A new error compensating five sample phase shifting algorithm which is insensitive to phase shift error is proposed to retrieve the phase distribution of a fringe pattern. It includes two steps. First, the linear ...A new error compensating five sample phase shifting algorithm which is insensitive to phase shift error is proposed to retrieve the phase distribution of a fringe pattern. It includes two steps. First, the linear phase shift error is estimated using four sample images. Then, the phase distribution is calculated with error corrected by using the phase shift error estimated in the first step. As the equations of error estimation and phase calculation are simple, this new algorithm is practical as well as effective. Computer simulations were carried out to verify the effectiveness of the algorithm. Results of two other well known error compensating algorithms are also presented, which show the new algorithm is the least sensitive to phase shift error.展开更多
According to the fact that the surface of liquid with low viscosity coefficient is a good reflection plane for a broadband light beam, liquid-level measurement in micrometer resolution is designed based on a fiber-opt...According to the fact that the surface of liquid with low viscosity coefficient is a good reflection plane for a broadband light beam, liquid-level measurement in micrometer resolution is designed based on a fiber-optic low coherence interferometer in Michelson configuration. The wave front of the reflected light beam is well enough to form an interferogram with a beam reflected from an optic mirror mounted on a stepping scanning-motor. The central peak of the interferogram is read as a measure of the liquid level. Experimental results show that this noncontact method can reach a resolution of ±1.25 μm in the measurement range of 86 mm.展开更多
Optical-phase-retardation elements are widely used in many fields.Accurate measurement of their phase retardation is crucial to the practical effect of the element's processing and application.The development and ...Optical-phase-retardation elements are widely used in many fields.Accurate measurement of their phase retardation is crucial to the practical effect of the element's processing and application.The development and present situation of the methods for optical phase retardation measurement are reviewed,with the wave plate,the most typical phase-retardation element,as an example.The latest research progress in this field is introduced;the principles and characteristics of individual measurement method are summarized and discussed.Three new methods based on laser frequency splitting or laser feedback are presented in detail,in which the laser is not only regarded as a light source but also plays a role of sensor.Moreover,no standard wave plates are needed and arbitrary phase retardation can be measured.Traceability,high precision and high repeatability are achieved as well.展开更多
In this paper,a binocular 3-D computer vision measurement system is used to measure the relative displacement for the greater and lesser tuberosities in the shoulder prosthesis.The basic principles of binocular optica...In this paper,a binocular 3-D computer vision measurement system is used to measure the relative displacement for the greater and lesser tuberosities in the shoulder prosthesis.The basic principles of binocular optical measurement are introduced in detail,and the loading apparatus is designed for external rotation and anteflexion of the shoulder prosthesis.Both the motion of external rotation and anteflexion of the shoulder are measured,and the corresponding displacement values for the greater and lesser tuberosities are extracted.These results will play an important role in evaluating the stability of humeral tuberosity in the shoulder prosthesis.展开更多
文摘A new error compensating five sample phase shifting algorithm which is insensitive to phase shift error is proposed to retrieve the phase distribution of a fringe pattern. It includes two steps. First, the linear phase shift error is estimated using four sample images. Then, the phase distribution is calculated with error corrected by using the phase shift error estimated in the first step. As the equations of error estimation and phase calculation are simple, this new algorithm is practical as well as effective. Computer simulations were carried out to verify the effectiveness of the algorithm. Results of two other well known error compensating algorithms are also presented, which show the new algorithm is the least sensitive to phase shift error.
基金Dalian Science and Technology Foundation and National Science Foundation(30470416)
文摘According to the fact that the surface of liquid with low viscosity coefficient is a good reflection plane for a broadband light beam, liquid-level measurement in micrometer resolution is designed based on a fiber-optic low coherence interferometer in Michelson configuration. The wave front of the reflected light beam is well enough to form an interferogram with a beam reflected from an optic mirror mounted on a stepping scanning-motor. The central peak of the interferogram is read as a measure of the liquid level. Experimental results show that this noncontact method can reach a resolution of ±1.25 μm in the measurement range of 86 mm.
基金supported by the Key Program of National Natural Science Foundation of China(Grant No.61036016)
文摘Optical-phase-retardation elements are widely used in many fields.Accurate measurement of their phase retardation is crucial to the practical effect of the element's processing and application.The development and present situation of the methods for optical phase retardation measurement are reviewed,with the wave plate,the most typical phase-retardation element,as an example.The latest research progress in this field is introduced;the principles and characteristics of individual measurement method are summarized and discussed.Three new methods based on laser frequency splitting or laser feedback are presented in detail,in which the laser is not only regarded as a light source but also plays a role of sensor.Moreover,no standard wave plates are needed and arbitrary phase retardation can be measured.Traceability,high precision and high repeatability are achieved as well.
基金supported by the National Natural Science Foundation of China(Grant Nos. 30470430,10802106)
文摘In this paper,a binocular 3-D computer vision measurement system is used to measure the relative displacement for the greater and lesser tuberosities in the shoulder prosthesis.The basic principles of binocular optical measurement are introduced in detail,and the loading apparatus is designed for external rotation and anteflexion of the shoulder prosthesis.Both the motion of external rotation and anteflexion of the shoulder are measured,and the corresponding displacement values for the greater and lesser tuberosities are extracted.These results will play an important role in evaluating the stability of humeral tuberosity in the shoulder prosthesis.