The effects of using overall affix and two-spot affix between the FBG and underlay on the characteristics of the pressure sensors are compared both experimentally and theoretically.It is found that overall affix can p...The effects of using overall affix and two-spot affix between the FBG and underlay on the characteristics of the pressure sensors are compared both experimentally and theoretically.It is found that overall affix can produce large nonlinear effect on the characteristics of output of the sensors.The nonlinear effect caused by the expanded spectral width mainly due to the stress birefringence and the stress grads etc.The experimental result shows that the spectral width caused by using overall affix is 0.28 nm and the linearity can have up to 1.89% of increasing by using two-spot affix.The method of two-spot affix can improve response characteristics of the sensor which is benefit to achieve wavelength demodulation and to improve measurement precision.展开更多
The measurement principle and analysis method of natural gamma-ray spectra using Nal(T1) scintillation spectrometer are briefly described first, thed block diagrams of the HD-8004 Nal(T1) gamma-ray spectrometer. Fina...The measurement principle and analysis method of natural gamma-ray spectra using Nal(T1) scintillation spectrometer are briefly described first, thed block diagrams of the HD-8004 Nal(T1) gamma-ray spectrometer. Finally, sample measurements are listed and discussed. The results are quite promising. Based on the analysis of these measurements, measures to improve the accuracy of spectrum measurement are proposed. It is well hoped that these measures call contribute to the development and application of gamma-ray spectrum measurement.展开更多
文摘The effects of using overall affix and two-spot affix between the FBG and underlay on the characteristics of the pressure sensors are compared both experimentally and theoretically.It is found that overall affix can produce large nonlinear effect on the characteristics of output of the sensors.The nonlinear effect caused by the expanded spectral width mainly due to the stress birefringence and the stress grads etc.The experimental result shows that the spectral width caused by using overall affix is 0.28 nm and the linearity can have up to 1.89% of increasing by using two-spot affix.The method of two-spot affix can improve response characteristics of the sensor which is benefit to achieve wavelength demodulation and to improve measurement precision.
文摘The measurement principle and analysis method of natural gamma-ray spectra using Nal(T1) scintillation spectrometer are briefly described first, thed block diagrams of the HD-8004 Nal(T1) gamma-ray spectrometer. Finally, sample measurements are listed and discussed. The results are quite promising. Based on the analysis of these measurements, measures to improve the accuracy of spectrum measurement are proposed. It is well hoped that these measures call contribute to the development and application of gamma-ray spectrum measurement.