Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change tradi...Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change traditional manual way of shaft alignment and to make the measurement easier and more accurate. The system is comprised of two small measuring units (laser transmitter and detector) and a PDA (Personal Digital Assistant) with measurement software. The laser alignment system with dual PSDs was improved on a single PSD system, and yields higher measurement accuracy than the previous design, and has been successful for designing and implements actual shaft alignment. In the system, the range of offset measurement is ±4 mm, and the resolution is 1.5 μm, with accuracy being less than 2 μm.展开更多
A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity er...A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.展开更多
A single cesium atom is trapped in a far-off-resonance optical dipole trap (FORT) from the magneto-optical trap (MOT) and directly imaged by using a charge-coupled device (CCD) camera. The binary single-atom ste...A single cesium atom is trapped in a far-off-resonance optical dipole trap (FORT) from the magneto-optical trap (MOT) and directly imaged by using a charge-coupled device (CCD) camera. The binary single-atom steps and photon anti-bunching are observed by a photon-counting-based HBT system using fluorescence light. The average atom dwelling time in the FORT is about 9 s. To reduce the background noise in the detection procedure we employ a weak probe laser tuned to the D1 line to il- lurninate the single atom from the direction perpendicular to the large-numerical-aperture collimation system. The second or- der degree of coherence g(2)(r)=0.12_+0.02 is obtained directly from the fluorescence light of the single atom without deducting the background. The background light has been suppressed to 10 counts per 50 ms, which is much lower compared with the reported results. The measured g(2)(r) is in good agreement with theoretical analysis. The system provides a simple and effi- cient method to manipulate and measure single neutral atoms, and opens a way to create an efficient controlled single-photon source.展开更多
基金Project (No. 60337030) partly supported by the National NaturalScience Foundation of China
文摘Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change traditional manual way of shaft alignment and to make the measurement easier and more accurate. The system is comprised of two small measuring units (laser transmitter and detector) and a PDA (Personal Digital Assistant) with measurement software. The laser alignment system with dual PSDs was improved on a single PSD system, and yields higher measurement accuracy than the previous design, and has been successful for designing and implements actual shaft alignment. In the system, the range of offset measurement is ±4 mm, and the resolution is 1.5 μm, with accuracy being less than 2 μm.
文摘A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.
基金supported by the State Basic Key Research Program of China (Grant No. 2012CB921601)China National Funds for Distinguished Young Scientists (Grant No. 11125418)the National Natural Science Foundation of China (Grant Nos. 10974125,61121064 and60978017)
文摘A single cesium atom is trapped in a far-off-resonance optical dipole trap (FORT) from the magneto-optical trap (MOT) and directly imaged by using a charge-coupled device (CCD) camera. The binary single-atom steps and photon anti-bunching are observed by a photon-counting-based HBT system using fluorescence light. The average atom dwelling time in the FORT is about 9 s. To reduce the background noise in the detection procedure we employ a weak probe laser tuned to the D1 line to il- lurninate the single atom from the direction perpendicular to the large-numerical-aperture collimation system. The second or- der degree of coherence g(2)(r)=0.12_+0.02 is obtained directly from the fluorescence light of the single atom without deducting the background. The background light has been suppressed to 10 counts per 50 ms, which is much lower compared with the reported results. The measured g(2)(r) is in good agreement with theoretical analysis. The system provides a simple and effi- cient method to manipulate and measure single neutral atoms, and opens a way to create an efficient controlled single-photon source.