期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
保证钴机定位器和光测距离指示器精度的重要性
1
作者 凌金城 《医学工程师》 1995年第2期19-19,共1页
钴60治疗机定时器和光测距离指示器的精度对临床治疗的影响及应采取的措施。
关键词 肿瘤 放射治疗机 钴机 定位器 光测距离 指示器
下载PDF
Laser diode drive method with narrow-width and high-peak current for multi-line LIDAR 被引量:2
2
作者 LI Xu DUAN Fa-jie +3 位作者 MA Ling WANG Xian-quan JIANG Jia-jia FU Xiao 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期246-253,共8页
Light detection and ranging (LIDAR) based on time of flight (TOF) method is widely used in many fields related to distance measurement. LIDAR generally uses laser diode (LD) to emit the pulsed laser with high peak pow... Light detection and ranging (LIDAR) based on time of flight (TOF) method is widely used in many fields related to distance measurement. LIDAR generally uses laser diode (LD) to emit the pulsed laser with high peak power and short duration to ensure a large distance measurement range and eye safety. To achieve this goal, we propose a pulsed LD drive method producing the drive current with high peak and narrow pulse width. We analyze the key issues and related theories of the drive current generation based on this method and design an LD driver. A model of drive current generation is established and the influence of operating frequency on drive current is discussed. The LD driver is simulated by software and verified by experiments. The working frequency of the driver changes from 20 kHz to 100 kHz and the charging voltage is set at 130 V. The current produced by this driver has a duration of 8.8 ns and a peak of about 35 A, and the peak output optical power of the LD exceeds 75 W. 展开更多
关键词 light detection and ranging(LIDAR) distance measurement laser diode (LD) driver pulsed current
下载PDF
Evaluation of an interferometric distance meter
3
作者 Osama Terra Hatem Hussein Mohamed Amer 《Journal of Measurement Science and Instrumentation》 CAS 2014年第3期73-78,共6页
This paper discussed the main parameters contributing to the measurement uncertainty of interferometric distance meter (IDM). A simple and robust set-up is used to measure distance of about 12 cm with an expanded un... This paper discussed the main parameters contributing to the measurement uncertainty of interferometric distance meter (IDM). A simple and robust set-up is used to measure distance of about 12 cm with an expanded uncertainty ( k = 2) of ±16.4 μm. The measurement uncertainty is found to be limited by the wavelength measurement accuracy. This set-up can be used to measure distances up to 56 m. It also enables easy determination of the point of equal path difference between the measuring and the reference arms. LabVIEW program is used for counting of the fringes and applying fast Fourier transfor- mation (FFT) to perform frequency selective filtration to the noise. Although the reported uncertainty does not represent the state-of-art uncertainty reached for similar distance, the measurement provides traceable measurement to the unit of length, the meter. 展开更多
关键词 distance measurement length measurement optical interferometer
下载PDF
Comparison of Absolute Distance Measurement by Different Types of Dual Mode-Locked Fiber Lasers
4
作者 Tze-An Liu Yi-Chen Chuang +2 位作者 Hau-Wei Lee Po-Er Hsu Jin-Long Peng 《Journal of Mechanics Engineering and Automation》 2015年第12期676-680,共5页
Two types of the dual mode-locked fiber lasers for asynchronous absolute distance measurement are investigated, The lasers are linear and ring cavity with repetition rate of 70 MHz and 100 MHz, respectively. The group... Two types of the dual mode-locked fiber lasers for asynchronous absolute distance measurement are investigated, The lasers are linear and ring cavity with repetition rate of 70 MHz and 100 MHz, respectively. The group velocity dispersion is not compensated in the first type of the lasers, while the others are fully done. The timing jitter with the Allan deviation below averaging time of 0.2 s during the distance measurement for around 1 m of both types of lasers were 2.5 ps with 600 nm and 1.6 ps with 200 nm. We concluded that the phase noise resulted from the intra-cavity dispersion is the main contribution for the uncertainty of the ranging in these two types of the lasers. 展开更多
关键词 MODE-LOCKED fiber laser DISTANCE timing jitter.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部