An improved automatic voltage coordination control strategy (AVCCS) based on ;automatic voltage control (AVC) and battery energy storage control (BESC) is proposed for photovoltaic grid-connected system (PVGS)...An improved automatic voltage coordination control strategy (AVCCS) based on ;automatic voltage control (AVC) and battery energy storage control (BESC) is proposed for photovoltaic grid-connected system (PVGS) to mitigate the voltage fluctuations caused by environmental disturbances. Only AVC is used when small environ- mental disturbances happen, while BESC is incorporated with AVC to restrain the voltage fluctuations when large disturbances happen. An adjustable parameter determining the allowed amplitudes of voltage fluctuations is introduced to realize the above switching process. A benchmark low voltage distribution system including ]?VGS is established by using the commercial software Dig SILENT. Simulation results show that the voltage under AVCCS satisfies the IEEE Standard 1547, and the installed battery capacity is also reduced. Meanwhile, the battery's service life is ex- tended by avoiding frequent charges/discharges in the control process.展开更多
Recently, the number of system interconnection of the renewable energy such as PV (photovoltaic) generation system and wind power generation system has been increasing drastically. A distribution system with the dis...Recently, the number of system interconnection of the renewable energy such as PV (photovoltaic) generation system and wind power generation system has been increasing drastically. A distribution system with the distributed generation must be operated keeping reliability of power supply and power quality. When high-capacity PV systems are interconnected to the distribution system, the system voltages may be deviated from the upper limit or lower limit of proper voltage in the distribution system. In this study, the authors propose a cooperative voltage control method of the distribution system by the power factor control of plural residential PV systems. In order to verify the validity of the proposal method, the numerical calculations are carried out by using an analytical model of distribution system which interconnected residential PV systems.展开更多
Nowadays, in a household PV (photovoltaic) generation system, it is generally connecting PV modules in series and then output to the power-conditioner. However, when PV modules are mismatched, it will lead to a wron...Nowadays, in a household PV (photovoltaic) generation system, it is generally connecting PV modules in series and then output to the power-conditioner. However, when PV modules are mismatched, it will lead to a wrong MPPT (maximum power point tracking) to all modules and a power decreasing of the whole system. Aiming at this problem, this paper presents the idea which improves the MPPT without changing the conventional power-conditioner, by adding a Buck type DC-DC (direct current) converter behind each module. Simulations of PSIM (power simulation) and experiments are taken to prove this theory. The result shows that, by this idea, the generated power of the conventional PV generation system can be greatly increased under the condition of mismatch.展开更多
The quantity of installed PV (photovoltaic) systems in the German distribution grid is still increasing. In some areas, the installed PV capacity exceeds 5 kW per HC (house connection). Therefore, the load flow ch...The quantity of installed PV (photovoltaic) systems in the German distribution grid is still increasing. In some areas, the installed PV capacity exceeds 5 kW per HC (house connection). Therefore, the load flow changes its characteristics and leads to new requirements for the grid. In some areas, the power feedback is higher than the delivery and the installed PV capacity becomes the decisive factor for grid planning. This paper discusses the impact of PV systems on the flicker level. The focus hereby is on the correlation among the flicker level, the grid voltage and the meteorological parameters. Different approaches to investigate if there is an influence of PV systems on the maximum flicker are taken into account. Furthermore, an investigation if the normative limit is exceeded will be shown.展开更多
基金Supported by National Basic Research Program of China ("973" Program,No. 2009CB219701 and No. 2010CB234608)Tianjin Municipal Science and Technology Development Program (No. 09JCZDJC25000)Specialized Research Fund for Doctor Discipline of Ministry of Education of China (No. 20090032110064)
文摘An improved automatic voltage coordination control strategy (AVCCS) based on ;automatic voltage control (AVC) and battery energy storage control (BESC) is proposed for photovoltaic grid-connected system (PVGS) to mitigate the voltage fluctuations caused by environmental disturbances. Only AVC is used when small environ- mental disturbances happen, while BESC is incorporated with AVC to restrain the voltage fluctuations when large disturbances happen. An adjustable parameter determining the allowed amplitudes of voltage fluctuations is introduced to realize the above switching process. A benchmark low voltage distribution system including ]?VGS is established by using the commercial software Dig SILENT. Simulation results show that the voltage under AVCCS satisfies the IEEE Standard 1547, and the installed battery capacity is also reduced. Meanwhile, the battery's service life is ex- tended by avoiding frequent charges/discharges in the control process.
文摘Recently, the number of system interconnection of the renewable energy such as PV (photovoltaic) generation system and wind power generation system has been increasing drastically. A distribution system with the distributed generation must be operated keeping reliability of power supply and power quality. When high-capacity PV systems are interconnected to the distribution system, the system voltages may be deviated from the upper limit or lower limit of proper voltage in the distribution system. In this study, the authors propose a cooperative voltage control method of the distribution system by the power factor control of plural residential PV systems. In order to verify the validity of the proposal method, the numerical calculations are carried out by using an analytical model of distribution system which interconnected residential PV systems.
文摘Nowadays, in a household PV (photovoltaic) generation system, it is generally connecting PV modules in series and then output to the power-conditioner. However, when PV modules are mismatched, it will lead to a wrong MPPT (maximum power point tracking) to all modules and a power decreasing of the whole system. Aiming at this problem, this paper presents the idea which improves the MPPT without changing the conventional power-conditioner, by adding a Buck type DC-DC (direct current) converter behind each module. Simulations of PSIM (power simulation) and experiments are taken to prove this theory. The result shows that, by this idea, the generated power of the conventional PV generation system can be greatly increased under the condition of mismatch.
文摘The quantity of installed PV (photovoltaic) systems in the German distribution grid is still increasing. In some areas, the installed PV capacity exceeds 5 kW per HC (house connection). Therefore, the load flow changes its characteristics and leads to new requirements for the grid. In some areas, the power feedback is higher than the delivery and the installed PV capacity becomes the decisive factor for grid planning. This paper discusses the impact of PV systems on the flicker level. The focus hereby is on the correlation among the flicker level, the grid voltage and the meteorological parameters. Different approaches to investigate if there is an influence of PV systems on the maximum flicker are taken into account. Furthermore, an investigation if the normative limit is exceeded will be shown.