In order to build method for measuring of elements in honey, the contents of Ba, Cu, Pb, Cd, As, Hg, Cr, Mn, Se had been determined by microwave diges- tion (MWD) and actively coupled plasma atomic emission spectrom...In order to build method for measuring of elements in honey, the contents of Ba, Cu, Pb, Cd, As, Hg, Cr, Mn, Se had been determined by microwave diges- tion (MWD) and actively coupled plasma atomic emission spectrometry (ICP-AES). The results show that, the range of heavy metal elements were in the range of 0- 10.0 mg/L, with good linear relationship. In addition, all correlation coefficients kept higher than 0.999, and the recovery rate of ample added with standard solution was in 94.1%-110%. By comparison with the result of chemical experiment, the method was quickly accessible and convenient, widely used in the measurement of elements in honey, with satisfactory results.展开更多
In order to develop a method for measuring of elements in Sipunculus nudus, the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were determined by actively coupled plasma atomic emission spectrometry (MWD) and microwa...In order to develop a method for measuring of elements in Sipunculus nudus, the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were determined by actively coupled plasma atomic emission spectrometry (MWD) and microwave digestion (ICP-AES). The results showed that correlation coefficients al kept higher than 0.999 and the recovery rates of sample added standard solutions were in 98%-114%. The results indicated that the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were 17.119, 3.781, 0.695, 7.351, 1997.982, 0.620, 0.144, 4.249 mg/kg respectively. The contents of Mn exceeded national limit by hundredfold, Cd sevenfold, Pd fourfold, Cd three-and-a-half-fold, and As onefold. Sipunculs nudus became seriously pol uted. Therefore, it is necessary to formulate robust policies to fol ow closely and pay close attention to coastal areas pol ution around Dongfang City.展开更多
Molecular frame photoemission is a very sensitive probe of the photoionization (PI) dynamics of molecules. This paper reports a comparative study of non-resonant and resonant photoionization of D2 induced by VUV cir...Molecular frame photoemission is a very sensitive probe of the photoionization (PI) dynamics of molecules. This paper reports a comparative study of non-resonant and resonant photoionization of D2 induced by VUV circularly polarized synchrotron radiation at SOLEIL at the level of the molecular frame photoelectron angular distributions (MFPADs). We use the vector correlation method which combines imaging and time-of-flight resolved electron-ion coincidence techniques, and a generalized formalism for the expression of the Ⅰ(χ, θe, Фe) MFPADs, where χ is the orientation of the molecular axis with respect to the light quantization axis and (θe, Фe) the electron emission direction in the molecular frame. Selected MFPADs for a molecule aligned parallel or perpendicular to linearly polarized light, or perpendicular to the propagation axis of circularly polarized light, are presented for dissociative photoionization (DPI) of D2 at two photon excitation energies, hv=19 eV, where direct PI is the only channel opened, and hv=32.5 eV, i.e. in the region involving resonant excitation of Q1 and Q2 doubly excited state series. We discuss in particular the properties of the circular dichroism characterizing photoemission in the molecular frame for direct and resonant PI. In the latter case, a remarkable behavior is observed which may be attributed to the interference occurring between undistinguishable autoionization decay channels.展开更多
The analysis of sucrose esters with long acyl chain by improved high performance liquid chromatographic method with evaporative light scattering detection (HPLC-ELSD) and electrospray ionization mass spectrum (ESI...The analysis of sucrose esters with long acyl chain by improved high performance liquid chromatographic method with evaporative light scattering detection (HPLC-ELSD) and electrospray ionization mass spectrum (ESI-MS) is investigated. The improved HPLC-ELSD method for the separation and quantitation of commercial and synthesized sucrose esters is described. Samples are analyzed by means of a reversed-phase (RP) HPLC using a Hypersil C8 column (250 mm× 4.6 mm, 5 μm particle size) with methanol-tetrahydrofuran (vo)ume ratio of 90 : 10) and water under gradientcondition as the mobile phase, in which the flow rate is 1.0 ml·min^-1 and the column temperature is set at 40℃. This procedure provides a complete separation and determination ot monoester, diester, triester and higher esters with different acyl chain lengths in each fraction by a single run, in combination with the ESI-MS technology. With this method, it is possible to determine the approximate compositions of monoto polyesters in one analysis and quantitate pure positional isomers precisely using an external standard method. It is found that the method of ESI-MS coupling with HPLC system for the analysis of sucrose esters is straight forward, rapid and inexpensive, and can be readily applied in synthesis, purification and structure studies.展开更多
We have developed a compact photoelectron imaging facility, including an anion source with dissociative photoelectron attachment to molecules, a linear time-of-flight mass spec-trometry (TOFMS), and an orthogonal hi...We have developed a compact photoelectron imaging facility, including an anion source with dissociative photoelectron attachment to molecules, a linear time-of-flight mass spec-trometry (TOFMS), and an orthogonal high-resolution threshold photoelectron velocity map imaging spectrometer (VMI). Intense and cold cluster anions were prepared in photoelectron- attachment processes upon pulsed UV laser ablation of metal target. Combining this anion source with TOFMS-VMI, the achieved mass resolution is about 200, and the electron ki- netic energy resolution is better than 3%, i.e., 30 meV for 1 eV electrons. More importantly, low-energy photoelectron imaging spectra for CH3S- and S2- at 611.46 nm are obtained. In both cases, the refined electron affinities are determined to be 1.86264-0.0020 eV for CH3S and 1.67444-0.0035 eV for S2, respectively. Preliminary results suggest that the apparatus is a powerful tool for estimating precise electron affinities values from threshold photoelectron imaging spectroscopy.展开更多
文摘In order to build method for measuring of elements in honey, the contents of Ba, Cu, Pb, Cd, As, Hg, Cr, Mn, Se had been determined by microwave diges- tion (MWD) and actively coupled plasma atomic emission spectrometry (ICP-AES). The results show that, the range of heavy metal elements were in the range of 0- 10.0 mg/L, with good linear relationship. In addition, all correlation coefficients kept higher than 0.999, and the recovery rate of ample added with standard solution was in 94.1%-110%. By comparison with the result of chemical experiment, the method was quickly accessible and convenient, widely used in the measurement of elements in honey, with satisfactory results.
