Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 m...Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 male, 7 female, average age 59.4±13.2 years) with pathologically diagnosed pancreatic cancer were enrolled. All patients received an abdominal scan using a dual source CT scanner 7 to 31 days before biopsy or surgery. After injection of iodine contrast agent, arterial and pancreatic parenchyma phase were scanned consequently, using a dual-energy scan mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs) in the pancreatic parenchyma phase. A series of derived dual-energy datasets were evaluated including non-liner blending (non-linear blending width 0-500 HU; blending center -500 to 500 HU), mono-energetic (40-190 keV), 100 kVp and 140 kVp. On each datasets, mean CT values of the pancreatic parenchyma and tumor, as well as standard deviation CT values of subcutaneous fat and psoas muscle were measured. Regions of interest of cutaneous fat and major psoas muscle of 100 kVp and 140 kVp images were calculated. Best CNR of subcutaneous fat (CNR F ) and CNR of the major psoas muscle (CNR M ) of non-liner blending and mono-energetic datasets were calculated with the optimal mono-energetic keV setting and the optimal blending center/width setting for the best CNR. One Way ANOVA test was used for comparison of best CNR between different dual-energy derived datasets. Results The best CNR F (4.48±1.29) was obtained from the non-liner blending datasets at blending center -16.6±103.9 HU and blending width 12.3±10.6 HU. The best CNR F (3.28±0.97) was obtained from the mono-energetic datasets at 73.3±4.3 keV. CNR F in the 100 kVp and 140 kVp were 3.02±0.91 and 1.56±0.56 respectively. Using fat as the noise background, all of these images series showed significant differences (P<0.01) except best CNR F of mono-energetic image sets vs. CNR F of 100 kVp image (P=0.460). Similar results were found using muscle as the noise background (mono-energetic image vs. 100 kVp image: P=0.246; mono-energetic image vs. non-liner blending image: P=0.044; others: P<0.01). Conclusion Compared with mono-energetic datasets and low kVp datasets, non-linear blending image at automatically chosen blending width/window provides better tumor to the pancreas CNR, which might be beneficial for better detection of pancreatic tumors.展开更多
The diagnosis of inflammatory bowel disease(IBD) depends on direct endoscopic visualization of the colonic and ileal mucosa and the histological study of the obtained samples.Radiological and scintigraphic methods are...The diagnosis of inflammatory bowel disease(IBD) depends on direct endoscopic visualization of the colonic and ileal mucosa and the histological study of the obtained samples.Radiological and scintigraphic methods are mainly used as an adjunct to endoscopy.In this review,we focus on the diagnostic potential of nuclear medicine procedures.The value of all radiotracers is described with special reference to those with greater experience and more satisfactory results.Tc-99m hexamethylpropylene amine oxime white blood cells remain a widely acceptable scintigraphic method for the diagnosis of IBD,as well as for the evaluation of disease extension and severity.Recently,pentavalent Tc-99m dimercaptosuccinic acid has been recommended as an accurate variant and a complementary technique to endoscopy for the follow-up and assessment of disease activity.Positron emission tomography alone or with computed tomography using fluorine-18 fluorodeoxyglucose appears to be a promising method of measuring inflammation in IBD patients.展开更多
文摘Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 male, 7 female, average age 59.4±13.2 years) with pathologically diagnosed pancreatic cancer were enrolled. All patients received an abdominal scan using a dual source CT scanner 7 to 31 days before biopsy or surgery. After injection of iodine contrast agent, arterial and pancreatic parenchyma phase were scanned consequently, using a dual-energy scan mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs) in the pancreatic parenchyma phase. A series of derived dual-energy datasets were evaluated including non-liner blending (non-linear blending width 0-500 HU; blending center -500 to 500 HU), mono-energetic (40-190 keV), 100 kVp and 140 kVp. On each datasets, mean CT values of the pancreatic parenchyma and tumor, as well as standard deviation CT values of subcutaneous fat and psoas muscle were measured. Regions of interest of cutaneous fat and major psoas muscle of 100 kVp and 140 kVp images were calculated. Best CNR of subcutaneous fat (CNR F ) and CNR of the major psoas muscle (CNR M ) of non-liner blending and mono-energetic datasets were calculated with the optimal mono-energetic keV setting and the optimal blending center/width setting for the best CNR. One Way ANOVA test was used for comparison of best CNR between different dual-energy derived datasets. Results The best CNR F (4.48±1.29) was obtained from the non-liner blending datasets at blending center -16.6±103.9 HU and blending width 12.3±10.6 HU. The best CNR F (3.28±0.97) was obtained from the mono-energetic datasets at 73.3±4.3 keV. CNR F in the 100 kVp and 140 kVp were 3.02±0.91 and 1.56±0.56 respectively. Using fat as the noise background, all of these images series showed significant differences (P<0.01) except best CNR F of mono-energetic image sets vs. CNR F of 100 kVp image (P=0.460). Similar results were found using muscle as the noise background (mono-energetic image vs. 100 kVp image: P=0.246; mono-energetic image vs. non-liner blending image: P=0.044; others: P<0.01). Conclusion Compared with mono-energetic datasets and low kVp datasets, non-linear blending image at automatically chosen blending width/window provides better tumor to the pancreas CNR, which might be beneficial for better detection of pancreatic tumors.
文摘The diagnosis of inflammatory bowel disease(IBD) depends on direct endoscopic visualization of the colonic and ileal mucosa and the histological study of the obtained samples.Radiological and scintigraphic methods are mainly used as an adjunct to endoscopy.In this review,we focus on the diagnostic potential of nuclear medicine procedures.The value of all radiotracers is described with special reference to those with greater experience and more satisfactory results.Tc-99m hexamethylpropylene amine oxime white blood cells remain a widely acceptable scintigraphic method for the diagnosis of IBD,as well as for the evaluation of disease extension and severity.Recently,pentavalent Tc-99m dimercaptosuccinic acid has been recommended as an accurate variant and a complementary technique to endoscopy for the follow-up and assessment of disease activity.Positron emission tomography alone or with computed tomography using fluorine-18 fluorodeoxyglucose appears to be a promising method of measuring inflammation in IBD patients.