Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating t...Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating the current effective value is given. The cut - off characteristics of the breaker are classified. This system can provide a foundation for reasonably determining the breaker service period.展开更多
The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structu...The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper.展开更多
文摘Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating the current effective value is given. The cut - off characteristics of the breaker are classified. This system can provide a foundation for reasonably determining the breaker service period.
文摘The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper.