The performance of the photodetector is significantly impacted by the inherent surface faults in GaAs nanowires(NWs).We combined three-dimensional(3D)gallium arsenide nanowires with zero-dimensional(0D)WS_(2) quantum ...The performance of the photodetector is significantly impacted by the inherent surface faults in GaAs nanowires(NWs).We combined three-dimensional(3D)gallium arsenide nanowires with zero-dimensional(0D)WS_(2) quantum dot(QDs)materials in a simple and convenient way to form a heterogeneous structure.Various performance enhancements have been realized through the formation of typeⅡenergy bands in heterostructures,opening up new research directions for the future development of photodetector devices.This work successfully fabricated a high-sensitivity photodetector based on WS_(2)QDs/GaAs NWs heterostructure.Under 660 nm laser excitation,the photodetector exhibits a responsivity of 368.07 A/W,a detectivity of 2.7×10^(12)Jones,an external quantum efficiency of 6.47×10^(2)%,a low-noise equivalent power of 2.27×10^(-17)W·Hz^(-1/2),a response time of 0.3 s,and a recovery time of 2.12 s.This study provides a new solution for the preparation of high-performance GaAs detectors and promotes the development of optoelectronic devices for GaAs NWs.展开更多
A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity er...A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.展开更多
A new vision coordinate measuring system--single camera 3 D coordinate measuring system based on optical probe imaging is presented. A new idea in vision coordinate measurement is proposed. A linear model is deduced w...A new vision coordinate measuring system--single camera 3 D coordinate measuring system based on optical probe imaging is presented. A new idea in vision coordinate measurement is proposed. A linear model is deduced which can distinguish six freedom degrees of optical probe to realize coordinate measurement of the object surface. The effects of some factors on the resolution of the system are analyzed. The simulating experiments have shown that the system model is available.展开更多
In order to diagnose the laser-produced plasmas, a focusing curved crystal spectrometer has been developed for measuring the X-ray lines radiated from a laser-produced plasmas. The design is based on the fact that the...In order to diagnose the laser-produced plasmas, a focusing curved crystal spectrometer has been developed for measuring the X-ray lines radiated from a laser-produced plasmas. The design is based on the fact that the ray emitted from a source located at one focus of an ellipse will converge on the other focus by the reflection of the elliptical surface. The focal length and the eccentricity of the ellipse are 1350 mm and 0.9586, respectively. The spectrometer can be used to measure the X- ray lines in the wavelength range of 0.2-0.37 nm, and a LiF crystal (200) (2d = 0.4027 nm) is used as dispersive element covering Bragg angle from 30° to 67.5°. The spectrometer was tested on Shengnang- Ⅱ which can deliver laser energy of 60-80 J/pulse and the laser wavelength is 0.35 μm. Photographs of spectra including the 1 s2p ^1P1-1s^2 ^1S0 resonance line(w), the 1s2p ^3P2-1s^2 1S0 magnetic quadrupole line(x), the 1s2p ^3P1-1 s^2 ^1S0 intercombination lines(y), the 1 s2p ^3S^1-1 s^2 ^1S0 forbidden line(z) in helium-like Ti Ⅹ Ⅺ and the 1 s2s2p ^2P3/2-1 s622s ^2S1/2 line(q) in lithium-like Ti Ⅹ Ⅹhave been recorded with a X-ray CCD camera. The experimental result shows that the wavelength resolution(λ/△ 2) is above 1000 and the elliptical crystal spectrometer is suitable for X-ray spectroscopy.展开更多
A self-developed laser image measurement system was established to study the behavior of bubble for- mation at a single orifice in non-Newtonian polyacrylamide(PAAm)solutions.Images of bubbles were captured by a CCD c...A self-developed laser image measurement system was established to study the behavior of bubble for- mation at a single orifice in non-Newtonian polyacrylamide(PAAm)solutions.Images of bubbles were captured by a CCD camera and volumes of bubbles were digitally analyzed online.The effects of rheological property of PAAm solution,orifice,reservoir,and gas flowrate on bubble formation were studied experimentally.It is found that the volume of bubble increases with the concentration of PAAm solution,the diameter of the orifice,and the gas flowrate,respectively,whereas little effect of reservoir is observed in experiments.展开更多
Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measu...Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measurement is presented in this paper. In order to eliminate the noise, the ratio of the fundamental and second-harmonic signals is used. The mathematical model of gas concentration harmonic measurement is built up.The detection result of methane concentration is also shown. Experiments have proved a sensitivity of 28×10-6.展开更多
We propose two schemes for preparing four-photon cluster state through cross-Kerr nonlinearity. Two coherent fields interact when they enter a nonlinear Kerr medium. If the interaction time is chosen appropriately in ...We propose two schemes for preparing four-photon cluster state through cross-Kerr nonlinearity. Two coherent fields interact when they enter a nonlinear Kerr medium. If the interaction time is chosen appropriately in each Kerr medium, four-photon cluster state can be generated based on the results of two homodyne detectors in the first scheme. These schemes only use Kerr medium and homodyne measurements on coherent light fields, which can be effciently made in quantum optical laboratories. In addition, weak cross-Kerr nonlinearity is sufficient. All of the properties make these schemes feasible in experiments.展开更多
Conventional multispectral space for color representation is modified by algorithm of cluster analysis and principal component analysis. Results show that the newer modified multispectral space not only keeping the st...Conventional multispectral space for color representation is modified by algorithm of cluster analysis and principal component analysis. Results show that the newer modified multispectral space not only keeping the structure of the original space but eliminating zero crosses as well its accuracy of color representation is higher than the conventional.展开更多
The measurement principle and analysis method of natural gamma-ray spectra using Nal(T1) scintillation spectrometer are briefly described first, thed block diagrams of the HD-8004 Nal(T1) gamma-ray spectrometer. Fina...The measurement principle and analysis method of natural gamma-ray spectra using Nal(T1) scintillation spectrometer are briefly described first, thed block diagrams of the HD-8004 Nal(T1) gamma-ray spectrometer. Finally, sample measurements are listed and discussed. The results are quite promising. Based on the analysis of these measurements, measures to improve the accuracy of spectrum measurement are proposed. It is well hoped that these measures call contribute to the development and application of gamma-ray spectrum measurement.展开更多
In this paper, we present a probabilistic teleportation scheme for unknown bipartite entangled state. By using linear optical elements, we convert the Bell-state measurement into separated single-qubit measurements.
A precise two-degree-of-freedom measuring system (2DMS) is developed based on single-mode optical fiber, LD, cube corner retroreflector and four-quadrant photodetector (4-Q), and the simultaneous on-line measurement o...A precise two-degree-of-freedom measuring system (2DMS) is developed based on single-mode optical fiber, LD, cube corner retroreflector and four-quadrant photodetector (4-Q), and the simultaneous on-line measurement of lateral and vertical direction straightness errors of the linear stage is carried out. The moving part is wireless, which eliminates any errors introduced by pushing and pulling the wires. The sensitivity of the straightness error measurement can be improved by a factor of 2 with the cube corner retroreflector. This fiber-based optically aligned beam is used to establish a reference line for the straightness measurement of any mechanical system. 4-Q detector is used to receive the laser beam. A chip microcomputer is developed to conduct all data acquisition and signal processing. The beam drift influence can be removed in the greatest extent from the system. The experiments on the measurement system stability, repeatability and its comparison with the HP5528 double-frequency laser interferometer are carried out.展开更多
In this letter, we propose a scheme of a special quantum optical Fredkin gate assisted by optical manip- ulations and postselection from the coincidence measurements, and then modify it with cross-Kerr nonlinearities ...In this letter, we propose a scheme of a special quantum optical Fredkin gate assisted by optical manip- ulations and postselection from the coincidence measurements, and then modify it with cross-Kerr nonlinearities to be suitable for the realization of all possible positive operator-valued measurements of bipartite polarization states. This scheme is feasible in the lab with the current experimental technology.展开更多
A beam stabilization algorithm was proposed for low cost satcom-on-the-move (SOTM) to stabilize the vehicle-mounted antenna beam. The proposed algorithm utilizes the nonlinear observel to estimate the vehicle's att...A beam stabilization algorithm was proposed for low cost satcom-on-the-move (SOTM) to stabilize the vehicle-mounted antenna beam. The proposed algorithm utilizes the nonlinear observel to estimate the vehicle's attitude information based on inertial measurement unit. Then the estimated angles and angular velocities are used to stabilize the antenna beam. Experiment results show tha| the proposed algorithm can stabilize the antenna beam when the tracking information is available, indicating that it is competent to the SOTM system.展开更多
The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental s...The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental system with the method of optical heterodyne, using the refraction light beam from a prism, and made the experiment. The experimental results are in accordance with the theoretical calculation. It is very useful in some particular case, such as in Negative- Index Materials(NIM), to verify the Doppler Effect with this method.展开更多
The objective of this work is to assess the radiation hazards associated gamma rays from building materials. Natural gamma rays activities of natural radionuclide represented mainly by three natural radioactive series...The objective of this work is to assess the radiation hazards associated gamma rays from building materials. Natural gamma rays activities of natural radionuclide represented mainly by three natural radioactive series ^238U, ^235U and ^232Th, and the primordial ^40K in the samples of building materials which consist of bricks, ceramics, marble and gypsum from different areas of eastern Algeria are measured using gamma ray spectrometry. The values of the activities of these radionuclides do not clearly reflect the radiation hazard associated with these materials. Therefore, the radium equivalent (Raeq) concentration is defined taking into account the effectiveness of these isotopes in creating the radiation hazard. Radium equivalent activities, external and internal hazard indices (Hex and Hin) are calculated from the activities of ^226Ra, ^232Th and ^40K for suitability of the materials.展开更多
The authors synthesized very pure dimer phase of coroneae by simple heat-treatment and subsequent sublimation purification. It was confirmed by laser desorption/ionization mass spectroscopy measurements that pure dime...The authors synthesized very pure dimer phase of coroneae by simple heat-treatment and subsequent sublimation purification. It was confirmed by laser desorption/ionization mass spectroscopy measurements that pure dimer phase of coronenes can be obtained by controlling the fusing and sublimation temperatures. The crystal structure of the dimer phase was analyzed by synchrotron XRD (X-ray diffraction) experiments. It was also found that very bright red light is emitted by irradiating ultra violet light (λ = 350 nm) to the dimer phase. The external and internal quantum yields were determined to be 5.56% and 6.95%, respectively.展开更多
文摘The performance of the photodetector is significantly impacted by the inherent surface faults in GaAs nanowires(NWs).We combined three-dimensional(3D)gallium arsenide nanowires with zero-dimensional(0D)WS_(2) quantum dot(QDs)materials in a simple and convenient way to form a heterogeneous structure.Various performance enhancements have been realized through the formation of typeⅡenergy bands in heterostructures,opening up new research directions for the future development of photodetector devices.This work successfully fabricated a high-sensitivity photodetector based on WS_(2)QDs/GaAs NWs heterostructure.Under 660 nm laser excitation,the photodetector exhibits a responsivity of 368.07 A/W,a detectivity of 2.7×10^(12)Jones,an external quantum efficiency of 6.47×10^(2)%,a low-noise equivalent power of 2.27×10^(-17)W·Hz^(-1/2),a response time of 0.3 s,and a recovery time of 2.12 s.This study provides a new solution for the preparation of high-performance GaAs detectors and promotes the development of optoelectronic devices for GaAs NWs.
文摘A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.
文摘A new vision coordinate measuring system--single camera 3 D coordinate measuring system based on optical probe imaging is presented. A new idea in vision coordinate measurement is proposed. A linear model is deduced which can distinguish six freedom degrees of optical probe to realize coordinate measurement of the object surface. The effects of some factors on the resolution of the system are analyzed. The simulating experiments have shown that the system model is available.
基金the National Natural Science Foundation of China(Grant No. 10576041)
文摘In order to diagnose the laser-produced plasmas, a focusing curved crystal spectrometer has been developed for measuring the X-ray lines radiated from a laser-produced plasmas. The design is based on the fact that the ray emitted from a source located at one focus of an ellipse will converge on the other focus by the reflection of the elliptical surface. The focal length and the eccentricity of the ellipse are 1350 mm and 0.9586, respectively. The spectrometer can be used to measure the X- ray lines in the wavelength range of 0.2-0.37 nm, and a LiF crystal (200) (2d = 0.4027 nm) is used as dispersive element covering Bragg angle from 30° to 67.5°. The spectrometer was tested on Shengnang- Ⅱ which can deliver laser energy of 60-80 J/pulse and the laser wavelength is 0.35 μm. Photographs of spectra including the 1 s2p ^1P1-1s^2 ^1S0 resonance line(w), the 1s2p ^3P2-1s^2 1S0 magnetic quadrupole line(x), the 1s2p ^3P1-1 s^2 ^1S0 intercombination lines(y), the 1 s2p ^3S^1-1 s^2 ^1S0 forbidden line(z) in helium-like Ti Ⅹ Ⅺ and the 1 s2s2p ^2P3/2-1 s622s ^2S1/2 line(q) in lithium-like Ti Ⅹ Ⅹhave been recorded with a X-ray CCD camera. The experimental result shows that the wavelength resolution(λ/△ 2) is above 1000 and the elliptical crystal spectrometer is suitable for X-ray spectroscopy.
基金Supported by the National Natural Science Foundation of China (No.20476073) and the Programs of Introducing Talents of Discipline to Universities (Grant No.B06006).
文摘A self-developed laser image measurement system was established to study the behavior of bubble for- mation at a single orifice in non-Newtonian polyacrylamide(PAAm)solutions.Images of bubbles were captured by a CCD camera and volumes of bubbles were digitally analyzed online.The effects of rheological property of PAAm solution,orifice,reservoir,and gas flowrate on bubble formation were studied experimentally.It is found that the volume of bubble increases with the concentration of PAAm solution,the diameter of the orifice,and the gas flowrate,respectively,whereas little effect of reservoir is observed in experiments.
文摘Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measurement is presented in this paper. In order to eliminate the noise, the ratio of the fundamental and second-harmonic signals is used. The mathematical model of gas concentration harmonic measurement is built up.The detection result of methane concentration is also shown. Experiments have proved a sensitivity of 28×10-6.
基金National Natural Science Foundation of China under Grant No.10574022the Natural Science Foundation of Fujian Province of China under Grant Nos.2007J0002 and 2007J0197the Foundation for Universities in Fujian Province under Grant No.2007F5041
文摘We propose two schemes for preparing four-photon cluster state through cross-Kerr nonlinearity. Two coherent fields interact when they enter a nonlinear Kerr medium. If the interaction time is chosen appropriately in each Kerr medium, four-photon cluster state can be generated based on the results of two homodyne detectors in the first scheme. These schemes only use Kerr medium and homodyne measurements on coherent light fields, which can be effciently made in quantum optical laboratories. In addition, weak cross-Kerr nonlinearity is sufficient. All of the properties make these schemes feasible in experiments.
文摘Conventional multispectral space for color representation is modified by algorithm of cluster analysis and principal component analysis. Results show that the newer modified multispectral space not only keeping the structure of the original space but eliminating zero crosses as well its accuracy of color representation is higher than the conventional.
文摘The measurement principle and analysis method of natural gamma-ray spectra using Nal(T1) scintillation spectrometer are briefly described first, thed block diagrams of the HD-8004 Nal(T1) gamma-ray spectrometer. Finally, sample measurements are listed and discussed. The results are quite promising. Based on the analysis of these measurements, measures to improve the accuracy of spectrum measurement are proposed. It is well hoped that these measures call contribute to the development and application of gamma-ray spectrum measurement.
