Ibuprofen is widely used as a non-steroidal anti-inflammatory drug and produced as racemic mixture. Its pharmacological activity resides only in S-(+)-enantiomer, and R-()-enantiomer is not only inactive but also has ...Ibuprofen is widely used as a non-steroidal anti-inflammatory drug and produced as racemic mixture. Its pharmacological activity resides only in S-(+)-enantiomer, and R-()-enantiomer is not only inactive but also has many side effects. Thus it is necessary to separate R-enantiomer from racemic ibuprofen. We studied optical separation of racemic Ibuprofen with chiral high performance liquid chromatography (HPLC). Out of three different chiral stationary phases, which were selected on the basis of structure and availability, two were found to be ef-fective. There was optimum eluent composition for each stationary phase for good resolution in optical separation. Resolution decreased with increase of eluent flow rate, but effect of injection volume on resolution was insignificant at high eluent flow rate.展开更多
Enantiomer separation is one of the most important prerequisites for the investigation of environmental enantioselective behavior for chiral pesticides.The enantiomeric separation of three chiral pesticides,indoxacarb...Enantiomer separation is one of the most important prerequisites for the investigation of environmental enantioselective behavior for chiral pesticides.The enantiomeric separation of three chiral pesticides,indoxacarb,lambda-cyhalothrin,and simeconazole,were studied on cellulose tris-(3,5-dimethylphenyl-carbamate)-coated chiral stationary phase(CDMPC-CSP) using high-performance liquid chromatography under normal phase condition.The effects of chromatographic conditions,such as the mobile phase composition including the concentration and type of alcohol modifiers in hexane,flow rate and column temperature,on enantiomer separation were examined.The thermodynamical mechanism of enantioseparation and chiral recognition mechanism were discussed.Better separation were achieved using 20% n-propanol for indoxacarb,2% iso-butanol for lambda-cyhalothrin,and 20% iso-propanol for simeconazole as modifiers in hexane at 25℃ with the selectivity factor(a) of 1.69,1.82 and 1.70,respectively.The resolution factor(Rs) decreased as the flow rate increased from 0.4 to 1.1 ml·min-1.The retention factor(k') and selectivity factor for the enantiomers of analytes decreased as temperature increased.The lna-1/T plots for racemic chiral pesticides were linear in the range of 15-35℃ in hexane/iso-propanol and the chiral separation was controlled by enthalpy.Hydrogen bonding,π-π and dipole-dipole interactions between enantiomers and CDMPC-CSP play an important role in chiral identification,and the fitting of the asymmetric portion of solutes in a chiral cavity or channel of the CSP is also important.展开更多
文摘Ibuprofen is widely used as a non-steroidal anti-inflammatory drug and produced as racemic mixture. Its pharmacological activity resides only in S-(+)-enantiomer, and R-()-enantiomer is not only inactive but also has many side effects. Thus it is necessary to separate R-enantiomer from racemic ibuprofen. We studied optical separation of racemic Ibuprofen with chiral high performance liquid chromatography (HPLC). Out of three different chiral stationary phases, which were selected on the basis of structure and availability, two were found to be ef-fective. There was optimum eluent composition for each stationary phase for good resolution in optical separation. Resolution decreased with increase of eluent flow rate, but effect of injection volume on resolution was insignificant at high eluent flow rate.
基金Supported by China Postdoctoral Science Fund (20090461007)Postdoctoral Research Funding Special Plans of Hunan(2010RC4025)Graduate Innovation Research Project of Hunan (CX2010B295)
文摘Enantiomer separation is one of the most important prerequisites for the investigation of environmental enantioselective behavior for chiral pesticides.The enantiomeric separation of three chiral pesticides,indoxacarb,lambda-cyhalothrin,and simeconazole,were studied on cellulose tris-(3,5-dimethylphenyl-carbamate)-coated chiral stationary phase(CDMPC-CSP) using high-performance liquid chromatography under normal phase condition.The effects of chromatographic conditions,such as the mobile phase composition including the concentration and type of alcohol modifiers in hexane,flow rate and column temperature,on enantiomer separation were examined.The thermodynamical mechanism of enantioseparation and chiral recognition mechanism were discussed.Better separation were achieved using 20% n-propanol for indoxacarb,2% iso-butanol for lambda-cyhalothrin,and 20% iso-propanol for simeconazole as modifiers in hexane at 25℃ with the selectivity factor(a) of 1.69,1.82 and 1.70,respectively.The resolution factor(Rs) decreased as the flow rate increased from 0.4 to 1.1 ml·min-1.The retention factor(k') and selectivity factor for the enantiomers of analytes decreased as temperature increased.The lna-1/T plots for racemic chiral pesticides were linear in the range of 15-35℃ in hexane/iso-propanol and the chiral separation was controlled by enthalpy.Hydrogen bonding,π-π and dipole-dipole interactions between enantiomers and CDMPC-CSP play an important role in chiral identification,and the fitting of the asymmetric portion of solutes in a chiral cavity or channel of the CSP is also important.