Abstract: A joint solution model of variabk:-mass flow in two-phase region and fluid-solid coupling heat transfer, concerned about the charge process of variable-mass thermodynamic system, is built up and calculated...Abstract: A joint solution model of variabk:-mass flow in two-phase region and fluid-solid coupling heat transfer, concerned about the charge process of variable-mass thermodynamic system, is built up and calculated by the finite element method (FEM). The results are basically consistent with relative experimental data. The calculated average heat transfer coefficient reaches 1.7~105 W/(m2. K). When the equal percentage valve is used, the system needs the minimum requirements of valve control, but brings the highest construction cost. With the: decrease of initial steam pressure, the heat transfer intensity also weakens but the steam flow increases. With the initial water filling coefficient increasing or the temperature of steam supply decreasing, the amount of accumulative steam flow increases with the growth of steam pressure. When the pressure of steam supply drops, the steam flow gradient increases during the maximum opening period of control valve, and causes the maximum steam flow to increase.展开更多
The Merguellil catchment (central Tunisia) has undergone rapid hydrological changes over the last decades. The most visible signs are a marked decrease in surface runoff in the upstream catchment and a complete chan...The Merguellil catchment (central Tunisia) has undergone rapid hydrological changes over the last decades. The most visible signs are a marked decrease in surface runoff in the upstream catchment and a complete change in the recharge processes of the Kairouan aquifer downstream. Fluctuations in rainfall have had a real but limited hydrological impact. Much more important are the consequences of human activities such as soil and water conservation works, small and large dams, pumping for irrigation. Several independent approaches were implemented: hydrodynamics, thermal surveys, geochemistry including isotopes. They helped to identify the different terms of the regional water balance and to characterize their changes over time.展开更多
The inverted charge structure formation of a hailstorm was investigated using the Advanced Weather Research and Forecasting(WRF-ARW) model coupled with electrification and discharge schemes. Different processes may ...The inverted charge structure formation of a hailstorm was investigated using the Advanced Weather Research and Forecasting(WRF-ARW) model coupled with electrification and discharge schemes. Different processes may be responsible for inverted charge structure in different storms and regions.A dynamical-derived mechanism of inverted charge structure formation was confirmed by the numerical model: the inverted structure was formed by strong updraft and downdraft under normal-polarity charging conditions such that the graupel charged negatively in the main charging region in the middle-upper level of the cloud. The simulation results showed the storm presented a normal charge structure before and after hail-fall; while during the hail-fall stage, it showed an inverted charge structure—negative charge region in the upper level of the cloud and a positive charge region in the middle level of the cloud—appearing at the front edge near the strong updraft in the hailstorm. The charging processes between the two particles mainly occurred at the top of the cloud, where the graupel charged negatively and ice crystals positively due to the strong updraft. When the updraft air reached the top of the storm, it would spread to the rear and front. The light ice crystals were transported backward and forward more easily. Meanwhile, the positively charged ice crystals were transported downward by the frontal subsidence, and then a positive charge region formed between the -10°C and -25°C levels. Subsequently, a negative charge region materialized in the upper level of the cloud, and the inverted charge structure formed.展开更多
基金Project(20080431380) supported by China Postdoctoral Science Foundation
文摘Abstract: A joint solution model of variabk:-mass flow in two-phase region and fluid-solid coupling heat transfer, concerned about the charge process of variable-mass thermodynamic system, is built up and calculated by the finite element method (FEM). The results are basically consistent with relative experimental data. The calculated average heat transfer coefficient reaches 1.7~105 W/(m2. K). When the equal percentage valve is used, the system needs the minimum requirements of valve control, but brings the highest construction cost. With the: decrease of initial steam pressure, the heat transfer intensity also weakens but the steam flow increases. With the initial water filling coefficient increasing or the temperature of steam supply decreasing, the amount of accumulative steam flow increases with the growth of steam pressure. When the pressure of steam supply drops, the steam flow gradient increases during the maximum opening period of control valve, and causes the maximum steam flow to increase.
文摘The Merguellil catchment (central Tunisia) has undergone rapid hydrological changes over the last decades. The most visible signs are a marked decrease in surface runoff in the upstream catchment and a complete change in the recharge processes of the Kairouan aquifer downstream. Fluctuations in rainfall have had a real but limited hydrological impact. Much more important are the consequences of human activities such as soil and water conservation works, small and large dams, pumping for irrigation. Several independent approaches were implemented: hydrodynamics, thermal surveys, geochemistry including isotopes. They helped to identify the different terms of the regional water balance and to characterize their changes over time.
基金supported by the National Key Basic Research and Development Program of China (Grant No. 2014CB441406)the National Natural Science Foundation of China (Grant Nos. 91537209 & 41405005)the Basic Research Fund of Chinese Academy of Meteorological Sciences (Grant No. 2014R017)
文摘The inverted charge structure formation of a hailstorm was investigated using the Advanced Weather Research and Forecasting(WRF-ARW) model coupled with electrification and discharge schemes. Different processes may be responsible for inverted charge structure in different storms and regions.A dynamical-derived mechanism of inverted charge structure formation was confirmed by the numerical model: the inverted structure was formed by strong updraft and downdraft under normal-polarity charging conditions such that the graupel charged negatively in the main charging region in the middle-upper level of the cloud. The simulation results showed the storm presented a normal charge structure before and after hail-fall; while during the hail-fall stage, it showed an inverted charge structure—negative charge region in the upper level of the cloud and a positive charge region in the middle level of the cloud—appearing at the front edge near the strong updraft in the hailstorm. The charging processes between the two particles mainly occurred at the top of the cloud, where the graupel charged negatively and ice crystals positively due to the strong updraft. When the updraft air reached the top of the storm, it would spread to the rear and front. The light ice crystals were transported backward and forward more easily. Meanwhile, the positively charged ice crystals were transported downward by the frontal subsidence, and then a positive charge region formed between the -10°C and -25°C levels. Subsequently, a negative charge region materialized in the upper level of the cloud, and the inverted charge structure formed.