期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
内蒙古盐海子盐湖Ya02孔元素聚散与古气候变化 被引量:4
1
作者 刘振敏 陈延成 +4 位作者 王鉴津 魏东岩 关绍曾 钱作华 杨清堂 《化工矿产地质》 CAS 1996年第2期101-108,共8页
通过对内蒙古伊克昭盟Ya02孔35件样品Al、Fe、K、Na、Ca、Mg、F、Cl以及Ti、Mn、Ba等22项元素测试结果的研究表明,元素组合与含量变化过程严格受气候因素的控制,并反应敏感。据此将该湖自下而上划分了1... 通过对内蒙古伊克昭盟Ya02孔35件样品Al、Fe、K、Na、Ca、Mg、F、Cl以及Ti、Mn、Ba等22项元素测试结果的研究表明,元素组合与含量变化过程严格受气候因素的控制,并反应敏感。据此将该湖自下而上划分了13个气候期,揭示了自成湖(23kaB.P.)以来冷暖与干湿的气候环境变化模式:晚更新世主要以冷湿气候为主,并伴有多次相对温干偏湿的气候波动;早全新世为暖湿气候;中全新世以温暖干气候为主,伴有冷湿气候;晚全新世以来,所测各元素含量趋于增高趋势。 展开更多
关键词 元素聚散 古气候变化 内蒙古 盐海子盐湖 湖泊
下载PDF
Quantitative analysis of elements (C,N,O,Al,Si and Fe) in polyamide with wavelength dispersive X-ray fluorescence spectrometry 被引量:3
2
作者 LAI MeiShuang XIANG LeiWen +1 位作者 LIN Jin-Ming LI Hai-Fang 《Science China Chemistry》 SCIE EI CAS 2013年第8期1164-1170,共7页
A wavelength dispersive X-ray fluorescence (WD-XRF) spectrometry combined with calibration curve method was estab- lished for simultaneously analyzing low-Z elements (C, N, O) and A1, Si, Fe in polyamide. To inves... A wavelength dispersive X-ray fluorescence (WD-XRF) spectrometry combined with calibration curve method was estab- lished for simultaneously analyzing low-Z elements (C, N, O) and A1, Si, Fe in polyamide. To investigate the origin of plastic material causing deposition and blocking in instrument engines and pipelines, polyamide 6 (PA 6, an engineering plastic) was chosen as the study object on account of its common use in industry. The sample preparation with pressed powder disk has been developed for determination of six elements in PA 6. Pure Cu metal was used as the matrix and PA 6 was regarded as standard sample for C, N, O elements. PA 6 particles were firstly smashed to uniform powder in liquid nitrogen, and then mixed with inorganic standard powders (Fe203, A1203, SIO2, and Na2SiO3). The mixture was ground to obtain homogeneous calibration materials for WD-XRF analysis. The quantitative property of the calibration curve method for each element was re- liable. The limits of detection (S/N≤3) of C, N, O, A1, Si and Fe using WD-XRF were 249, 120, 101, 6.2, 3.3, and 1.8 μg/g, respectively. To confirm the accuracy of the proposed WD-XRF calibration curve method, inductively coupled plasma optical emission spectroscopy (ICP-OES) detection for A1, Si, Fe and elemental analyzer (EA) analysis for C, N, O were utilized. A good correlation of the WD-XRF results with the measurements of ICP-OES and EA was observed. 展开更多
关键词 X-ray fluorescence low-Z elements polyamide 6
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部