基金The project supported by the Natural Science Foundation of the Education Department of Anhui Province under Grant Nos. 2006kj070A and 2006kj057B, National Natural Science Foundation of China under Grant No. 10574001, and the Talent Foundation of Anhui University
文摘In this paper, we present a probabilistic teleportation scheme for unknown bipartite entangled state. By using linear optical elements, we convert the Bell-state measurement into separated single-qubit measurements.
文摘A precise two-degree-of-freedom measuring system (2DMS) is developed based on single-mode optical fiber, LD, cube corner retroreflector and four-quadrant photodetector (4-Q), and the simultaneous on-line measurement of lateral and vertical direction straightness errors of the linear stage is carried out. The moving part is wireless, which eliminates any errors introduced by pushing and pulling the wires. The sensitivity of the straightness error measurement can be improved by a factor of 2 with the cube corner retroreflector. This fiber-based optically aligned beam is used to establish a reference line for the straightness measurement of any mechanical system. 4-Q detector is used to receive the laser beam. A chip microcomputer is developed to conduct all data acquisition and signal processing. The beam drift influence can be removed in the greatest extent from the system. The experiments on the measurement system stability, repeatability and its comparison with the HP5528 double-frequency laser interferometer are carried out.
基金supported by the Research Projects of Huaqiao University under Grant No.07BS406
文摘In this letter, we propose a scheme of a special quantum optical Fredkin gate assisted by optical manip- ulations and postselection from the coincidence measurements, and then modify it with cross-Kerr nonlinearities to be suitable for the realization of all possible positive operator-valued measurements of bipartite polarization states. This scheme is feasible in the lab with the current experimental technology.
基金This work was supported in part by the National Natural Science Foundation of China under grant numbers 61179004,61179005 and 61401471
文摘A beam stabilization algorithm was proposed for low cost satcom-on-the-move (SOTM) to stabilize the vehicle-mounted antenna beam. The proposed algorithm utilizes the nonlinear observel to estimate the vehicle's attitude information based on inertial measurement unit. Then the estimated angles and angular velocities are used to stabilize the antenna beam. Experiment results show tha| the proposed algorithm can stabilize the antenna beam when the tracking information is available, indicating that it is competent to the SOTM system.
文摘The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental system with the method of optical heterodyne, using the refraction light beam from a prism, and made the experiment. The experimental results are in accordance with the theoretical calculation. It is very useful in some particular case, such as in Negative- Index Materials(NIM), to verify the Doppler Effect with this method.
文摘The objective of this work is to assess the radiation hazards associated gamma rays from building materials. Natural gamma rays activities of natural radionuclide represented mainly by three natural radioactive series ^238U, ^235U and ^232Th, and the primordial ^40K in the samples of building materials which consist of bricks, ceramics, marble and gypsum from different areas of eastern Algeria are measured using gamma ray spectrometry. The values of the activities of these radionuclides do not clearly reflect the radiation hazard associated with these materials. Therefore, the radium equivalent (Raeq) concentration is defined taking into account the effectiveness of these isotopes in creating the radiation hazard. Radium equivalent activities, external and internal hazard indices (Hex and Hin) are calculated from the activities of ^226Ra, ^232Th and ^40K for suitability of the materials.
文摘The authors synthesized very pure dimer phase of coroneae by simple heat-treatment and subsequent sublimation purification. It was confirmed by laser desorption/ionization mass spectroscopy measurements that pure dimer phase of coronenes can be obtained by controlling the fusing and sublimation temperatures. The crystal structure of the dimer phase was analyzed by synchrotron XRD (X-ray diffraction) experiments. It was also found that very bright red light is emitted by irradiating ultra violet light (λ = 350 nm) to the dimer phase. The external and internal quantum yields were determined to be 5.56% and 6.95%, respectively.