Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change tradi...Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change traditional manual way of shaft alignment and to make the measurement easier and more accurate. The system is comprised of two small measuring units (laser transmitter and detector) and a PDA (Personal Digital Assistant) with measurement software. The laser alignment system with dual PSDs was improved on a single PSD system, and yields higher measurement accuracy than the previous design, and has been successful for designing and implements actual shaft alignment. In the system, the range of offset measurement is ±4 mm, and the resolution is 1.5 μm, with accuracy being less than 2 μm.展开更多
An experimental investigation of effects of a kind of streamwise-grooved blade on the unsteady flow field at an exit of an axial-flow fan was performed. The flow field at 25% chord downstream from the trailing edge at...An experimental investigation of effects of a kind of streamwise-grooved blade on the unsteady flow field at an exit of an axial-flow fan was performed. The flow field at 25% chord downstream from the trailing edge at hub was measured using a fast-response five-hole pressure probe at different mass-flow conditions. The unsteady flow of the grooved blades was compared with that of the smooth blades. The measurement results indicate that: (1) the grooved blades restrain the velocity fluctuation and the pressure fluctuation by modulating the blade boundary layers, which contributes to the flow loss reduction in the hub region and in the rotor wake region at the design condition; (2) the stream-wise grooves play an important role in restraining the radial migration in the blade boundary layer and abating the tip flow mixing, which contributes to the flow loss reduction in the tip region at the design condition; (3) at the near stall condition, the grooved surface can not reduce the flow loss, even increase the loss nearby when the separation happens in the blade boundary layer.展开更多
基金Project (No. 60337030) partly supported by the National NaturalScience Foundation of China
文摘Shaft alignment is an important technique during installation and maintenance of a rotating machine. A high-precision laser alignment system has been designed with dual PSDs (Position Sensing Detector) to change traditional manual way of shaft alignment and to make the measurement easier and more accurate. The system is comprised of two small measuring units (laser transmitter and detector) and a PDA (Personal Digital Assistant) with measurement software. The laser alignment system with dual PSDs was improved on a single PSD system, and yields higher measurement accuracy than the previous design, and has been successful for designing and implements actual shaft alignment. In the system, the range of offset measurement is ±4 mm, and the resolution is 1.5 μm, with accuracy being less than 2 μm.
基金National Natural Science Foundation of China,Grant No.50376002the 111 Project,No.B07009
文摘An experimental investigation of effects of a kind of streamwise-grooved blade on the unsteady flow field at an exit of an axial-flow fan was performed. The flow field at 25% chord downstream from the trailing edge at hub was measured using a fast-response five-hole pressure probe at different mass-flow conditions. The unsteady flow of the grooved blades was compared with that of the smooth blades. The measurement results indicate that: (1) the grooved blades restrain the velocity fluctuation and the pressure fluctuation by modulating the blade boundary layers, which contributes to the flow loss reduction in the hub region and in the rotor wake region at the design condition; (2) the stream-wise grooves play an important role in restraining the radial migration in the blade boundary layer and abating the tip flow mixing, which contributes to the flow loss reduction in the tip region at the design condition; (3) at the near stall condition, the grooved surface can not reduce the flow loss, even increase the loss nearby when the separation happens in the blade boundary layer.