Surface sediment samples collected off the Huanghe (Yellow) River mouth during the period 2007-2009 were analyzed for major and trace element concentrations. Concentrations of 16 elements were measured using X-ray f...Surface sediment samples collected off the Huanghe (Yellow) River mouth during the period 2007-2009 were analyzed for major and trace element concentrations. Concentrations of 16 elements were measured using X-ray fluorescence spectrometry. Results demonstrate that sediment grain size is the dominant factor controlling the spatial variations of elemental concentrations. Correlation and cluster analyses allowed classification of the study area into four geochemical regions: Regions Ⅰ and Ⅲare characterized by high concentrations ofAl2O3, Fe2O3, MgO, Na2O, K2O, Cr, Cu, Mn, Ni, Pb, V, and Zn, and contain fine-grained sediments with mean grain size (Mz)〈22 μm; and; Regions Ⅱ and Ⅳcontain mostly coarse-grained sediments, and are characterized by high concentrations of SiO2, Na2O, and Zr. The sediment entering the sea from the Huanghe River and its tributaries is enriched in Ca. Thus, the Ca/Al ratio was used as an indicator of the proportion of sediments in the study area that originated from the Huanghe River. Ca/Al ratios decrease from Regions Ⅰ and Ⅱ(located in the nearshore zone of the Huanghe River delta) to Regions Ⅲand Ⅳ(distributed in the offshore zone of the northern Huanghe River delta, southern and southeastern Laizhou Bay area).展开更多
A spectral calibration technique, a data processing method and the importance of calibration and re-sampling methods for the spectral domain optical coherence tomography system were numerically studied, targeted to op...A spectral calibration technique, a data processing method and the importance of calibration and re-sampling methods for the spectral domain optical coherence tomography system were numerically studied, targeted to optical coherence tomography (OCT) signal processing implementation under graphics processing unit (GPU) architecture. Accurately, assigning the wavelength to each pixel of the detector is of paramount importance to obtain high quality images and increase signal to noise ratio (SNR). High quality imaging can be achieved by proper calibration methods, here performed by phase calibration and interpolation. SNR was assessed employing two approaches, single spectrum moving window averaging and consecutive spectra data averaging, to investigate the optimized method and factor for background noise reduction. It was demonstrated that the consecutive spectra averaging had better SNR performance.展开更多
基金Supported by the National Natural Science Foundation for Young Scientists of China (No.40806026)the National Special Research Fund for the Non-Profit Sector (No.200805063,201205001)+1 种基金the 908 Project of the State Oceanic Administration, China (No.908-02-02-05)the Basic Scientific Research Operations of the First Institute of Oceanography, State Oceanic Administration (Nos.GY02-2008T28,GY02-2009G22)
文摘Surface sediment samples collected off the Huanghe (Yellow) River mouth during the period 2007-2009 were analyzed for major and trace element concentrations. Concentrations of 16 elements were measured using X-ray fluorescence spectrometry. Results demonstrate that sediment grain size is the dominant factor controlling the spatial variations of elemental concentrations. Correlation and cluster analyses allowed classification of the study area into four geochemical regions: Regions Ⅰ and Ⅲare characterized by high concentrations ofAl2O3, Fe2O3, MgO, Na2O, K2O, Cr, Cu, Mn, Ni, Pb, V, and Zn, and contain fine-grained sediments with mean grain size (Mz)〈22 μm; and; Regions Ⅱ and Ⅳcontain mostly coarse-grained sediments, and are characterized by high concentrations of SiO2, Na2O, and Zr. The sediment entering the sea from the Huanghe River and its tributaries is enriched in Ca. Thus, the Ca/Al ratio was used as an indicator of the proportion of sediments in the study area that originated from the Huanghe River. Ca/Al ratios decrease from Regions Ⅰ and Ⅱ(located in the nearshore zone of the Huanghe River delta) to Regions Ⅲand Ⅳ(distributed in the offshore zone of the northern Huanghe River delta, southern and southeastern Laizhou Bay area).
文摘A spectral calibration technique, a data processing method and the importance of calibration and re-sampling methods for the spectral domain optical coherence tomography system were numerically studied, targeted to optical coherence tomography (OCT) signal processing implementation under graphics processing unit (GPU) architecture. Accurately, assigning the wavelength to each pixel of the detector is of paramount importance to obtain high quality images and increase signal to noise ratio (SNR). High quality imaging can be achieved by proper calibration methods, here performed by phase calibration and interpolation. SNR was assessed employing two approaches, single spectrum moving window averaging and consecutive spectra data averaging, to investigate the optimized method and factor for background noise reduction. It was demonstrated that the consecutive spectra averaging had better SNR performance.