Conventional seismic exploration,mostly based on reflection theory,hardly has accurate imaging results for disaster geologic bodies which have small scale,steep dip,or complex structure.In this paper,we design two typ...Conventional seismic exploration,mostly based on reflection theory,hardly has accurate imaging results for disaster geologic bodies which have small scale,steep dip,or complex structure.In this paper,we design two typical geologic models for analyzing the characteristics of scattered waves in mines for forward modeling by finite difference and apply the equivalent offset migration(EOM)and EOM-based interference stack migration methods to mine prospecting.We focus on the analysis of scatted imaging’s technological superiority to reflection imaging.Research shows:1)scattered imaging can improve fold and make the best of weak scattered information,so it shows better results than post-stack migration imaging and 2)it can utilize the diffraction stack migration method-based ray path theory for mine seismic advanced prediction,so it provides an new efficient imaging method for improving resolution of mine seismic exploration.展开更多
To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat i...To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat is scanned by using the system with individual high voltage, tube current, filter thickness, and exposure time. A model is presented based on the Monte Carlo code PENELOPE for generating the X-ray spectra of X-ray tube used in the micro-CT system. A platform developed based on Matlab allows for calculating beam quality parameters, including the average energy of X-ray beam, the change of transmition rate and the input X-ray fluence. The factors affecting the signal difference to noise ratio (SDNR) of micro-CT are investigated and the relationship between SDNR and scan combinations is analyzed. A series of tools and methods are developed for small animal imaging and imaging performance evaluation in the field of small animal imaging.展开更多
基金supported financially by the National Key Project(Grant No.2008ZX05035)the 973 Program(Grant No. 2009CB219603 and 2007CB209406)the National Natural Science Foundation of China(Grant No.50974081)
文摘Conventional seismic exploration,mostly based on reflection theory,hardly has accurate imaging results for disaster geologic bodies which have small scale,steep dip,or complex structure.In this paper,we design two typical geologic models for analyzing the characteristics of scattered waves in mines for forward modeling by finite difference and apply the equivalent offset migration(EOM)and EOM-based interference stack migration methods to mine prospecting.We focus on the analysis of scatted imaging’s technological superiority to reflection imaging.Research shows:1)scattered imaging can improve fold and make the best of weak scattered information,so it shows better results than post-stack migration imaging and 2)it can utilize the diffraction stack migration method-based ray path theory for mine seismic advanced prediction,so it provides an new efficient imaging method for improving resolution of mine seismic exploration.
基金Supported by the National Natural Science Foundation of China (60672104,10527003)the Nation-al Basic Research Program of China ("973"Program)(2006CB705705)the Joint Research Foundation of Beijing Mu-nicipal Commission of Education (JD100010607)~~
文摘To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat is scanned by using the system with individual high voltage, tube current, filter thickness, and exposure time. A model is presented based on the Monte Carlo code PENELOPE for generating the X-ray spectra of X-ray tube used in the micro-CT system. A platform developed based on Matlab allows for calculating beam quality parameters, including the average energy of X-ray beam, the change of transmition rate and the input X-ray fluence. The factors affecting the signal difference to noise ratio (SDNR) of micro-CT are investigated and the relationship between SDNR and scan combinations is analyzed. A series of tools and methods are developed for small animal imaging and imaging performance evaluation in the field of small animal imaging.