The fan-beam optical sensor is made up of many semiconductor lasers and detectors fixed around the wall alternately at a cross section of pneumatically conveying pipe. When the sensor works, a scanning light source em...The fan-beam optical sensor is made up of many semiconductor lasers and detectors fixed around the wall alternately at a cross section of pneumatically conveying pipe. When the sensor works, a scanning light source emits a 50° lamellar fan-beam through the gas-solid two phase flow, and the projection data resulting extinction effect of solid particles are detected at the same time. With the projection data, the flow rate mass can be calculated, and then the flow image can be reconstructed. In this paper, the design of the sensor including spatial arrangement of the structural parts, basic principle and measurement sensitivity distribution are introduced. The mathematical measurement model of solid mass flow rate is presented together with the testing results.展开更多
Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating t...Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating the current effective value is given. The cut - off characteristics of the breaker are classified. This system can provide a foundation for reasonably determining the breaker service period.展开更多
Landslides and debris flows are typical geo-hazards which occur in hilly or mountainous regions. Debris flows may result from landslides. Geotechnical instrumentation plays an important role in monitoring and warning ...Landslides and debris flows are typical geo-hazards which occur in hilly or mountainous regions. Debris flows may result from landslides. Geotechnical instrumentation plays an important role in monitoring and warning of landslides and resulted debris flows. Traditional technologies for monitoring landslides and debris flows have certain limitations. The new optical fiber sensors presented in this paper can overcome those limitations. This paper presents two new optical fiber sensor systems: one is the Fiber Bragg Grating (FBG)-based in-place inclinometer for monitoring landslides and the other is the FBG-based column-net system for monitoring debris flows. This paper presents the calibration results of FBG-based in-place inclinometers in laboratory. It is found that the calibration results are in good agreement with theoretical results. Both the FBG-based in-place inclinometers and the FBG-based column-net system have been installed at a site in Weijiagou valley, Beichuan County, Sichuan Province of China. Some preliminary results have been obtained and reported in the paper. The advantages of the FBG monitoring systems and their potential applications are also presented.展开更多
The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structu...The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper.展开更多
An observer-based fault diagnosis method and a fault tolerant control for open-switch fault and current sensor fault are proposed for interleaved flyback converters of a micro-inverter system. First, based on the topo...An observer-based fault diagnosis method and a fault tolerant control for open-switch fault and current sensor fault are proposed for interleaved flyback converters of a micro-inverter system. First, based on the topology of a grid-connected micro-inverter, a mathematical model of the flyback converters is established. Second, a state observer is applied to estimate the currents online and generate corresponding residuals. The fault is diagnosed by comparing the residuals with the thresholds. Finally, a fault-tolerant control that consists of a fault-tolerant topology for the faulty switch and a simple software redundancy control for the faulty current sensor, is proposed to achieve a fault-tolerant operation. The feasibility and effectiveness of the proposed method has been verified by simulation and experimental results.展开更多
A magneto-optical sensor, using a dual quadrature polarimetfic processing scheme, was evaluated for current metering and protection applications in high voltage lines. Sensor calibration and resolution were obtained i...A magneto-optical sensor, using a dual quadrature polarimetfic processing scheme, was evaluated for current metering and protection applications in high voltage lines. Sensor calibration and resolution were obtained in different operational conditions using illumination in the 1550-nm band. Results obtained indicated the feasibility of interrogating such sensor via the optical ground wire (OPGW) link installed in standard high power grids. The polarimetric bulk optical current sensor also was theoretically studied, and the effects of different sources of error considering practical deployment were evaluated. In particular, the interference from external magnetic fields in a tree-phase system was analyzed.展开更多
基金Project (No. 04009469) supported by the Natural Science Foundationof Guangdong, China
文摘The fan-beam optical sensor is made up of many semiconductor lasers and detectors fixed around the wall alternately at a cross section of pneumatically conveying pipe. When the sensor works, a scanning light source emits a 50° lamellar fan-beam through the gas-solid two phase flow, and the projection data resulting extinction effect of solid particles are detected at the same time. With the projection data, the flow rate mass can be calculated, and then the flow image can be reconstructed. In this paper, the design of the sensor including spatial arrangement of the structural parts, basic principle and measurement sensitivity distribution are introduced. The mathematical measurement model of solid mass flow rate is presented together with the testing results.
文摘Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating the current effective value is given. The cut - off characteristics of the breaker are classified. This system can provide a foundation for reasonably determining the breaker service period.
基金supported by research grants of The Hong Kong Polytechnic University (Grant Nos. G-YE54 and 1-BB7U)supported by the State Key Fundamental Research (973) program project (Grant No. 2008CB425802)supported by a project entitled "Analysis of Geological and Mechanics Reasons Causing Damage of Bridge Structures during Wenchuan Earthquake and Recommendations for Reconstruction" (A/C No. 85G0)
文摘Landslides and debris flows are typical geo-hazards which occur in hilly or mountainous regions. Debris flows may result from landslides. Geotechnical instrumentation plays an important role in monitoring and warning of landslides and resulted debris flows. Traditional technologies for monitoring landslides and debris flows have certain limitations. The new optical fiber sensors presented in this paper can overcome those limitations. This paper presents two new optical fiber sensor systems: one is the Fiber Bragg Grating (FBG)-based in-place inclinometer for monitoring landslides and the other is the FBG-based column-net system for monitoring debris flows. This paper presents the calibration results of FBG-based in-place inclinometers in laboratory. It is found that the calibration results are in good agreement with theoretical results. Both the FBG-based in-place inclinometers and the FBG-based column-net system have been installed at a site in Weijiagou valley, Beichuan County, Sichuan Province of China. Some preliminary results have been obtained and reported in the paper. The advantages of the FBG monitoring systems and their potential applications are also presented.
文摘The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper.
基金Project(2012AA051601)supported by the High-Tech Research and Development Program of China
文摘An observer-based fault diagnosis method and a fault tolerant control for open-switch fault and current sensor fault are proposed for interleaved flyback converters of a micro-inverter system. First, based on the topology of a grid-connected micro-inverter, a mathematical model of the flyback converters is established. Second, a state observer is applied to estimate the currents online and generate corresponding residuals. The fault is diagnosed by comparing the residuals with the thresholds. Finally, a fault-tolerant control that consists of a fault-tolerant topology for the faulty switch and a simple software redundancy control for the faulty current sensor, is proposed to achieve a fault-tolerant operation. The feasibility and effectiveness of the proposed method has been verified by simulation and experimental results.
文摘A magneto-optical sensor, using a dual quadrature polarimetfic processing scheme, was evaluated for current metering and protection applications in high voltage lines. Sensor calibration and resolution were obtained in different operational conditions using illumination in the 1550-nm band. Results obtained indicated the feasibility of interrogating such sensor via the optical ground wire (OPGW) link installed in standard high power grids. The polarimetric bulk optical current sensor also was theoretically studied, and the effects of different sources of error considering practical deployment were evaluated. In particular, the interference from external magnetic fields in a tree-phase system was analyzed.