AIM:To evaluate the diagnosis of different differentiated gastric intraepithelial neoplasia (IN) by magnifica-tion endoscopy combined with narrow-band imaging (ME-NBI) and confocal laser endomicroscopy (CLE). METHODS:...AIM:To evaluate the diagnosis of different differentiated gastric intraepithelial neoplasia (IN) by magnifica-tion endoscopy combined with narrow-band imaging (ME-NBI) and confocal laser endomicroscopy (CLE). METHODS:Eligible patients with suspected gastric IN lesions previously diagnosed by endoscopy in secondary hospitals and scheduled for further diagnosis and tratment were recruited for this study. Excluded from the study were patients who had liver cirrhosis, impaired renal function, acute gastrointestinal (GI) bleeding, coagulopathy, esophageal varices, jaundice, and GI post-surgery. Also excluded were those who were pregnant, breastfeeding, were younger than 18 years old, or were unable to provide informed consent. All patients had all mucus and bile cleared from their stom-achs. They then received upper GI endoscopy. When a mucosal lesion is found during observation with whitelight imaging, the lesion is visualized using maximal magnification, employing gradual movement of the tip of the endoscope to bring the image into focus. Saved images are analyzed. Confocal images were evaluated by two endoscopists (Huang J and Li MY), who were familiar with CLE, blinded to the related information about the lesions, and asked to classify each lesion as either a low grade dysplasia (LGD) or high grade dysplasia (HGD) according to given criteria. The results were compared with the final histopathologic diagnosis. ME-NBI images were evaluated by two endoscopists (Lu ZS and Ling-Hu EQ) who were familiar with NBI, blinded to the related information about the lesions and CLE images, and were asked to classify each lesion as a LGD or HGD according to the "microvascular pattern and surface pattern" classification system. The results were compared with the final histopathologic diagnosis. RESULTS: The study included 32 pathology-proven low grade gastric IN and 26 pathology-proven high grade gastric IN that were detected with any of the modalities. CLE and ME-NBI enabled clear visualization of the vascular microsurface patterns and microvascular structures of the gastric mucosa. The accuracy of the CLE and the ME-NBI diagnosis was 88% (95% CI:78%-98%) and 81% (95% CI: 69%-93%), respectively. The kappa coefficient of agreement between the histopathology and the in vivo CLE imaging was 0.755; between the histopathology and the in vivo CLE imaging was 0.615. McNemar's test (binomial distribution used) indicated that the agreement was significant (P < 0.05). When patients were diagnosed by MENBI with CLE, the overall accuracy of the diagnosis was 86.21% (95% CI:73%-96%), and the kappa coefficient of agreement was 0.713, according to McNemar's test (P < 0.05). CONCLUSION:Higher diagnostic accuracy, sensitivityand specificity of CLE over ME-NBI indicate the feasibility of these two techniques for the efficacious diagnostic classification of gastric IN.展开更多
In this paper, we overview the principle of Orthogonal Frequency Division Multiplexing Passive Optical Network (OFDM-PON) systems, with a particular focus on upstream architectures capable of achieving 10Gbit/s colo...In this paper, we overview the principle of Orthogonal Frequency Division Multiplexing Passive Optical Network (OFDM-PON) systems, with a particular focus on upstream architectures capable of achieving 10Gbit/s colorless upstream transmission using Reflective Semiconductor Optical Amplifier (RSOA). We propose an architecture of RSOA based OFDM-PON which can achieve 10Gbit/s upstream transmission over a single wavelength. A novel Dynamic Subcarrier Assignment (DSA) algorithm is also proposed to support my architecture, namely Service based Polling in Pipeline (SPP) dynamic subcarrier algorithm. A simulation was conducted to study the performance of SPP algorithm. Compared with the traditional dynamic bandwidth allocation algorithms, service based polling meets the quality of in pipeline algorithm service requirements excellently, and adapts orthogonal frequency division multiplexing passive optical network better with higher bandwidth efficiency and lower algorithm complexity.展开更多
Abscisic acid (ABA) is an important plant hormone. It plays a key role in regulating plant responses to abiotic stress and in controlling seed germination, growth, and stomatal aperture. A rapid, sensitive analytical ...Abscisic acid (ABA) is an important plant hormone. It plays a key role in regulating plant responses to abiotic stress and in controlling seed germination, growth, and stomatal aperture. A rapid, sensitive analytical method for the ABA detection is urgently required for further investigation of ABA signaling. In this work, an immunomagnetic assay combined with CdSe/ZnS amplification of chemiluminescence has been developed for the detection of ABA. The result could be read out in 30 min at least, with the simplified procedure of immunomagnetic assay. Under the optimized condition, a linear range from 1 pM to 10 nM was obtained. An unexpected result induced by the dose hook effect was discussed. This method provided the high selectivity for ABA over other components that might be contained in real samples.展开更多
