of the heavy fraction of FCC gasoline was more effective than full-range gasoline under the same conditions with palladium-containing catalysts. A high reaction temperature was favorable to desulfurization, but it would reduce the yield of liquid product. After desulfurization reaction, the olefin content of product gasoline decreased while the aromatic and iso-alkane contents increased. Removal of thiophene and benzothiophene is higher.展开更多
This article refers to the procedure for selection, evaluation and development of the LADS-D desorption agent associated with the LADS-A adsorbent used in the non-hydroprocessing adsorptive desulfurization (LADS) proc...This article refers to the procedure for selection, evaluation and development of the LADS-D desorption agent associated with the LADS-A adsorbent used in the non-hydroprocessing adsorptive desulfurization (LADS) process for FCC naphtha developed by LPEC Refining Research Institute. The LADS-D desorption agent can effectively remove the sulfides adsorbed on the LADS-A adsorbent. The saturated LADS-A adsorbent can be instantly regenerated by the LADS-D desorption agent to recover its adsorption activity. The LADS-D desorption agent can not only effectively remove all impurities adsorbed on the adsorbent, but also has strong ability to dissolve the impurities to keep a stable desorption efficiency of adsorbent to be basically commensurate with fresh adsorbent after extended use.展开更多
文摘Reduction of sulfur content in FCC gasoline was studied in a fixed fluid bed (FFB) unit by using metal-modified LV-23 FCC catalyst. The results showed that the sulfur content in FCC gasoline could be reduced with LV-23 catalyst modified with zinc, palladium, zinc-palladium, zinc-cobalt, and zinc-nickel. Among these metals or metal combinations, palladium-containing catalyst was the most effective. Desulfurization of the heavy fraction of FCC gasoline was more effective than full-range gasoline under the same conditions with palladium-containing catalysts. A high reaction temperature was favorable to desulfurization, but it would reduce the yield of liquid product. After desulfurization reaction, the olefin content of product gasoline decreased while the aromatic and iso-alkane contents increased. Removal of thiophene and benzothiophene is higher.
文摘This article refers to the procedure for selection, evaluation and development of the LADS-D desorption agent associated with the LADS-A adsorbent used in the non-hydroprocessing adsorptive desulfurization (LADS) process for FCC naphtha developed by LPEC Refining Research Institute. The LADS-D desorption agent can effectively remove the sulfides adsorbed on the LADS-A adsorbent. The saturated LADS-A adsorbent can be instantly regenerated by the LADS-D desorption agent to recover its adsorption activity. The LADS-D desorption agent can not only effectively remove all impurities adsorbed on the adsorbent, but also has strong ability to dissolve the impurities to keep a stable desorption efficiency of adsorbent to be basically commensurate with fresh adsorbent after extended use.