文摘In order to develop a method for measuring of elements in Sipunculus nudus, the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were determined by actively coupled plasma atomic emission spectrometry (MWD) and microwave digestion (ICP-AES). The results showed that correlation coefficients al kept higher than 0.999 and the recovery rates of sample added standard solutions were in 98%-114%. The results indicated that the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were 17.119, 3.781, 0.695, 7.351, 1997.982, 0.620, 0.144, 4.249 mg/kg respectively. The contents of Mn exceeded national limit by hundredfold, Cd sevenfold, Pd fourfold, Cd three-and-a-half-fold, and As onefold. Sipunculs nudus became seriously pol uted. Therefore, it is necessary to formulate robust policies to fol ow closely and pay close attention to coastal areas pol ution around Dongfang City.
文摘Molecular frame photoemission is a very sensitive probe of the photoionization (PI) dynamics of molecules. This paper reports a comparative study of non-resonant and resonant photoionization of D2 induced by VUV circularly polarized synchrotron radiation at SOLEIL at the level of the molecular frame photoelectron angular distributions (MFPADs). We use the vector correlation method which combines imaging and time-of-flight resolved electron-ion coincidence techniques, and a generalized formalism for the expression of the Ⅰ(χ, θe, Фe) MFPADs, where χ is the orientation of the molecular axis with respect to the light quantization axis and (θe, Фe) the electron emission direction in the molecular frame. Selected MFPADs for a molecule aligned parallel or perpendicular to linearly polarized light, or perpendicular to the propagation axis of circularly polarized light, are presented for dissociative photoionization (DPI) of D2 at two photon excitation energies, hv=19 eV, where direct PI is the only channel opened, and hv=32.5 eV, i.e. in the region involving resonant excitation of Q1 and Q2 doubly excited state series. We discuss in particular the properties of the circular dichroism characterizing photoemission in the molecular frame for direct and resonant PI. In the latter case, a remarkable behavior is observed which may be attributed to the interference occurring between undistinguishable autoionization decay channels.
基金Supported by the National Natural Science Foundation of China (20906052), the Science Foundation of Nantong City Municipality (K2007011, K2008023), the Science Foundation of Nantong University (08R08) and the University Science Research Project of Jiangsu Province (09KJB530008).
文摘The analysis of sucrose esters with long acyl chain by improved high performance liquid chromatographic method with evaporative light scattering detection (HPLC-ELSD) and electrospray ionization mass spectrum (ESI-MS) is investigated. The improved HPLC-ELSD method for the separation and quantitation of commercial and synthesized sucrose esters is described. Samples are analyzed by means of a reversed-phase (RP) HPLC using a Hypersil C8 column (250 mm× 4.6 mm, 5 μm particle size) with methanol-tetrahydrofuran (vo)ume ratio of 90 : 10) and water under gradientcondition as the mobile phase, in which the flow rate is 1.0 ml·min^-1 and the column temperature is set at 40℃. This procedure provides a complete separation and determination ot monoester, diester, triester and higher esters with different acyl chain lengths in each fraction by a single run, in combination with the ESI-MS technology. With this method, it is possible to determine the approximate compositions of monoto polyesters in one analysis and quantitate pure positional isomers precisely using an external standard method. It is found that the method of ESI-MS coupling with HPLC system for the analysis of sucrose esters is straight forward, rapid and inexpensive, and can be readily applied in synthesis, purification and structure studies.
文摘We have developed a compact photoelectron imaging facility, including an anion source with dissociative photoelectron attachment to molecules, a linear time-of-flight mass spec-trometry (TOFMS), and an orthogonal high-resolution threshold photoelectron velocity map imaging spectrometer (VMI). Intense and cold cluster anions were prepared in photoelectron- attachment processes upon pulsed UV laser ablation of metal target. Combining this anion source with TOFMS-VMI, the achieved mass resolution is about 200, and the electron ki- netic energy resolution is better than 3%, i.e., 30 meV for 1 eV electrons. More importantly, low-energy photoelectron imaging spectra for CH3S- and S2- at 611.46 nm are obtained. In both cases, the refined electron affinities are determined to be 1.86264-0.0020 eV for CH3S and 1.67444-0.0035 eV for S2, respectively. Preliminary results suggest that the apparatus is a powerful tool for estimating precise electron affinities values from threshold photoelectron imaging spectroscopy.