The simple approach to acquire the fltaxescenee spectra of vitamin bl, b2 and t6 is proposed by direct ilhanination on solid powder sample. The experimentally acquired fluorescence spectra are in accordance with the p...The simple approach to acquire the fltaxescenee spectra of vitamin bl, b2 and t6 is proposed by direct ilhanination on solid powder sample. The experimentally acquired fluorescence spectra are in accordance with the previous measurements on soluble samples. The fluorescence spectra for a mixture of vitamins bl, b2 and b6 with different concentrations have been investigated, and the fluorescence mechanism is explained on the basis of moleoalar struchture Possible reasons of the blue-shift of the fluorescence peak and enhancement of the peak power are explained as well. The advantages of solid powder method is analyzed and discussed.展开更多
CuO was synthesized by thermal decomposition of Cu(NO3)2·3H2O at various temperatures and characterized by powder X-ray diffractometry(XRD) as well as scanning electron microscopy(SEM).The effects of calcination ...CuO was synthesized by thermal decomposition of Cu(NO3)2·3H2O at various temperatures and characterized by powder X-ray diffractometry(XRD) as well as scanning electron microscopy(SEM).The effects of calcination temperature,category of sacrificial reagent,initial sacrificial reagent concentration,and Ag loading content on the photocatalytic activity of the as-obtained CuO sample were investigated.The results show that the as-obtained CuO exhibits high activity for photocatalysis of H2 evolution reaction(HER) in oxalic acid solution under simulated sunlight irradiation.The highest photocatalytic activity of the as-obtained CuO was achieved at the calcination temperature of 1000℃,and oxalic acid was used as the sacrificial reagent with the concentration 0.05 mol/L.H2 evolution rate is as high as 2.98 mmol/(h·g) with 2%(mass fraction) loaded Ag.The possible photocatalytic reaction mechanism on the CuO photocatalyst for HER in oxalic acid solution was also discussed.展开更多
By analyzing the deficiencies of the method, a measurement system with the technologies of photoelectricity, laser and digital image processing to synthetically measure these two parameters has been developed. A tradi...By analyzing the deficiencies of the method, a measurement system with the technologies of photoelectricity, laser and digital image processing to synthetically measure these two parameters has been developed. A traditional method to measure the swaying quantity and multi-barrel parallelism of rocket launcher is introduced. Meanwhile, the principle, executive plan and the accuracy analysis are also presented. The photoelectric measurement system has been applied in the swaying quantity and multi-barrel parallelism measurement for Φ122 mm and Φ302 mm rocket launcher. The metrical errors are both 16^th.展开更多
We aimed to study the appropriate posture of peripherally inserted central catheter (PICC) patients, to reduce the incidence of internal jugular vein heterotopia. Methods: From 2009 to 2013, a total of 290 cases wi...We aimed to study the appropriate posture of peripherally inserted central catheter (PICC) patients, to reduce the incidence of internal jugular vein heterotopia. Methods: From 2009 to 2013, a total of 290 cases with PICC were enrolled in our study. They were divided into two groups. The patients in control group took regular position, which mean pros- tration, upper limb of tube side was abduction 90°, head moved to puncture side in order to block the internal jugular vein. On the basis of conventional body position putting, posture of patients in observation group was improved, the head remain neutral, and had 180° angle with trunk longitudinal axis, not favor any side. After ensuring the upper limb abduction, had 90° angle with the trunk, then catheter was inserted slowly. The jugular venous catheter heterotopia rate was judged by X.ray results. Results: The jugular venous catheter heterotopia rate of control group and observation was 12.8% and 0.68%, respectively. The difference between two groups was statistically significant (P 〈 0.01). Conclusion: The body posture improvement can prevent discomfort of patients and reduce the jugular venous catheter heterotopia rate of PICC.展开更多
基金supported by the Tianjin Natural Science Foundation(No.06YFJZJC00300)the Natural Science Foundation of China(Nos.10674075,10774077,10674074,50802044 and 60736039)
文摘The simple approach to acquire the fltaxescenee spectra of vitamin bl, b2 and t6 is proposed by direct ilhanination on solid powder sample. The experimentally acquired fluorescence spectra are in accordance with the previous measurements on soluble samples. The fluorescence spectra for a mixture of vitamins bl, b2 and b6 with different concentrations have been investigated, and the fluorescence mechanism is explained on the basis of moleoalar struchture Possible reasons of the blue-shift of the fluorescence peak and enhancement of the peak power are explained as well. The advantages of solid powder method is analyzed and discussed.
基金Project(20876039) supported by the National Natural Science Foundation of ChinaProject(09JJ3023) supported by Natural Science Foundation of Hunan Province, China
文摘CuO was synthesized by thermal decomposition of Cu(NO3)2·3H2O at various temperatures and characterized by powder X-ray diffractometry(XRD) as well as scanning electron microscopy(SEM).The effects of calcination temperature,category of sacrificial reagent,initial sacrificial reagent concentration,and Ag loading content on the photocatalytic activity of the as-obtained CuO sample were investigated.The results show that the as-obtained CuO exhibits high activity for photocatalysis of H2 evolution reaction(HER) in oxalic acid solution under simulated sunlight irradiation.The highest photocatalytic activity of the as-obtained CuO was achieved at the calcination temperature of 1000℃,and oxalic acid was used as the sacrificial reagent with the concentration 0.05 mol/L.H2 evolution rate is as high as 2.98 mmol/(h·g) with 2%(mass fraction) loaded Ag.The possible photocatalytic reaction mechanism on the CuO photocatalyst for HER in oxalic acid solution was also discussed.
文摘By analyzing the deficiencies of the method, a measurement system with the technologies of photoelectricity, laser and digital image processing to synthetically measure these two parameters has been developed. A traditional method to measure the swaying quantity and multi-barrel parallelism of rocket launcher is introduced. Meanwhile, the principle, executive plan and the accuracy analysis are also presented. The photoelectric measurement system has been applied in the swaying quantity and multi-barrel parallelism measurement for Φ122 mm and Φ302 mm rocket launcher. The metrical errors are both 16^th.
文摘We aimed to study the appropriate posture of peripherally inserted central catheter (PICC) patients, to reduce the incidence of internal jugular vein heterotopia. Methods: From 2009 to 2013, a total of 290 cases with PICC were enrolled in our study. They were divided into two groups. The patients in control group took regular position, which mean pros- tration, upper limb of tube side was abduction 90°, head moved to puncture side in order to block the internal jugular vein. On the basis of conventional body position putting, posture of patients in observation group was improved, the head remain neutral, and had 180° angle with trunk longitudinal axis, not favor any side. After ensuring the upper limb abduction, had 90° angle with the trunk, then catheter was inserted slowly. The jugular venous catheter heterotopia rate was judged by X.ray results. Results: The jugular venous catheter heterotopia rate of control group and observation was 12.8% and 0.68%, respectively. The difference between two groups was statistically significant (P 〈 0.01). Conclusion: The body posture improvement can prevent discomfort of patients and reduce the jugular venous catheter heterotopia rate of PICC.