文摘AIM:To evaluate the diagnosis of different differentiated gastric intraepithelial neoplasia (IN) by magnifica-tion endoscopy combined with narrow-band imaging (ME-NBI) and confocal laser endomicroscopy (CLE). METHODS:Eligible patients with suspected gastric IN lesions previously diagnosed by endoscopy in secondary hospitals and scheduled for further diagnosis and tratment were recruited for this study. Excluded from the study were patients who had liver cirrhosis, impaired renal function, acute gastrointestinal (GI) bleeding, coagulopathy, esophageal varices, jaundice, and GI post-surgery. Also excluded were those who were pregnant, breastfeeding, were younger than 18 years old, or were unable to provide informed consent. All patients had all mucus and bile cleared from their stom-achs. They then received upper GI endoscopy. When a mucosal lesion is found during observation with whitelight imaging, the lesion is visualized using maximal magnification, employing gradual movement of the tip of the endoscope to bring the image into focus. Saved images are analyzed. Confocal images were evaluated by two endoscopists (Huang J and Li MY), who were familiar with CLE, blinded to the related information about the lesions, and asked to classify each lesion as either a low grade dysplasia (LGD) or high grade dysplasia (HGD) according to given criteria. The results were compared with the final histopathologic diagnosis. ME-NBI images were evaluated by two endoscopists (Lu ZS and Ling-Hu EQ) who were familiar with NBI, blinded to the related information about the lesions and CLE images, and were asked to classify each lesion as a LGD or HGD according to the "microvascular pattern and surface pattern" classification system. The results were compared with the final histopathologic diagnosis. RESULTS: The study included 32 pathology-proven low grade gastric IN and 26 pathology-proven high grade gastric IN that were detected with any of the modalities. CLE and ME-NBI enabled clear visualization of the vascular microsurface patterns and microvascular structures of the gastric mucosa. The accuracy of the CLE and the ME-NBI diagnosis was 88% (95% CI:78%-98%) and 81% (95% CI: 69%-93%), respectively. The kappa coefficient of agreement between the histopathology and the in vivo CLE imaging was 0.755; between the histopathology and the in vivo CLE imaging was 0.615. McNemar's test (binomial distribution used) indicated that the agreement was significant (P < 0.05). When patients were diagnosed by MENBI with CLE, the overall accuracy of the diagnosis was 86.21% (95% CI:73%-96%), and the kappa coefficient of agreement was 0.713, according to McNemar's test (P < 0.05). CONCLUSION:Higher diagnostic accuracy, sensitivityand specificity of CLE over ME-NBI indicate the feasibility of these two techniques for the efficacious diagnostic classification of gastric IN.
基金supported by NSFC Project No.61372119863 Program No.2011AA01A104Doctoral Scientific Fund Project of the Ministry of Education of China(No.20120005110010)
文摘In this paper, we overview the principle of Orthogonal Frequency Division Multiplexing Passive Optical Network (OFDM-PON) systems, with a particular focus on upstream architectures capable of achieving 10Gbit/s colorless upstream transmission using Reflective Semiconductor Optical Amplifier (RSOA). We propose an architecture of RSOA based OFDM-PON which can achieve 10Gbit/s upstream transmission over a single wavelength. A novel Dynamic Subcarrier Assignment (DSA) algorithm is also proposed to support my architecture, namely Service based Polling in Pipeline (SPP) dynamic subcarrier algorithm. A simulation was conducted to study the performance of SPP algorithm. Compared with the traditional dynamic bandwidth allocation algorithms, service based polling meets the quality of in pipeline algorithm service requirements excellently, and adapts orthogonal frequency division multiplexing passive optical network better with higher bandwidth efficiency and lower algorithm complexity.
基金supported by the National Natural Science Foundation of China (21075093 & 90717111)the Science Fund for Creative Research Groups of the National Natural Science Foundation of China (20921062)+1 种基金the National Key Scientific Program-Nanoscience and Nanotechnology (2011CB933600)the National Basic Research Program of China (2007CB714507)
文摘Abscisic acid (ABA) is an important plant hormone. It plays a key role in regulating plant responses to abiotic stress and in controlling seed germination, growth, and stomatal aperture. A rapid, sensitive analytical method for the ABA detection is urgently required for further investigation of ABA signaling. In this work, an immunomagnetic assay combined with CdSe/ZnS amplification of chemiluminescence has been developed for the detection of ABA. The result could be read out in 30 min at least, with the simplified procedure of immunomagnetic assay. Under the optimized condition, a linear range from 1 pM to 10 nM was obtained. An unexpected result induced by the dose hook effect was discussed. This method provided the high selectivity for ABA over other components that might be contained in real samples.